• Title/Summary/Keyword: similitude laws

Search Result 18, Processing Time 0.016 seconds

Applicability of Similitude Laws for 1-g Shaking Table Tests (1-g 진동대 모형시험을 위한 상사법칙의 적용성 평가)

  • 황재익;김성렬;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.141-150
    • /
    • 2004
  • Shaking table model tests were performed to reproduce the dynamic behavior of a gravity quay wall and a pile-supported wharf which were damaged during the Kobe earthquake in 1995. The results of the model tests were compared with field measurements and with the results of previous model tests. The displacements of the model quay wall were only one third of that of the prototype, whereas the deformation state of the model was similar to that of the prototype. The displacements of the model pile-supported wharf were about two thirds of that of the prototype and the locations of the maximum moments at the model pile were similar to the buckling locations of the prototype piles.

Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test (진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가)

  • Ha, Ik-Soo;Kim, Yong-Seong;Seo, Min-Woo;Park, Dong-Soon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

Failure Mechanism of Geosynthetic Reinforced Segmental Retaining Well in Tiered Configuration Using Reduced-scale Model Tests (축소 모형 실험에 의한 계단식 보강토옹벽의 파괴 메카니즘)

  • Yoo Chung-Sik;Jung Hyuk-Sang;Jeon Sang-Soo;Lee Bong-Won;Kim Ki-Yeon;Jeon Han-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.65-77
    • /
    • 2005
  • This paper investigates the failure mechanism of geosynthetic-reinforced segmental retaining walls with tiered configuration using reduced-scale model tests. The reduced scale model test set-up was established to simulate a 5 m high full-scale wall. The geometry and material properties used in the model test were determined based on the Similitude Laws. The wall failures in the model tests were successfully generated by their self weight without any surface loading and analyzed examining the digital video recordings. The failure mechanisms was examined with respect to the various offsets between the lower and upper teres and the reinforcement length. Based on the results the appropriateness of the current design guideline was discussed.

Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment (내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.721-728
    • /
    • 2006
  • Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.

Failure Mechanism of Geosynthetic-Reinforced Segmental Retaining Wall in a Tiered Configuration (계단식 보강토옹벽의 파괴 메카니즘 연구)

  • Yoo, Chung Sik;Jung, Hyuk Sang;Lee, Bong Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.4
    • /
    • pp.13-19
    • /
    • 2004
  • This paper presents the results of an investigation on the failure mechanism of geosynthetic-reinforced segmental retaining walls in tiered arrangement using reduced-scale model tests. In this laboratory model tests, a reduced scale model of the full-scale geosynthetic-reinforced wall which was constructed in Geotechnical Experimental Site at Sungkyunkwan University was used to perform a study on the failure mechanism. In order to a high degree of realism, the geometry of the wall and the material properties were selected applying Similitude Laws was used to perform laboratory model tests. And contrary to the previous failure tests with various surcharge pressures, the failure by the tired wall weight was observed. Primary variables considered in the model tests include the different offset distance between the tiers and the different reinforcement length in the lower tier and as a result of the parametric study, a different failure pattern was observed.

  • PDF

A discussion on the philosophical associations between Dongmu (東武) and Nosa (蘆沙): an approach based on the Li-Qi (理-氣) theory (동무(東武)와 노사(蘆沙)의 사상적(思想的) 연계 가능성에 대한 고찰 -이기(理氣)관계를 중심으로-)

  • Lee, Jun-Hee;Koh, Byung-Hee;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.23 no.1
    • /
    • pp.12-23
    • /
    • 2011
  • 1. Objectives: This study reviews the general theory on Li-Qi (理-氣) found in Dongmu Lee Jema (東武 李濟馬) and Nosa Gi Jeongjin (蘆沙 奇正鎭)'s works and explores the associations between their philosophical systems. 2. Methods: The main ideas on Predisposition (氣稟論) found in Dongmu's works were explored in connection with the Li-Qi (理-氣) theory and compared with the perspectives suggested by Nosa. 3. Results and Conclusions 1) Nosa criticized the "weakened supervision of Li (理)" and the "separation of Li (理) and Qi (氣)", proposing that this problem can be overcome through "mutual embracement of Li and its manifestations (理分圓融 理分相涵)". 2) When Dongmu's theory on Predisposition (氣稟論) is interpreted in terms of Li-Qi (理-氣), the Seong-Li (laws governing the organ scheme) (性理(臟理)) represents the Li (理) while the formational variations in organ scheme(臟局短長) and and the level of self-cultivation (心地淸濁) represents the Qi (氣). 3) The concept of "Diversification of Li (理之異)", bearing similarities to Nosa's Li-Qi (理-氣) theory, was introduced for the first time in Dongmu's theory on Predisposition (氣稟論), which presumably built the fundamental theories in the Sasang Constitutional Typology. 4) Within Dongmu's theory of Predisposition (氣稟論) can be found a dichotomous division of "similitude between the morally unaccomplished and the morally accomplished" in the ontological plane and "dissimilitude between the morally unaccomplished and the morally accomplished" in the axiological plane; this dichotomy is more extensive and developed compared to Nosa's attempt to find a consistent logic in both the ontological and axiological plane through a Li-Qi (理-氣) structure with Li-predominance.

Experimental Verification of a Liquid Damper with Changeable Natural Frequency for Building Response Control (고유진동수 조절이 가능한 액체댐퍼의 건물응답 제어실험)

  • Kim, Dong-Ik;Min, Kyung-Won;Park, Ji-Hun;Kim, Jae-Keon;Hwang, Kyu-Seok;Gil, Yong-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.323-330
    • /
    • 2012
  • This study deals with the experiments of liquid dampers with multi cells whose vertical tubes are divided into several square columns for easily changing natural frequencies. Shaking table test is performed to verify control effectiveness of the dampers which are installed on a building structure. To design liquid dampers, a 64-story building structure is reduced to a SDOF structure with 1/20 of similitude laws based on acceleration. The structure model is made up to adjust its mass and stiffness easily, with separate mass and drive parts. Mass parts indicate real structure's weights and drive parts indicate real structure's stiffness with springs and LM guides. Manufactured liquid damper has 18 cells and its natural frequency ranges are 0.65Hz to 0.81Hz. Shaking table test is carried out with one way excitation to compare with only accelerations of a large-scale structure and a structure installed with liquid dampers. Control performance of the liquid damper is expressed by the transfer function from shaking table accelerations to the large-scale structure ones. Testing results show that the liquid damper reduced a large-scale structure's response by tuned natural frequencies.

Comparison of 1-g and Centrifuge Model Tests for Similitude Laws (상사법칙 검증을 위한 1-g 모형실험과 원심모형실험의 비교 연구)

  • Kim Sung-Ryul;Hwang Jae-Ik;Kim Myoung-Mo;Ko Hon-Yim
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.5
    • /
    • pp.59-67
    • /
    • 2006
  • The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of the same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipation time. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.