• 제목/요약/키워드: simulated canal

검색결과 92건 처리시간 0.019초

The thickness of the soft soil layer and canal-side road failure: A case study in Phra Nakhon Si Ayutthaya province, Thailand

  • Salisa Chaiyaput;Taweephong Suksawat;Lindung Zalbuin Mase;Motohiro Sugiyama;Jiratchaya Ayawanna
    • Geomechanics and Engineering
    • /
    • 제35권5호
    • /
    • pp.511-523
    • /
    • 2023
  • Canal-side roads frequently collapse due to an unexpectedly greater soft-clay thickness with a rapid drawdown situation. This causes annually increased repair and reconstruction costs. This paper aims to explore the effect of soft-clay thickness on the failure in the canal-side road in the case study of Phra Nakhon Si Ayutthaya rural road no. 1043 (AY. 1043). Before the actual construction, a field vane shear test was performed to determine the undrained shear strength and identify the thickness of the soft clay at the AY. 1043 area. After establishing the usability of AY. 1043, the resistivity survey method was used to evaluate the thickness of the soft clay layer at the failure zone. The screw driving sounding test was used to evaluate the undrained shear strength for the road structure with a medium-stiff clay layer at the failure zone for applying to the numerical model. This model was simulated to confirm the effect of soft-clay thickness on the failure of the canal-side road. The monitoring and testing results showed the tendency of rapid drawdown failure when the canal-side road was located on > 9 m thick of soft clay with a sensitivity > 4.5. The result indicates that the combination of resistivity survey and field vane shear test can be successfully used to inspect the soft-clay thickness and sensitivity before construction. The preliminary design for preventing failure or improving the stability of the canal-side road should be considered before construction under the critical thickness and sensitivity values of the soft clay.

전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성 (APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS)

  • 권오상;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.390-398
    • /
    • 2000
  • 근관형성을 위해 표준화된 근관형성기구에 비해 taper가 큰 기구들이 사용되고 있으며 이를 이용하여 형성된 근관은 taper가 큰 근관의 모양을 갖는다. 근관충전방법에 있어 근관의 크기에 적합한 1차적 gutta-percha cone을 선택할 필요가 있다. 본 연구에서는 .04 및 .06 taper의 전동화일로 형성된 근관에 열연화충전법을 위해 가장 적합한 1차 cone을 선택하기 위한 지침 마련의 목적으로, 근단공의 크기와 근관의 taper에 따른 gutta-percha cone의 근단부 근관 내 적 합도를 평가하였다. ProFile$^{(R)}$ .04 taper와 .06 taper를 이용하여 Crown down 방법으로 60개의 모형근관을 형성하였다. 표준화 gutta-percha cone, Dia-Pro ISO-.04$^{TM}$ 및 .06 gutta-percha cone, MF, F, FM 및 M 크기의 비표준화 gutta-percha cone의 근관 내 적합도는 치근단 5mm의 근관면적에 대한 gutta-percha cone의 점유 면적비(%)로 하였다. .04 taper, 25번 크기의 근관에서는 F, MF 크기의 비표준화 cone이 표준화 cone과 Dia-Pro 180-.04$^{TM}$ 보다 우수한 근관적합도를 나타내었고(p<0.05), 30번 크기의 근관에서는 F, Dia-Pro ISO-.04$^{TM}$, FM 크기의 gutta-percha cone 모두 표준화 cone보다 우수한 근관적합도를 나타내었으나(p<0.05), 35번 크기의 근관에서는 모든 gutta-percha cone 사이에 유의한 차이를 나타내지 않았다(p>0.05) .06 taper, 25번 크기의 근관에서는 사용된 비표준화 cone 모두가 표준화 cone, Dia-Pro ISO-.06$^{TM}$ 보다 나은 근관적합도를 나타내었고(P<0.05), 30번 크기의 근관에서는 표준화 cone을 제외한 나머지 gutta-percha cone에서 유의한 차이를 발견할 수 없었다. 35번 크기의 근관에는 M 크기의 비표준화 cone이 가장 우수한 근관적합도를 보이고 있는 것으로 나타났으며, FM과 Dia-Pro ISO-.06$^{TM}$ 사이에서는 유의한 차이가 나타나지 않았다(p>0.05).

