• Title/Summary/Keyword: simple method

Search Result 13,763, Processing Time 0.045 seconds

Adaptive Row Major Order: a Performance Optimization Method of the Transform-space View Join (적응형 행 기준 순서: 변환공간 뷰 조인의 성능 최적화 방법)

  • Lee Min-Jae;Han Wook-Shin;Whang Kyu-Young
    • Journal of KIISE:Databases
    • /
    • v.32 no.4
    • /
    • pp.345-361
    • /
    • 2005
  • A transform-space index indexes objects represented as points in the transform space An advantage of a transform-space index is that optimization of join algorithms using these indexes becomes relatively simple. However, the disadvantage is that these algorithms cannot be applied to original-space indexes such as the R-tree. As a way of overcoming this disadvantages, the authors earlier proposed the transform-space view join algorithm that joins two original- space indexes in the transform space through the notion of the transform-space view. A transform-space view is a virtual transform-space index that allows us to perform join in the transform space using original-space indexes. In a transform-space view join algorithm, the order of accessing disk pages -for which various space filling curves could be used -makes a significant impact on the performance of joins. In this paper, we Propose a new space filling curve called the adaptive row major order (ARM order). The ARM order adaptively controls the order of accessing pages and significantly reduces the one-pass buffer size (the minimum buffer size required for guaranteeing one disk access per page) and the number of disk accesses for a given buffer size. Through analysis and experiments, we verify the excellence of the ARM order when used with the transform-space view join. The transform-space view join with the ARM order always outperforms existing ones in terms of both measures used: the one-pass buffer size and the number of disk accesses for a given buffer size. Compared to other conventional space filling curves used with the transform-space view join, it reduces the one-pass buffer size by up to 21.3 times and the number of disk accesses by up to $74.6\%$. In addition, compared to existing spatial join algorithms that use R-trees in the original space, it reduces the one-pass buffer size by up to 15.7 times and the number of disk accesses by up to $65.3\%$.

Measurements of Dissociation Enthalpy for Simple Gas Hydrates Using High Pressure Differential Scanning Calorimetry (고압 시차 주사 열량계를 이용한 단일 객체 가스 하이드레이트의 해리 엔탈피 측정)

  • Lee, Seungmin;Park, Sungwon;Lee, Youngjun;Kim, Yunju;Lee, Ju Dong;Lee, Jaehyoung;Seo, Yongwon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.666-671
    • /
    • 2012
  • Gas hydrates are inclusion compounds formed when small-sized guest molecules are incorporated into the well defined cages made up of hydrogen bonded water molecules. Since large masses of natural gas hydrates exist in permafrost regions or beneath deep oceans, these naturally occurring gas hydrates in the earth containing mostly $CH_4$ are regarded as future energy resources. The heat of dissociation is one of the most important thermal properties in exploiting natural gas hydrates. The accurate and direct method to measure the dissociation enthalpies of gas hydrates is to use a calorimeter. In this study, the high pressure micro DSC (Differential Scanning Calorimeter) was used to measure the dissociation enthalpies of methane, ethane, and propane hydrates. The accuracy and repeatability of the data obtained from the DSC was confirmed by measuring the dissociation enthalpy of ice. The dissociation enthalpies of methane, ethane, and propane hydrates were found to be 54.2, 73.8, and 127.7 kJ/mol-gas, respectively. For each gas hydrate, at given pressures the dissociation temperatures which were obtained in the process of enthalpy measurement were compared with three-phase (hydrate (H) - liquid water (Lw) - vapor (V)) equilibrium data in the literature and found to be in good agreement with literature values.

The SOFA Score to Evaluate Organ Failure and Prognosis in the Intensive Care Unit Patients (중환자실에 입원한 환자의 장기부전 및 예후 평가를 위한 SOFA 점수체계의 의의)

  • Kim, Su Ho;Lee, Myung Goo;Park, Sang Myeon;Park, Young Bum;Jang, Seung Hun;Kim, Cheol Hong;Jeon, Man Jo;Shin, Tae Rim;Eom, Kwang Seok;Hyun, In-Gyu;Jung, Ki-Suck;Lee, Seung-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.329-335
    • /
    • 2004
  • Background : The Sequential Organ Failure Assessment (SOFA) score can help to assess organ failure over time and is useful to evaluate morbidity. The aim of this study is to evaluate the performance of SOFA score as a descriptor of multiple organ failure in critically ill patients in a local unit hospital, and to compare with APACHE III scoring system. Methods : This study was carried out prospectively. A total of ninety one patients were included who admitted to the medical intensive care unit (ICU) in Chuncheon Sacred Heart Hospital from May 1 through June 30, 2000. We excluded patients with a length of stay in the ICU less than 2 days following scheduled procedure, admissions for ECG monitoring, other department and patients transferred to other hospital. The SOFA score and APACHE III score were calculated on admission and then consecutively every 24 hours until ICU discharge. Results : The ICU mortality rate was 20%. The non-survivors had a higher SOFA score within 24 hours after admission. The number of organ failure was associated with increased mortality. The evaluation of a subgroup of 74 patients who stayed in the ICU for at least 48 hours showed that survivors and non-survivors followed a different course. In this subgroup, the total SOFA score increased in 81% of the non-survivors but in only 21% of the survivors. Conversely, the total SOFA score decreased in 48% of the survivors compared with 6% of the non-survivors. The non-survivors also had a higher APACHE III score within 24 hours and there was a correlation between SOFA score and APACHE III score. Conclusion : The SOFA score is a simple, but effective method to assess organ failure and to predict mortality in critically ill patients. Regular and repeated scoring enables patient's condition and clinical course to be monitored and better understood. The SOFA score well correlates with APACHE III score.

