• Title/Summary/Keyword: simple joint method

Search Result 233, Processing Time 0.025 seconds

Nail Shear Performance of Structural Members with OSB (오에스비에 대한 각종 부재의 못전단성능)

  • Hwang, Kweonhwan;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.66-76
    • /
    • 2008
  • Recently, demands for the structural uses with domestic Japanese larch and SPF(spruce-pine-fir) lumber from North America have been increased. Shear properties of nailed joints that are the most simple and optimum fastening method in wooden constructions, especially in light frame construction. For the nailed joints, in North America and Japan, a number of basic and practical studies have been performed. The shear behaviors for the double nailed joint with variations of member and its direction, were examined. Shear properties of the shear specimens with SPF stud showed more remarkable variation than larch glulam and larch stud. Furthermore, the relationships between slip modulus and strength are not coincided in every case.

A Numerical Study on the Static Strength of Tubular X-Joints With an Internal Ring Stiffener (환보강 X형 관이음부의 정적강도에 관한 수치적 연구)

  • Ryu Yeon-Sun;Cho Hyun-Man
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.3
    • /
    • pp.265-275
    • /
    • 2005
  • The objective of this paper is to numerically assess the behavior of tubular X-joints with an internal ing stiffener, and to evaluate the reinforcement effect of a ring stiffener, and to establish the strength formulae. Nonlinear finite element analysis is used to compute the static strength of axially loaded tubular joints. Numerical and experimental results are in good agreement for tubular X-joints. The chord lengths of simple and ring-stiffened X-joints are suggested to reduce chord end effect. And, internal ring stiffener is found to be efficient In improving static strength of tubular X-joints. Maximum strength ratios are calculated as $1.5\sim3.5$. Regression analyses are performed considering practical size of ring stiffener and strength estimation formulae for tubular X-joints with an internal ring stiffener are proposed.

Statistical Precoder Design for Spatial Multiplexing Systems in Correlated MIMO Fading Channels (높은 안테나 상관도를 갖는 다중입출력 공간 다중화 시스템을 위한 통계적 프리코딩 기법)

  • Moon, Sung-Hyun;Kim, Jin-Sung;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3A
    • /
    • pp.223-231
    • /
    • 2011
  • It has been shown that the performance of multiple-input multiple-output (MIMO) spatial multiplexing systems is significantly degraded when spatial correlation exists between transmit and receive antenna pairs. In this paper, we investigate designs of a new statistical precoder for spatial multiplexing systems with maximum likelihood (ML) receiver which requires only correlation statistics at the transmitter. Two kinds of closed-form solution precoders based on rotation and power allocation are proposed by means of maximizing the minimum E tlidean distance of joint symbol constellations. In addition, we extend our results to linear receivers for correlated channels. We provide a method which yields the same profits from the proposed precoders based on a simple zero-forcing (ZF) receiver. The simulation shows that 2dB and 8dB gains are achieved for ML and ZF systems with two transmit antennas, respectively, compared to the conventional systems.

Decision-Making and Principle of Management in Periprosthetic Femoral Fracture after Total Hip Arthroplasty (고관절 치환술 후 삽입물의 안정성 판단과 대퇴 삽입물 주위 골절의 치료 원칙)

  • Kim, Beom-Soo;Lee, Kyung-Jae;Min, Byung-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.200-207
    • /
    • 2021
  • Periprosthetic femoral fractures remain as one of the most challenging complications following total hip arthroplasty. A thorough clinical and radiographic evaluation, precise classification, and understanding of modern management principles are essential to obtain optimal results for these fractures. The Vancouver classification system is a simple, effective, and reproducible method for the planning treatments of these injuries. The fractures associated with a stable femoral stem can be treated effectively with osteosynthesis, but periprosthetic femoral fractures associated with a loose stem require revision arthroplasty. This paper describes the principle of the treatment of patients with periprosthetic femoral fractures and how to assess the stability of the femoral stem.

A self-confined compression model of point load test and corresponding numerical and experimental validation

  • Qingwen Shi;Zhenhua Ouyang;Brijes Mishra;Yun Zhao
    • Computers and Concrete
    • /
    • v.32 no.5
    • /
    • pp.465-474
    • /
    • 2023
  • The point load test (PLT) is a widely-used alternative method in the field to determine the uniaxial compressive strength due to its simple testing machine and procedure. The point load test index can estimate the uniaxial compressive strength through conversion factors based on the rock types. However, the mechanism correlating these two parameters and the influence of the mechanical properties on PLT results are still not well understood. This study proposed a theoretical model to understand the mechanism of PLT serving as an alternative to the UCS test based on laboratory observation and literature survey. This model found that the point load test is a self-confined compression test. There is a compressive ellipsoid near the loading axis, whose dilation forms a tensile ring that provides confinement on this ellipsoid. The peak load of a point load test is linearly positive correlated to the tensile strength and negatively correlated to the Poisson ratio. The model was then verified using numerical and experimental approaches. In numerical verification, the PLT discs were simulated using flat-joint BPM of PFC3D to model the force distribution, crack propagation and BPM properties' effect with calibrated micro-parameters from laboratory UCS test and point load test of Berea sandstones. It further verified the mechanism experimentally by conducting a uniaxial compressive test, Brazilian test, and point load test on four different rocks. The findings from this study can explain the mechanism and improve the understanding of point load in determining uniaxial compressive strength.