  • PDF

ProTaper®의 세 가지 사용방식에 따른 성형능력 비교 (A COMPARISON OF SHAPING ABILITY OF THE THREE ProTaper® INSTRUMENTATION TECHNIQUES IN SIMULATED CANALS)

  • 김소연;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.58-65
    • /
    • 2005
  • 이 연구의 목적은 만곡이 삼한 근관에서 $ProTaper^{(R)}$를 수동으로 사용하는 방법, 엔진 구동으로 사용하는 방법, 그리고, 치관부는 엔진 구동으로 치근단부는 수동으로 사용하는 세 가지 방법의 근관 성형 능력을 비교하기 위한 것이다. 근관 길이가 170mm이고 근관 입구에서 10mm 떨어진 부위에서 만곡이 시작되며 평균 40도의 단일 만곡을 가지는 투명한 레진 블락 30개를 사용하였다. 각 군당 10개의 레진 블락을 사용하였으며, 수동형 $ProTaper^{(R)}$로 전체근관을 성형한 군형 M군, 엔진 구동형 $ProTaper^{(R)}$로 전체근관을 성형한 군을 R군, 근단부는 수동형 $ProTaper^{(R)}$를, 치관부는 엔진 구동형 $ProTaper^{(R)}$를 사용하여 성형한 군을 H군으로 하였다. 각각의 블락을 성형하고 각 군별 근관 성형시간을 기록하였다. 근관 성형전과 후의 이미지를 중첩하여 근단공으로부터의 수직 이동 거리 1, 2, 3, 4, 5 그리고 6 mm 위치에서 수평선을 긋고 총 근관폭경, 근관 만곡 내외측 삭제량, 근관의 변위, 중심 이동률을 평가하여 다음과 같은 결론을 얻었다. 1. 근관 성형시간은 R군, H군, M군 순으로 짧았고, 세 군 사이에는 유의한 차이가 있었다(p < 0.05). 2. R군이 전체적으로 삭제량이 많은 경향을 보였으나, 1, 3 mm를 제외하고는 차이가 없었다(p > 0.05). 3. 만곡내측 삭제량에 있어서는 1 mm 지점에서는 R군이, 6 mm 지점에서는 H군이 컸지만 (p < 0.05), 나머지 지점에서는 차이가 없었다. 만곡외측 삭제량은 1 mm 지점에서만 R군이 컸다 (p > 0.05). 4. H군, R군은 1, 2, 3 mm 지점, M군은 1, 2 mm 지점에서 만곡외측으로의 변위를 보였고, 그 외의 지점에서는 내측변위를 보였다. 각 군 간의 변위차이는 6 mm 지점에서 H군이 컸다(p < 0.05). 5. 근관의 중심 이동률은 6 mm 지점에서 H군이 R군에 비해 유의하게 컸지만 다른 모든 위치에서는 차이가 없었다(p < 0.05). 본 실험결과를 토대로 할 때, 각 평가 항목에서 측정 위치에 따라 약간씩 차이가 있었으나, 중심 이동률은 대부분의 위치에서 유의한 차이가 없었다. 따라서 만곡 근관을 성형시에는 세 가지 방법 중 어느 것이 더 유용하다고 보기 어렵다고 판단된다.

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong;Park, Sang-Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.215-219
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

리본 형태의 근관에서 열연화주입법의 근관벽에 대한 적합도에 관한 연구 (A COMPARISON OF THERMOPLASTICIZED INJECIABLE GUTTA-PERCHA TECHNIQUES IN RIBBON-SHAPED CANALS : ADAPTATION TO CANAL WALLS)

  • 황현숙;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.411-420
    • /
    • 2002
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shape canals were instrumented to #40 using .06 taper Profile systems. Three groups of each 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively. After resin model were kept at room temperature for 4 days, they were resected horizontally with micro-tome at 1, 2, 3, 4 and 5mm levels from apex. At each levels. image of resected surface were taken using CCD camera under a stereomicroscope at $\times$40 magnification and stored. Ratio of the area of gutta-percha was obtained by calculating area of gutta-percha cone to the total area of canal using digitized image-ana-Iyzing program. The data were collected then analyzed statistically using One-way ANOVA. The results were as follows. 1 At 1mm levels, there was no statistically significant difference in the mean ratio of gutta-percha among the groups. 2. At 2mm level, EO showed the highest mean ratio of gutta-percha (p<0.05) and there was no significant difference between LC and UF. 3. At 3, 4, 5mm levels, EO and UF had significantly greater mean ratio of gutta-percha than LC(p<0.05) and there was no significant difference between EO and UF. In conclusion, the thermoplasticized injectable gutta-percha techniques demonstrated relatively favorable adaptability to canal walls than lateral condensation technique in ribbon-shaped canals except for 1mm level.