Effect of Characteristics of Grain and Flour on Color of Noodle Dough Sheet and Simple Test for Fe Content in Korean Wheat Cultivar (종실과 밀가루 특성이 국수 면대 색깔에 미치는 영향과 철 함량 간이 검정)

  • Kang, Chon-Sik;Kim, Kyeong-Hoon;Choi, Induck;Sin, Sang-Hyun;Son, Jae-Han;Cheong, Young-Keun;Lee, Choon-Ki;Park, Kwang-Geun;Park, Chul Soo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.1
    • /
    • pp.27-37
    • /
    • 2014
  • This study was carried out to characterize the color of noodle sheet made from Korean wheat cultivars, which were then evaluated on grain and flour properties, in order to enhance the breeding-line selection for noodle wheat. In particular, a rapid method was applied to investigate the effects of iron (Fe) contents on the lightness of noodle sheet for the selection of breeding-lines with high Fe contents. Wheat flour lightness of Korean wheat cultivars had a negative correlation with ash (r = -0.634, P<0.01), protein (r = -0.635, P<0.01) and total polyphenols (r = -0.493, P<0.05). The noodle sheet color showed a positive correlation with lightness, but a negative correlation with test weight, 1000 kernels weight, PPO activity and total polyphenol contents. Also, upon the wheat flour properties, the ash, protein and total polyphenol contents had a negative correlation with the lightness of noodle sheet, and this relation varied depending on the year and cultivars. The Fe content had a negative relation with the color of wheat flour and the lightness of noodle sheet, and the potassium hexacyanoferrate(II) trihydrate (PHT) test resulted in blue color. There was no correlation between Fe contents and the color of grains with PHT treatment, but after grounding the whole grains, a negative correlation was found between Fe contents and redness (r = -0.665, P<0.001) and yellowness (r = -0.658, P<0.001) of whole wheat flour with PHT treatment. On the other hand, the lightness of wheat flour with PHT treatment showed a negative relation with Fe content.

Analysis of Amperometric Response to Cholesterol according to Enzyme-Immobilization Methods (효소고정화 방법에 따른 콜레스테롤 검출용 바이오센서의 전류 감응도 분석)

  • Ji, Jung-Youn;Kim, Mee-Ra
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.731-738
    • /
    • 2011
  • Cholesterol is the precursor of various steroid hormones, bile acid, and vitamin D with functions related to regulation of membrane permeability and fluidity. However, the presence of excess blood cholesterol may lead to arteriosclerosis and hypertension. Moreover, dietary cholesterol may affect blood cholesterol levels. Generally, cholesterol determination is performed by spectrophotometric or chromatographic methods, but these methods are very time consuming and costly, and require complicated pretreatment. Thus, the development of a rapid and simple analysis method for measuring cholesterol concentration in food is needed. Multi-walled carbon nanotube (MWCNT) was functionalized to MWCNT-$NH_2$ via MWCNT-COOH to have high sensitivity to $H_2O_2$. The fabricated MWCNT-$NH_2$ was attached to a glassy carbon electrode (GCE), after which Prussian blue (PB) was coated onto MWCNT-$NH_2$/GCE. MWCNT-$NH_2$/PB/GCE was used as a working electrode. An Ag/AgCl electrode and Pt wire were used as a reference electrode and counter electrode, respectively. The sensitivity of the modified working electrode was determined based on the amount of current according to the concentration of $H_2O_2$. The response increased with an increase of $H_2O_2$ concentration in the range of 0.5~500 ${\mu}M$ ($r^2$=0.96) with a detection limit of 0.1 ${\mu}M$. Cholesterol oxidase was immobilized to aminopropyl glass beads, CNBr-activated sepharose, Na-alginate, and toyopearl beads. The immobilized enzyme reactors with aminopropyl glass beads and CNBr-activated sepharose showed linearity in the range of 1~100 ${\mu}M$ cholesterol. Na-alginate and toyopearl beads showed linearity in the range of 5~50 and 1~50 ${\mu}M$ cholesterol, respectively. The detection limit of all immobilized enzyme reactors was 1 ${\mu}M$. These enzyme reactors showed high sensitivity; especially, the enzyme reactors with CNBr-activated sepharose and Na-alginate indicated high coupling efficiency and sensitivity. Therefore, both of the enzyme reactors are more suitable for a cholesterol biosensor system.

