• Title/Summary/Keyword: simple tests

Search Result 1,236, Processing Time 0.024 seconds

A Study on the Real-time Cyber Attack Intrusion Detection Method (실시간 사이버 공격 침해사고 탐지방법에 관한 연구)

  • Choi, Jae-Hyun;Lee, Hoo-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.55-62
    • /
    • 2018
  • Recently, as the threat of cyber crime increases, the importance of security control to cope with cyber attacks on the information systems in the first place such as real-time detection is increasing. In the name of security control center, cyber terror response center and infringement response center, institutional control personnel are making efforts to prevent cyber attacks. Especially, we are detecting infringement accident by using network security equipment or utilizing control system, but it's not enough to prevent infringement accident by just controlling based on device-driven simple patterns. Therefore, the security control system is continuously being upgraded, and the development and research on the detection method are being actively carried out by the prevention activity against the threat of infringement. In this paper, we have defined the method of detecting infringement of major component module in order to improve the problem of existing infringement detection method. Through the performance tests for each module, we propose measures for effective security control and study effective infringement threat detection method by upgrading the control system using Security Information Event Management (SIEM).

Application of Gurney Flaps on a Centrifugal Fan Impeller

  • Dundi, Thomas Manoj Kumar;Sitaram, Nekkanti;Suresh, Munivenkatareddy
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • The objective of the present investigation is to explore the possibility of improving the performance of a centrifugal fan at low Reynolds numbers using a simple passive means, namely Gurney flap (GF). GFs of 1/$8^{th}$ inch brass angle (3.175 mm) corresponding to 15.9% of blade exit height or 5.1% of blade spacing at the impeller tip are attached to the impeller blade tip on the pressure surface. Performance tests are carried out on the centrifugal fan with vaneless diffuser at five Reynolds numbers (viz., 0.30, 0.41, 0.55, 0.69, $0.82{\times}10^5$, i.e., at five speeds respectively at 1,100, 1,500, 2,000, 2,500 and 3,000 rpm) without and with GF. Static pressures on the vaneless diffuser hub and shroud are also measured for each speed at four flow coefficients [${\phi}$=0.23 (below design flow coefficient), ${\phi}$=0.34 (design flow coefficient), ${\phi}$=0.45 (above design flow coefficient) and ${\phi}$=0.60 (above design flow coefficient)] with and without GF. From the performance curves it is found that the performance of the fan improves considerably with GFs at lower Reynolds numbers and improves marginally at higher Reynolds number. Similar improvements are observed for the static pressures on the diffuser hub and shroud. The effect of Reynolds number on the performance and static pressures is considerable. However the effect is reduced with GFs.

Performance and Internal Flow Condition of Mini Centrifugal Pump with Splitter Blades

  • Shigemitsu, Toru;Fukutomi, Junichiro;Kaji, Kensuke;Wada, Takashi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. Blade-to-blade low velocity regions are suppressed in the case with the splitter blades and total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.

A Spatial Index for PDA using Minimum Bounding Rectangle Compression and Hashing Techniques (최소경계사각형 압축 및 해슁 기법을 이용한 PDA용 공간색인)

  • 김진덕
    • Spatial Information Research
    • /
    • v.10 no.1
    • /
    • pp.61-76
    • /
    • 2002
  • Mobile map services using PDA are prevailing because of the rapid developments of techniques of the internet and handhold devices recently. While the volume of spatial data is tremendous and the spatial operations are time-intensive, the PDA has small size memory and a low performance processor. Therefore, the spatial index for PDA should be small size and efficiently filter out the candidate objects of spatial operation as well. This paper proposes a spatial index far PDA called MHF(Multilevel Hashing File). The MHF has simple structure for storage efficiency and uses a hashing technique, which is direct search method, for search efficiency. This paper also designs a compression technique for MBR. which occupies almost 80% of index data in the two dimensional case. We call it HMBR. Although the HMBR technique reduces the MB\ulcorner size to almost a third, it shows good filtering efficiency because of no information loss by quantization in case of small objects that occupy a major portion. Our experimental tests show that the proposed MHF index using HMBR technique is appropriate for PDA in terms of the size of index, the Number of MBR comparisons, the filtering efficiency and the execution time of spatial operations.

