• 제목/요약/키워드: simple and R-simple

검색결과 2,174건 처리시간 0.032초

연구개발사업 우선순위 설정에 있어서 다속성효용이론(MAUT)과 계층분석과정(AHP)의 비교 (A Comparitive Study of MAUT and AHP in Priority Setting of R&B Projects)

  • 박주형;김정흠
    • 기술혁신학회지
    • /
    • 제2권2호
    • /
    • pp.201-218
    • /
    • 1999
  • The article contains an introduction of possibility of applying Multi-Attribute Utility Theory(MAUT) for priority setting of R&D projects. MAUT is compared with AHP, which is widely used recently. These two techuiques are applied to set priorities of R&D projects In a Government-funded Research Institute. Six criteria are chosen from consultation with decision makers. They are composed of 1) validity as representative projects, 2) possibility of resource mobilization, 3) spillover effect of developed technologies, 4) possibility of success, 5) scope of participation and 6) clarity of research goal. To set priorities of R&D projects, SMART(Simple MultiAttribute Rating Technique) and DVM(Difference Value Measurement) out of many MAUT methods are used to design the utility function and to determine the weights among criteria. The aggregation model is additive on the assumption the criteria are independent. AHP executes pairwise comparisons for criteria and alternatives. From the results of the case study, the results and theoretical characteristics are compared.

  • PDF

금속소재의 고변형률 영역 유동응력선도 평가 (Evaluation of Flow Stress of Metal up to High Strain)

  • 이상곤;이인규;이성윤;이성민;정명식
    • 소성∙가공
    • /
    • 제29권6호
    • /
    • pp.316-322
    • /
    • 2020
  • The flow stress curve is usually determined via uniaxial tensile or simple compression test. However, the flow stress curve up to high strain cannot be obtained using these two tests. This study presents a simple method for obtaining the flow stress curve up to high strain via FE analysis, a simple compression test, and an indentation test. In order to draw the flow stress curve up to high strain, the indentation test was carried out with the pre-stained specimen using the simple compression test. The flow stress curve of Al6110 was evaluated up to high strain using the proposed method, and the result was compared with the flow stress curve of the uniaxial tensile test of the initial material.

암환자의 삶의 질 도구개발 (Development of Quality of Life Measurement for Cancer Patients)

  • 태영숙;강은실;이명화;박금자
    • 성인간호학회지
    • /
    • 제12권4호
    • /
    • pp.741-757
    • /
    • 2000
  • This study was undertaken to develop an instrument to be used for measuring the concept of quality of life of Korean patients with cancer multidimensionary and correctly. It can contribute in holistic nursing care for Korean cancer patients and also provide and validate basic data to help oncology nurses measure the outcome of nursing intervention correctly. To develop this instrument, the researchers first estabilished a conceptual framework based on the results of qualitative data analysis and indepth interview method Development of the scale was conducted using a method in which 31 items were assessed by subjects' self report using linear analogue scales. The subjects were 79 D.M. patients, 103 patients with acute illness, and 91 cancer patients residing in Busan, Korea. Data were collected during the period from July, 24 to August 14, 2000. This instrument consisted of 31 items with a self report scale. This instrument covered 4 dimensions of cancer patients : 1) physical wellbeing 2) psychological wellbeing 3) social wellbeing and 4)spiritual wellbeing. Each item had a possible score of 10. The reliability of the scale was tested with Cronbach's alpha. Validity was evaluated by examining the relationships of this scale, Youn's Quality of Life Questionnare scores and the Simple Quality of Life scale. Two separate runs of multiple regression were used to predict scores on the Simple Quality of Life measurement. Further validation was obtained by examining the correlation between the instrument subscores and Youn's Quality of Life measurement subscore for convergence of this scale. Examination of the discriminant. power of the instrument was done using ANOVA test. The results are summarized as follows: 1. The reliability of the instrument for the quality of life was 0.8321(Cronbach's alpha.), physical wellbeing dimension 0.6343, psychological wellbeing dimension 0.6501, spiritual wellbeing dimension 0.5883. 2. This instrument had a high correlation with Youn's Quality of Life measurement(r= 0.636) in cancer patients, whereas it had a low correlation with Simple Quality of Life measurement(r=0.455) in cancer patients. In the D.M. patients, the instrument correlated with both the Youn's Quality of Life measurement and Simple Quality of life measurement(r=0.313, r= 0.407) and in the acute stage patients, the instrument had no correlation. 3. Multiple regression of individual items on the Simple Quality of Life scores accounted for 56.8% of the variance in the Simple Quality of Life measurement, whereas, Youn's Quality of Life measurement scores accounts for 31.7%. 4. The correlations collected from the three group had the same patterns of variations but especially the instrument developed in this study had higher disciminant power than that of Youn's Quality of Life Measurement.