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

The Effects of Polyampholyte on Vitrification Process for cryopreservation of Bovine Oviduct Epithelial Cell (Polyampholyte가 소난관상피세포의 초자화 동결방법에 미치는 영향)

  • Kim, Sung Woo;Lee, Jae-Yeong;Kim, Chan-Lan;Yu, Yeonhee;Lee, Sung Soo;Ko, Yeoung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.527-535
    • /
    • 2020
  • The purpose of this study was to establish a simple vitrification protocols to preserve animal cell lines derived from tissues of livestock that could be recultured. Bovine oviduct epithelial cells (BOEC) were used for the vitrification process using a 0.25 ml straw to increase cryopreservation efficiency. BOEC was cultured from the oviduct of 3.5-day estrus state, and the commercially available polyampholyte StemCell KeepTM was used as a cryoprotective agent. Using different concentrations, the viability rates of BOEC in 5, 10, 25, 50, 75, and 100% in freezing media were investigated. Survivability was determined using a differential staining technique using a trypan blue test and a CYTO-13/PI staining protocol. The viability rates of BOEC in the trypan blue test were 5.6±11.8, 12.5±7.2, 53.0±2.7, 85.1±6.9, 79.8±0.6, and 60.7±6.7% with a respective concentration of StemCell KeepTM. The viability rates in CYTO-13/PI staining were 4.6±2.5, 30.8±12.1, 58.4±2.5, 85.5±1.2, 79.8±0.6, and 71.2±1.2%, respectively. These results indicate that BOEC could be preserved with StemCell KeepTM without toxicity in a 0.25-ml straw. The optimal concentration of vitrification solution with StemCell KeepTM was determined to be 50% and can be considered as a proper preservation method for cryobanking.

A Study on Status of Utilization and The Related Factors of Primary Medical Care in a Rural Area (일부 농촌지역의 일차의료이용실태와 그 관련요인에 관한 연구)

  • Wie, Cha-Hyung
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.157-168
    • /
    • 1995
  • This study was carried out, through analyzing the annual reports(year of 1973-1993) on health status of Su Dong-Myun, and specific survey data of 332 households(Su Dong-Myun 209, Byul Nae-Myun 123), located in Nam Yang Ju-Si, Kyung Gi-Do, from July 20 to July 31, 1995, to find out more effective means for primary medical care in a rural area. The results were as fellows : 1. Number of population in Su Dong-Myun was 5,419 in 1973, 4,591(the lowest) in 1987 and 5,707 in 1995. In the composition rate of population, "0-14" of age group showed markedly decreasing tendency from 43.1% in 1975, to 19.1% in 1995, however "65 and over" markedly in creasing tendency form 5.3% in 1975 to 9.8% in 1995. 2. Annual utilization rate per 1,000 inhabitants in Su Dong-Myun showed markedly increasing tendency from 1973 to 1977 such as 343 in 1973, 540 in 1975, 900 in 1977. However, since 1979, the rate showed rapidly decreasing tendency, such as 846 in 1979, 519 in 1985, 190 in 1991 and 1993. 3. The morbid household rate per year was 53.6% of respondents and the rate per 15 days was 48.2%. In disease classification rate of morbid household per year, Arthralgia & Neuralgia was the highest rate(33.9%) and gastro-intestinal disorder(19.3%), Cough(11,9%), Hypertension(7.8%), Accident(3.2%) in next order. 4. In the utilizing facilities for Primary Medical Care, Medical facilities was showed the highest rate(58.1% of respondents) and Pharmacy and Drug Shp(33.1%), Tradition Method(4.0%) in next order. In the Medical facilities, General private clinic was showed the highest rate(34.3%) and specific private Clinic(22.3%), Hospital(19.0%), Health (Sub)center(16.3%), Nurse practitioner (3.3%), Oriental hospital and clinic(2.7%) in next order. 5. Experience rate, utilizing health subcenter was 51.8% of the respondents, and it was 55.0% in Su Dong-Myun and 46.3% in Byul Nae-Myun. In utilization times of health subcenter, times-rate showed next orders such as 1-2 times/6months(31.6%), 1-2 times/year (22.1%), 1-2 times/months(19.2%), 1-2 times/3months(15.6%). 6. In objectives, visiting Health Subcenter, Medical Care was the highest rate(59.8% of the respondents) and health control(23.3%) was in next order. In Medical Care, Primary Care by general physician was higher rate(51.1%) almost all. In the Health control, Immunization too was high rate(18.0%) in health control activities. 7. The reasons rate, utilizing health subcenter showed next order, such as distance to Medical facilities(33.0% of the respondents), Medical Cost(28.1%), Simple process of consultation (10.8%), Effectiveness of cure(7.6%), Function of primary medical care(7.0%) and Attitude of physician(6.5%). 8. In the affecting factors to utilization of primary medical facilities, medical needs was showed the highest rate(29.5% of the respondents) and medical cost(15.4%), distance to medical facilities(14.2%), traffic vehicle(14.2%) and farm work(6.9%) in next order. 9. In the priority between 'daily farm work,' and 'primary medical care', only 46.4% of respondents answered that primary health care is more important than the daily farm work The 22.6% of respondents answered 'daily farm work', and the 12.3% answered 'the equal of the both'. 10. In the criterion of medical facilities choice, medical knowledge and technical quality was showed the highest rate(56.3%), distance or time to medical facilities(10.9%), sincerity and kindness of physician(9.4%), medical cost(8.7%) and traffic vehicle(6.5%) in next order 11. In the advise for improvement of health subcenter function, the 36.1% of respondents answered that 'enforcement of medical personnel and equipment' was required, and then 'improved medical technology'(25.5%), 'good attitude of physician'(14.9%), 'improved medical system'(13.3%), 'enforced drug'(6.7%) in next order. 12. The study on affecting factors to utilization of primary medical facilities was very difficult subject to systematize the analyzed results, due to a prejudice of protocol planner, surveyer and respondent, and variety and overlapping of subject matter.