New Method and Clinical Results of Arthroscopic Mattress-Locking Suture for Small and Medium sized Rotator Cuff Tear (관절경적 매트리스 잠김 봉합술을 이용한 회전근 개 소범위 및 중범위 파열의 새로운 치료방법과 해부학적인 결과)

  • Ko, Sang-Hun;Park, Hang-Chang;Lee, Chae-Chil;Kim, Sang-Woo;Lee, Seon-Ho;Cha, Jeo-Ryung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.2
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: To compare the clinical and radiological result of arthroscopic Mattress Locking suture repair to that of a Simple suture repair with small and medium-sized rotator cuff tears. Materials and Methods: Among 92 patients who were followed up after arthroscopic repair in patients with small and medium-sized rotator cuff tear from April 2007 to October 2010, 27 patients who took Arthroscopic Mattress Locking suture were set as group I and 65 patients who took Simple suture were set as Group II. The average age of patients were 58 years old and average follow-up period was 30 months. For analysis, VAS, ASES and KSS were used to analyze the range of joint movement and pain. And, for the image result, MRI performed after operation were evaluated. Results: The average VAS, KSS, UCLA score and ASES prior to surgery improved in the last follow-up (p<0.001), while was no difference in two groups (p>0.001). In MRI follow-up examination, the 2 cases (7.41%) of group 1 showed increased rupture lesions with improved symptoms. And the 12 cases (18.47%) of group 2 showed increased rupture lesions with improved symptoms. Retears in the group I were significant less than the group II (p<0.001). Conclusion: Comparing patients with small and medium-sized rotator cuff tear who took arthroscopic mattress locking suture repair to those who took simple suture repair after over one year follow up period, the clinical result showed no significant difference between two groups. However, Mattress Locking suture repair showed excellent radiological result compared to simple suture repair when comparing rerupture.

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Retrospective Study on Surgical Repair of 31 Canine Pelvic Fracture Cases (골반 골절의 수술적 교정을 실시한 31두 개에서의 후향연구)

  • Lee, Seung-Hoon;Park, Sung-Su;Kang, Byung-Jae;Kim, Yong-Sun;Kim, Wan-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.8-11
    • /
    • 2012
  • The results of surgical repair for pelvic factures in 31 dogs were reviewed. Lameness and weight bearing scores were used to evaluate functional recovery of the hind limbs. Simple fracture occurred in sacroiliac joint (n = 5) and ilium (n = 3). Pelvic fractures had acetabular (n = 7) and non-acetabular fractures (n = 23). Acetabular fracture cases were composed of additional surgical treatments with femoral head and neck ostectomy (FHNO) (n = 4) and only acetabular rim fixation (n = 3). Simple fractures had more rapid initial and complete recovery times than multiple fractures. Non-acetabular fracture cases (initial recovery time: 2.7 weeks, complete recovery time: 9.1 weeks) had more rapid initial and complete recovery times than acetabular fracture cases (8.4, 12.5 weeks) (p < 0.05). In addition, the cases of additional surgical treatment with FHNO (5.3, 7 weeks) had more rapid mean recovery times than surgical treatment without FHNO (11.1, 16.3 weeks). Surgical approach with FHNO in acetabular fracture was an alternative method to treat pelvic fractures in small breed dogs.

A Discussion of the Two Alternative Methods for Quantifying Changes : by Pixel Values Versus by Thematic Categories (변화의 정량화 방법에 관한 고찰 : 픽셀값 대 분류항목별)

  • Choung, Song-Hak
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.1 no.1 s.1
    • /
    • pp.193-201
    • /
    • 1993
  • In a number of areas, there are important benefits to be gained when we bring both the detection and monitoring abilities of remote sensing as well as the philosophical approach and analytic capabilities of a geographic information system to bear on a problem. A key area in the joint applications of remote sensing technology and GIS is to identify change. Whether this change is of interest for its own sake, or because the change causes us to act (for example, to update a map), remote sensing provides an excellent suite of tools for detecting change. At the same time, a GIS is perhaps the best analytic toot for quantifying the process of change. There are two alternative methods for quantifying changes. The conceptually simple approach is to un the pixel values in each of the images. This method is practical but may be too simple to identify the variety of changes in a complex scene. The common alternative is called symbolic change detection. The analyst first decides on a set of thematic categories that are important to distinguish for the application. This approach is useful only if accurate landuse/cover classifications can be obtained. Persons conducting digital change detection must be intimately familiar with the environment under study, the quality of the data set and the characteristics of change detection algorithms. Also, much work remains to identify optimum change detection algorithms for specific geographic areas and problems.

  • PDF

Study of a Mixed Finite Element Model for the Analysis of a Geometrically Nonlinear Plate (기하학적 비선형 판재 해석을 위한 혼합형 FE Model 연구)

  • Kim, Woo-Ram;Choi, Youn-Dae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1427-1435
    • /
    • 2010
  • A mixed finite element model was developed using the classical plate theory to analyze the nonlinear bending of a plate. The appropriate weight functions for the constraints integrated over the domain were determined by the Lagrange multiplier method by using the principle of minimum virtual energy; which provides the constitutive relations between force-like variables and strains. All of detail terms of element wise coefficient matrices and associate tangent matrices to be used in the Newton iterative method are presented. Then, the linear solutions of the current model and those of the traditional displacement model under the SS (simple support) boundary conditions were compared with the existing analytical solution. The post-processed images of the nonlinear results of the force-like variables are presented to show the continuity of the solutions at the joint of the element boundaries. Finally, the converged nonlinear finite element solutions of the current model are compared with those of existing traditional displacement model.