  • PDF

DEVELOPMENT OF PREDICTABLE STABILITY TEST FOR ASSESSMENT OF OPTIMUM LOADING TIME IN DENTAL IMPLANT

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kwon, Ji-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.628-633
    • /
    • 2008
  • STATEMENT OF PROBLEM: The application of a simple, clinically applicable noninvasive test to assess implant stability are considered highly desirable. So far there is still a controversy about correlation of various tests and implant stability. PURPOSE: In order to assess implant stability, the development of a new method is critical. It's possible to assess implant stability by calculating energy and angular momentum during implant installation. The purpose of this study is to evaluate the correlation of energy and implant stability. MATERIAL AND METHODS: Twenty three implants were installed in two different types of pig bone. Type I bone was retrieved from the distal aspect of the rib, with more cortical bone. Type II bone came from a more proximal region with less cortical components and a higher content of bone marrow and spongeous trabeculae. Insertion torque, removal torque, ISQ values and angular momentum and energy were measured. Pearson Correlation test was done to analyze the relation between RFA, maximum insertion torque, mean insertion torque, bone type, energy and removal torque. RESULTS: Type I bone showed higher removal torque than type II bone. Energy value was significantly correlated with maximum insertion torque and mean insertion torque. RFA values were related with insertion torques but the significance was lower than Energy value. CONCLUSION: Within the limitation of this study energy values were considered clinically predictable method to measure the implant stability.

The compatible non-explosive separation device for various pre-loads using the Ni-Cr wire and Kevlar rope (다양한 사전하중에 적용할 수 있는 Ni-Cr wire와 Kevlar rope를 이용한 위성 분리장치)

  • Hwang, Hyun-Su;Kim, Byung-Kyu;Jang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.2
    • /
    • pp.150-155
    • /
    • 2013
  • We present a kevlar rope based Non-Explosive Actuator(NEA) device which has simple structure and is activated by burning Ni-Cr wire. Through performance test, we find it can be operated under various pre-load by simply changing turn number of Ni-Cr wire. It shows release time of 680ms and shock level of 110G under pre-load of 6.0kN. Launching environment and space environment tests are planned to verify performance of the NEA based on European Satellite Agency test manual. Conclusively, we expect the proposed NEA can be applicable to release solar panel and fairing separation.

Clinical characteristics of children with 2009 pandemic influenza A (H1N1) admitted in a single institution

  • Park, San-In;Kim, Min-Ji;Hwang, Ho-Yeon;Oh, Chi-Eun;Lee, Jung-Hyun;Park, Jae-Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.10
    • /
    • pp.886-891
    • /
    • 2010
  • Purpose: This study aims to investigate the clinical characteristics of children diagnosed with the novel influenza A (H1N1) in the winter of 2009 at a single medical institution. Methods: Out of 545 confirmed cases of influenza A (H1N1) in children, using the real time RT-PCR method at Kosin University Gospel Hospital from September to December of 2009, 149 patients and their medical records were reviewed in terms of symptoms, laboratory findings, complications and transmission within a family. Results: Median age of subjects was 7 years (range: 2 months-18 years). New cases increased rapidly from September to reach a peak in November, then declined rapidly. Most frequently observed symptoms were fever (96.7%), cough (73.2%), rhinorrhea (36.9%) and sore throat (31.5%). Average body temperatures on the 1st, 2nd and 3rd hospital day were $38.75{\pm}0.65^{\circ}C$, $38.08{\pm}0.87^{\circ}C$ and $37.51{\pm}0.76^{\circ}C$, respectively. Complete blood counts and biochemical tests performed on the first admission day showed within the reference values in most cases. Of the 82 patients with simple chest radiography, 18 (22%) had pneumonic lesions; multi-focal bronchopneumonia in eleven, single or multi-segmental lobar pneumonia in five, and diffuse interstitial pneumonia in two patients. All of the 149 patients improved from their symptoms and discharged within 9 days of admission without any late complication. Conclusion: Children with 2009 pandemic influenza A (H1N1) at our single institution displayed nonspecific symptoms and laboratory findings, resembling those of common viral respiratory illnesses, and did not appear to develop more severe disease.