  • PDF

Implementation of An Automatic Authentication System Based on Patient's Situations and Its Performance Evaluation (환자상황 기반의 자동인증시스템 구축 및 성능평가)

  • Ham, Gyu-Sung;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.21 no.4
    • /
    • pp.25-34
    • /
    • 2020
  • In the current medical information system, a system environment is constructed in which Biometric data generated by using IoT or medical equipment connected to a patient can be stored in a medical information server and monitored at the same time. Also, the patient's biometric data, medical information, and personal information after simple authentication using only the ID / PW via the mobile terminal of the medical staff are easily accessible. However, the method of accessing these medical information needs to be improved in the dimension of protecting patient's personal information, and provides a quick authentication system for first aid. In this paper, we implemented an automatic authentication system based on the patient's situation and evaluated its performance. Patient's situation was graded into normal and emergency situation, and the situation of the patient was determined in real time using incoming patient biometric data from the ward. If the patient's situation is an emergency, an emergency message including an emergency code is send to the mobile terminal of the medical staff, and they attempted automatic authentication to access the upper medical information of the patient. Automatic authentication is a combination of user authentication(ID/PW, emergency code) and mobile terminal authentication(medical staff's role, working hours, work location). After user authentication, mobile terminal authentication is proceeded automatically without additional intervention by medical staff. After completing all authentications, medical staffs get authorization according to the role of medical staffs and patient's situations, and can access to the patient's graded medical information and personal information through the mobile terminal. We protected the patient's medical information through limited medical information access by the medical staff according to the patient's situation, and provided an automatic authentication without additional intervention in an emergency situation. We performed performance evaluation to verify the performance of the implemented automatic authentication system.

Speed-up Techniques for High-Resolution Grid Data Processing in the Early Warning System for Agrometeorological Disaster (농업기상재해 조기경보시스템에서의 고해상도 격자형 자료의 처리 속도 향상 기법)

  • Park, J.H.;Shin, Y.S.;Kim, S.K.;Kang, W.S.;Han, Y.K.;Kim, J.H.;Kim, D.J.;Kim, S.O.;Shim, K.M.;Park, E.W.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.153-163
    • /
    • 2017
  • The objective of this study is to enhance the model's speed of estimating weather variables (e.g., minimum/maximum temperature, sunshine hour, PRISM (Parameter-elevation Regression on Independent Slopes Model) based precipitation), which are applied to the Agrometeorological Early Warning System (http://www.agmet.kr). The current process of weather estimation is operated on high-performance multi-core CPUs that have 8 physical cores and 16 logical threads. Nonetheless, the server is not even dedicated to the handling of a single county, indicating that very high overhead is involved in calculating the 10 counties of the Seomjin River Basin. In order to reduce such overhead, several cache and parallelization techniques were used to measure the performance and to check the applicability. Results are as follows: (1) for simple calculations such as Growing Degree Days accumulation, the time required for Input and Output (I/O) is significantly greater than that for calculation, suggesting the need of a technique which reduces disk I/O bottlenecks; (2) when there are many I/O, it is advantageous to distribute them on several servers. However, each server must have a cache for input data so that it does not compete for the same resource; and (3) GPU-based parallel processing method is most suitable for models such as PRISM with large computation loads.