Accuracy of Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigant

  • Shin, Hyeong-Soon;Yang, Won-Kyung;Kim, Mi-Ri;Ko, Hyun-Jung;Cho, Kyung-Mo;Park, Se-Hee;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.149-154
    • /
    • 2012
  • Objectives: To evaluate the accuracy of the Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigants, such as saline, 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine liquid, 2% chlorhexidine gel, and RC-Prep, and also to determine the electrical conductivities of these endodontic irrigants. Materials and Methods: A root perforation was simulated on twenty freshly extracted teeth by means of a small perforation made on the proximal surface of the root at 4 mm from the anatomic apex. Root ZX was used to locate root perforation and measure the electronic working lengths. The results obtained were compared with the actual working length (AWL) and the actual location of perforations (AP), allowing tolerances of 0.5 or 1.0 mm. Measurements within these limits were considered as acceptable. Chi-square test or the Fisher's exact test was used to evaluate significance. Electrical conductivities of each irrigant were also measured with an electrical conductivity tester. Results: The accuracies of the Root ZX in perforated teeth were significantly different between liquid types (saline, NaOCl) and gel types (chlorhexidine gel, RC-Prep). The accuracies of electronic working lengths in perforated teeth were higher in gel types than in liquid types. The accuracy in locating root perforation was higher in liquid types than gel types. 5.25% NaOCl had the highest electrical conductivity, whereas 2% chlorhexidine gel and RC-Prep gel had the lowest electrical conductivities among the five irrigants. Conclusions: Different canal irrigants with different electrical conductivities may affect the accuracy of the Root ZX in perforated teeth.

A comparison of thermoplasticized injectable gutta-percha technique in ribbon-shaped canals: Adaptation to canal walls

  • Hwang, Hyun-Sook;Cho, Kyuong-Mo;Kim, Jin-Woo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.587.1-587
    • /
    • 2001
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shaped canals were instrumented to #40 using. 06 taper Profile systems. Three groups of 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively.(omitted)

  • PDF

엔진구동형 NiTi 파일의 근관성형효과 비교 (A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS)

  • 김보혜;최경규;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.88-95
    • /
    • 2010
  • 이 연구의 목적은 4가지 엔진구동형 NiTi 기구의 근관성형력을 비교하는 것이다. 32개의 투명레진모형을 사용하여 파일의 단면도가 S자 형태이고 "single length"방법으로 근관성형을 시행하는 Mtwo와 crown-down 방법으로 근관성형을 하는 Profile, ProTaper Universal 및 K3로 근관성형을 하였다 (n = 8). 모든 근관은 한사람의 술자가 근단공 크기가 #30이 될 때까지 성형하였다. 기구 사용 전과 후 근관 모양을 디지털 영상을 기록하였고, 컴퓨터 영상 분석 프로그램(Expression Scanner와 Adobe Photoshop CS)으로 평가하였다. 다음과 같은 결론을 얻었다. 근첨으로부터 1, 2, 3, 4, 5, 6, 7 mm 떨어진 부위의 내측과 외측으로 삭제된 레진 양을 측정하였고, 자료는 SPSS법으로 비교 분석하였다. 1. 근관형성 시간은 Mtwo가 84.50초로 가장 짧았으며, 총 작업시간은 K3가 269.37초로 가장 길었다(p < 0.05). 2. 기구의 변형과 파절은 모든 구동형 NiTi 파일에서 발생하지 않았다. 3. 근관 내측 폭경의 변화는 Profile이 1, 2 mm 부위를 제외한 다른 부위에서 가장 적었으며, ProTaper Universal은 모든 부위에서 가장 많았다(p < 0.05). 4. 근관 외측 폭경의 변화는 Mtwo이 1 mm 부위를 제외한 모든 부위에서 가장 적었으며, Profile은 3, 4 mm 부위에서 가장 많았다(p < 0.05). ProTaper Universal와 K3는 1, 2, 6, 7 mm 부위에서 가장 많았다(p < 0.05). 5. 근관중심변위율(centering ratio)은 Profile이 1, 4, 5, 6 mm 부위에서 가장 적었다(p < 0.05). 이상의 결과, 구동성 NiTi 파일을 이용한 만곡 근관의 근관형성은 치경부는 ProTaper와 같은 삭제력이 높은 파일을 사용하는 것이 근관 입구를 효과적으로 넓히고 더 나은 taper를 형성하며, 근단부는 Profile과 같은 근관 중심 변위가 적은 파일을 사용하는 것이 근관형성 시간을 단축하고 근단부의 근관 변형(transportation)을 줄일 수 있다고 판단된다.