The Effect of Base Projecting Walls on the Bearing Capacity and Settlement of Shallow Foundations on Soft Ground (저면돌출벽을 이용한 연약지반상 얕은기초의 지내력 증대 효과)

  • Lim, Jongseok;Park, Seunghoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1523-1528
    • /
    • 2013
  • It is necessary to develop the simple and efficient technique that ease entry of man and equipment and take the role of foundations of temporary or small structures on the soft ground. This study intends to verify the effects on the increase of bearing capacity of base projecting walls under shallow foundations and to investigate the variance of the bearing capacity of the foundations according to the interval and length of the walls. For this, model soft ground in the chamber equipped with loading apparatus is made and the loading tests on the model foundations with base projecting walls of various intervals and lengths using the apparatus are performed with measuring the loads and settlements. The results show that the base projecting walls under shallow foundations on soft ground are effective on the increase of bearing capacity and the more the number and length of the walls the larger the effects. And, when the ratio of interval to length of the walls is 1, i.e. the shape forming the base of the foundation and the walls is square, the bearing capacity is increased by 25% and the effect is optimum.

Identification of Different Species and Dultivars of Brassica by SDS-PAGE, Isozyme and Molecular Marker

  • Mukhlesur Rahman Md.;Hirata Yutaka
    • Journal of Plant Biotechnology
    • /
    • v.7 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Eighty-five different cultivars of Brassica rapa, B. juncea, B. nap us, B. carinata, B. oleracea and hexaploid Brassica collected from Bangladesh, Japan, China and Denmark were analyzed by SDS-PAGE for seed and leaf protein variations, using esterase, acid phosphatase and peroxidase isozyme analysis. Ten polymorphic bands were identified from seed protein however no identifiable polymorphic band was found in the leaf protein. Polymorphic markers clearly distinguished the different Brassica species as well as yellow sarson (YS) and brown seeded (BS) cultivars of B. rapa. The $F_1$ cross between YS and brown seeded cultivars showed the existance of all poly-morphic bands of the respective parents. The Bangla-deshi and Japanese cultivars of B. rapa differed in the amount of seed protein. In the case of isozyme analysis, esterase showed the highest number of polymorphic bands (13) followed by acid phosphatase (9) and peroxidase (5). These polymorphic markers were very effec-tive for classification of all the species studied in this experiment. In parentage tests using isozymes, the hybridity of intra-and-interspecific crosses of almost all the seedlings could be identified from their respective cross combinations. Esterase polymorphism showed a clear differentiation between YS and BS types of B. rapa. In addition, two esterase polymorphic markers were iden ified to differentiate some cultivars of B. juncea. Segregation patterns in these two esterase bands showed a simple Mendelian monohybrid ratio of 3:1 in $F_2$, 1:1 in test cross and 1:0 in back cross progenies. No polymorphic band was identified to distinguish different cultivars of the same species by acid phosphatase or peroxidase. Polymerase Chain Reaction (PCR) was carried out with seed coat color specific marker of B. juncea. The yellow seeded cultivars produced a strong band at 0.5 kb and weak band 1.2 kb. In the addition of these two specific bands, Japanese yellow-seeded cultivars expressed two more weak bands at 1.0 kb and 1.1 kb. Where the brown seeded cultivars generated a single strong band at 1.1 kb. In segregating population, the yellow seed coat color marker segregated at a ratio 15 (brown) : 1 (yellow), indicating the digenic inheritance pattern of the trait.

An Experimental Study on the Vibration of the PWR Fuel Rod Supported by the Side-sloted Plate Springs (측면 절개된 판형 스프링으로 지지된 경수로 연료봉 진동의 실험적 고찰)

  • 최명환;강흥석;윤경호;송기남
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.798-804
    • /
    • 2003
  • One of the methods that are used to compare and verify the supporting performance of the spacer grids developed is the vibration characteristic test. A modal test in this paper is performed for a dummy rod 3,847 mm tall supported by eight New Doublet (ND) spacer grids. For the vibration test in air, nine accelerometers, one displacement sensor and one shaker are used for acquiring signals, and an I-DEAS TDAS software Is employed for analyzing the signals. Also, a finite element (FE) analysis is performed by a beam-spring simple model and a contact model simulating the contact phenomenon between the rod and the ND spring. And then, the results of the modal testing are compared with those of the FE analysis. The natural frequencies as well as the mode shapes obtained by the experiment have a greater similarity to the results by the contact model than the previous beam-spring model. In audition, for grasping whether or not the modal parameters are influenced by where shaking spot is, two kinds of tests are performed : one is for the shaker attached at the fourth span (center), the other is for the shaker at the fifth span that is one span nearer to the bottom of the rod. The latter shows higher MAC than the former Finally, the vibration displacements are measured in the range of 0.l12∼0.214 mm for the excitation force of 0.25∼0.75 N.