  • PDF

120kV/70A MOSFETs Switch의 구동회로 개발 (Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit)

  • 송인호;신현석;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

ON SOME GENERALIZATIONS OF CLOSED SUBMODULES

  • DURGUN, YILMAZ
    • 대한수학회보
    • /
    • 제52권5호
    • /
    • pp.1549-1557
    • /
    • 2015
  • Characterizations of closed subgroups in abelian groups have been generalized to modules in essentially dierent ways; they are in general inequivalent. Here we consider the relations between these generalizations over commutative rings, and we characterize the commutative rings over which they coincide. These are exactly the commutative noetherian distributive rings. We also give a characterization of c-injective modules over commutative noetherian distributive rings. For a noetherian distributive ring R, we prove that, (1) direct product of simple R-modules is c-injective; (2) an R-module D is c-injective if and only if it is isomorphic to a direct summand of a direct product of simple R-modules and injective R-modules.

Ethylene glycol chitin을 이용한 진드기 H. longicornis 재조합 CHT1 단백의 키틴분해능 검정 연구 (A simple and sensitive assay for chitinolytic activity of the recombinant CHT1 proteins from the hard tick H. longicornis using ethylene glycol chitin)

  • 유명조;고조 후지사끼
    • 대한수의학회지
    • /
    • 제43권1호
    • /
    • pp.145-150
    • /
    • 2003
  • To determine effectively the chitinolytic activity of rCHT1 from the hard tick H. longicornis expressed in baculovirus-mediated Spodoptera frugtperda (Sf) 9 cells, a simple and sensitive assay system was established in solid phase using agarose gel containing ethylene glycol chitin as substrate. The various factors affecting the efficacy of the assay were also investigated. The effects of various temperature, dosages of proteins, pH of media and time courses of reaction were examined to verify the sensitivity of assay for chitinolytic activity of rCHT1 protein. It was found that the optimal reactive conditions were $37^{\circ}C$ of temperature, 12 to 15 hours of reactive times, $0.1{\mu}g$ of protein concentration and pH 5 to 7 of media. Using the assay system designed, the functional activities of H. longicornis rCHT1l protein could be evaluated simply and sensitively.

자연수 m의 일반화된 배수 판정법 (Generalized Divisibility Rule of Natural Number m)

  • 이상운
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.87-93
    • /
    • 2014
  • n/m=qm+r에서 에서 m=7인 단순한 경우에도 주어진 수 n이 m의 배수 판정법은 간단하지가 않다. 만약, m이 두 자리 수 이상이 되면 더욱 복잡해진다. 일반적인 배수 판정법으로 둔켈스 (Dunkels)법이 있지만 n이 컴퓨터로 처리하지 못하는 매우 큰 자리수인 경우 이 방법도 처리할 수 없다. 본 논문은 n과 m의 자리수와 무관하게 n(modm)=0 여부로 n이 m의 배수인지 여부를 검증하는 간단하면서도 정확한 방법을 제안한다. 제안된 방법은 $n=n_1n_2n_3{\cdots}n_k$, $m=m_1m_2{\cdots}m_l$에 대해 $r_1=n_1n_2{\cdots}n_l(mod m)$으로 설정하고, $r_i=r_{i-1}{\times}10+n_i(mod m)$, $i=2,3,{\cdots},k-1+1$로 n의 자리수를 1자리씩 감소시키는 방법을 적용하였다. 제안된 방법을 다양한 n,m 데이터에 적용한 결과 쉽고, 빠르며 정확한 몫과 나머지 값을 구할 수 있음을 보였다.

GENERATING PAIRS FOR THE HELD GROUP He

  • Ashrafi, Ali-Reza
    • Journal of applied mathematics & informatics
    • /
    • 제10권1_2호
    • /
    • pp.167-174
    • /
    • 2002
  • A group G is said to be (l, n, n)-generated if it is a quotient group of the triangle group T(p,q,r)=(x,y,z|x$\^$p/=y$\^$q/=z$\^$r/=xyz=1). In [15], the question of finding all triples (l, m, n) such that non-abelian finite simple groups are (l , m, n)-generated was posed. In this paper we partially answer this question for the sporadic group He. We continue the study of (p, q, r) -generations of the sporadic simple groups, where p, q, r are distinct primes. The problem is resolved for the Held group He.

Time-dependent stresses and curvatures in cracked R.C. sections under working loads

  • Al-Zaid, Rajeh Z.
    • Structural Engineering and Mechanics
    • /
    • 제18권3호
    • /
    • pp.363-376
    • /
    • 2004
  • The present study provides a relatively simple and accurate analytical model for the prediction of time-dependent stresses and curvatures of cracked R.C. sections under working loads. A more simplified solution is also provided. The proposed models are demonstrated by considering a numerical example and conducting a parametric study on the effects of relevant R.C. design parameters. In contrary to tension reinforcement, the compression reinforcement is found to contribute significantly in reducing tensile stresses in tension steel and in reducing the total section curvatures. The good accuracy of the proposed approximate solution opens a new vision towards a simple yet accurate model for the prediction of time-dependent effects in R.C. structures.

MININJECTIVE RINGS AND QUASI FROBENIUS RINGS

  • Min, Kang Joo
    • 충청수학회지
    • /
    • 제13권2호
    • /
    • pp.9-17
    • /
    • 2001
  • A ring R is called right mininjective if every isomorphsim between simple right ideals is given by left multiplication by an element of R. In this paper we consider that the necessary and sufficient condition for that Trivial extension of R by V, i.e. T(R; V ) is mininjective. We also study the split null extension R and S by V.

  • PDF