모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교 (COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL)

  • 하정홍;진명욱;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제35권4호
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect는 니켈-티타늄 전동 파일을 사용한 근관형성시 나타나는 현상으로 근관형성을 어렵게 한다. 이 연구의 목적은 다양한 니켈-티타늄 전동 파일들 사이의 screw-in effect를 비교하고자 하는 것이다. 본 연구에서는 여섯 가지의 다른 니켈-티타늄 전동 파일 기구들, 즉, $K3^{TM}$ (SybronEndo, Glendora, CA USA), $M_{two}$(VDW GmbH, Munchen, Germany), 삭제능이 있는 첨단을 가진 것과 삭제능이 없는 첨단을 가진 NRT (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland), 그리고 ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland)가 사용되었다. 기구가 동일한 경사도와 크기를 가지게 하기 위해, 각 기구는 경사도 0.06, size 20을 선택하였으며, ProTaper$^{(R)}$의 경우에는 이와 유사한 S2를 사용하였다. 각 기구당 10개씩 총 60개의 투명레진 블록의 모조 단일 만곡근관(REF A0177, Dentsply-Maillefer, Ballaiguez, Switzerland)에서, 전동파일의 회전속도는 분당 300회전으로 하고, 단일 pecking 동작이 되게 하여 기구조작을 하였다. 장치를 고안하여 일정한 힘의 pecking 동작을 재현하고 screw-in effect의 힘을 측정하였다. 고안한 장치의 dynamometer가 근관형성 과정동안 screw-in force를 측정하였고, 기록된 data는 고안된 소프트웨어를 이용하여 컴퓨터에 저장되었다. 데이터는 one-way ANOVA로 통계처리를 하였고, Tukey's multiple range test를 사용하여 95% 수준에서 유의성을 검정하였다. ProTaper$^{(R)}$가 가장 큰 screw-in effect를 나타내었다(p < 0.001). $K3^{TM}$$M_{two}$와 ProFile$^{(R)}$ 보다 큰 screw-in effect를 나타내었다(p < 0.001). 그러나 $M_{two}$, NRT와 ProFile$^{(R)}$ 사이에서는 유의한 차이가 나타나지 않았고(p > 0.05), 삭제능이 있는 첨단을 가진 NRT와 삭제능을 가지지 않는 첨단을 가진 NRT 사이에도 유의한 차이를 나타내지 않았다. 이상의 연구결과를 통해 볼 때, 실험에 사용된 수종의 Ni-Ti 전동파일들 사이에서 screw-in effect의 차이가 나타날 것으로 보이며. 특히, Ni-Ti 전동파일의 radial lands와 rake angle이 screw-in effect의 차이를 나타낼 수 있을 것으로 생각된다.

모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향 (Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal)

  • 성혜진;하정홍;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.380-386
    • /
    • 2010
  • 연구목적: 니켈-티타늄 금속을 근관치료기구에 도입함으로써 근관형성과정이 매우 단순화되었다. 그러나 이러한 새로운 기구는 단점도 함께 가지고 있는데 그 중 하나가 근관내로 기구가 빨려 들어가는 경향이다. 본 연구에서는 니켈-티타늄 전동파일의 경사도가 screw-in effect에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 총 20개의 S-자형 투명레진블록 (Dentsply-Maillefer) 근관에서 두 군으로 나누어 실험하였는데 Profile군에서는 0.02, 0.04 그리고 0.06 경사도의 Profile (Dentsply-Maillefer)과 0.08, 0.10 그리고 0.12의 경사도의 GT Rotary file (Dentsply-Maillefer)을 사용하였고 K3군에서는 같은 경사도의 K3 file SybronEndo)을 사용하였으며, 분당 300회전의 일정한 속도에서 단일 pecking 동작으로 기구조작을 하였다. 특수한 장치를 고안하였으며 장치내 dynamometer를 이용하여 screw-in effect를 측정하여 one-way ANOVA로 통계처리하고 Tuckey's multiple range test로 사후검정하였다. 결과: Profile 군에서는 큰 경사도의 기구가 더 큰 screw-in force를 나타내었고 (p < 0.05), K3군에서는 0.08, 0.10. 및 0.12 경사도의 기구가 0.04 경사도의 기구에 비해, 0.08 및 0.12 경사도의 기구가 0.06 경사도의 기구에 비해 더 큰 screw-in force를 나타내었다 (p < 0.05). 결론: 기구의 경사도가 클수록 screw-in force가 많이 발생하는 것으로 생각되며, 경사도가 큰 전동화일을 사용시에는 screw-in force를 억제하기 위해 더 많은 주의가 요구될 것으로 생각된다.