• Title/Summary/Keyword: similar materials

Search Result 4,776, Processing Time 0.034 seconds

A Study on the Improvement Case of Cosmetic Packaging Process Using ARENA Simulation (아레나 시뮬레이션을 활용한 화장품 포장공정의 개선사례 연구)

  • Lee, Nam-Su;Lee, Jae-Yong;Jo, Eun-Hyeon;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.2
    • /
    • pp.72-78
    • /
    • 2020
  • Demand for cosmetics with functionality and eco-friendliness has increased dramatically due to recent aging, well-being trends, and increased interest in beauty. Cosmetics production in 2014 was 8,970.4 billion won, an increase of about 50% compared to 6,014.6 billion won in 2010. In the midst of this, similar companies in intense competition are pursuing differentiated strategies and innovation activities to solve quality, price and delivery problems. In particular, cosmetics packaging work is getting more difficult due to the increasing bill of materials (BOM) and difficult assembly methods. Therefore, in this study, the following problems were identified and suggestions for the improvement of the packaging Many research laboratories such as biotechnology, chemistry, and pharmaceuticals, which are undergoing various studies, are equipped with ready-made laboratory safety equipments such as bio-safety workbenches, aseptic bases, and exhaust workbenches. However, most researchers are disadvantaged in using existing safety equipment. This is because existing safety equipment can not take into account all of the unique characteristics of the research. For this reason, researchers are demanding the development of customized safety equipment that is well suited to their research needs. process of Company C, which is facing difficult situation to respond to the customer 's delivery due to the 52 - hour work week. First, we used the stopwatch to find the difficulty process in the packaging process and show ways to improve it. Second, to improve the efficiency of line balancing in the packaging process, we integrate processes, improve work methods, and perform simple automation. As a result, the prepare loss for replacement was reduced by 1 minute from 5 minutes, resulting in a 23% increase in productivity from 112 ea./hour to 137ea./ hour per person. At this time, the LOB of the packaging process was improved from 70% to 82% by operating one more production line through one person per line, total 9 people saving.

Effect of Emulsion State on the Physical Properties of Carthamus Red Pigment (유화조건이 홍화적색소의 물성에 미치는 영향)

  • Lee, Seung-Ryong;Chang, Kyu-Seob;Lee, Suk-Kun;Yoon, Hye-Hyun;Hahn, Tae-Ryong
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.54-62
    • /
    • 2000
  • This study was performed to evaluate the food technological properties according to different emulsion state of carthamus red pigment. For making emulsion, lecithin was used as an emulsifier and polyglycerol monooleate(PGMO) and polyoxyethylene sorbitan monooleate(Tween 80) were used as an assistant, and glycerin, distilled water and soybean oil were used as base materials respectively. Paprika stock solution was used for comparing carthamin on the rheological properties. The results were described as following: 1. Hunter L-value was not drastically increased until passed by 8 hours for glycerin, carthamin, and lecithin mixed sample. 2. Hunter a-value was higher at carthamin added sample than others. and b-value was higher to paprika added sample than others. 3. The viscosity, shear rate and shear stress levels in which glycerin was used as base material were higher than soybean oil or distilled water. 4. In which soybean oil was used as base material. lecithin was not affected on the rheological properties. But, in which glycerin was used. the lecithin was higher affected on carthamin than paprika. 5. The value of shear stress was increased both carthamin and soybean oil. However, that of shear rate was shown similar trends.

  • PDF

THE STUDY ON THE REMOVAL TORQUE OF THE DIAMOND LIKE CARBON COATED TITANIUM ABUTMENT SCREWS (DLC 표면 처리에 따른 임플랜트 지대주 나사의 풀림 현상에 관한 연구)

  • Koak Jai-Young;Heo Seong-Joo;Chang Ik-Tae;Yim Soon-Ho;Lee Jong-Yeop;Lee Kwang-Ryeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.128-135
    • /
    • 2003
  • Statement of problem : Implant screw loosening remains a problem in implant prosthodontics. Some abutment screws with treated surfaces were introduced to prevent screw loosening and to increase preload. DLC(Diamond Like Carbon) film has similar properties on hardness, wear resistance, chemical stability, biocompatibility as real diamond materials. Purpose : The purpose of this study was to investigate the effect of lubricant layer on abutment screw and to discriminate more effective method between soft lubricant and hard lubricant to prevent screw loosening. Material and method : In this study, $1{\mu}m$ thickness DLC was used as protective, lubricating layer of titanium screws and 3 times removal torque was measured on the abutment screws to investigate the difference in 10 coated and 10 non-coated abutment screws. Results : The results indicated that the implants with DLC coating group were not more resistant to the applied force in screw loosening. At 32Ncm, the 3 times removal torque in DLC group were $27.75{\pm}2.89,\;25.85{\pm}2.35$ and $26.2{\pm}2.57$. The removal torque in no-coated abutment screws were $27.85{\pm}4.23,\;27.35{\pm}2.81$ and $27.9{\pm}2.31$, respectively. Conclusion : The lubricant layer used in this study was Diamond Like Carbon(DLC) and it have a properties of hard and stable layer. The DLC coating layer was hard enough to prevent distortion of screws in the repeated unscrewing procedure in clinical situation. The reduced friction coefficient in hard DLC layer was not effective to prevent screw loosening.

Volume difference in upper central incisor preparation according to the changes of restorative design and marginal location (상악 중절치 삭제 시 수복 디자인과 변연부 위치에 따른 부피 변화)

  • Kim, Chong-Hyun;Park, Young-Bum;Kim, Sung-Tae;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the volumetric change of teeth after preparation for various designs and margin locations through Micro CT analysis (Skyscan 1076: SKYSCAN, Konitch, Belgium). Materials and methods: The 36 artificial teeth were used to determine reduction volume of upper central incisor. According to the restorative design these 36 teeth were divided into 4 groups and according to the marginal location each group was divided into 3 subgroups. The volume of unprepared teeth was obtained by using Micro CT and the volume of prepared teeth was obtained in the same method. The CT scanned images before and after preparation were superimposed. Results: The volume difference was significantly increased as follows: traditional laminate veneer < full laminate veneer < all ceramic crown < metal ceramic crown. One-way ANOVA and Tukey multiple comparison analyses were used to analyze the data in this study. In each group the volume difference was significantly increased as follows: 1 mm above CEJ < CEJ < 1 mm below CEJ (P<.05). The % volume difference of all ceramic crown and metal ceramic crown was 31 - 48% and that of laminate veneer was 14 - 30%. The volume difference of the traditional laminate veneer was 1/3 of that of metal ceramic crown. The full laminate (1 mm below CEJ) and all ceramic crown (1 mm above CEJ) showed a similar volume difference. Metal ceramic crown showed 13.7% more volume difference than all ceramic crown. Conclusion: There exists the difference in volumetric change according to designs of restoration and margin locations of preparation.

Color Stability of Bulk-Fill Resin Composites after Immersion in Different Media (다양한 용액에 따른 Bulk-fill 복합레진의 색조안정성 평가)

  • Kang, Sungkyoon;Song, Jihyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.353-361
    • /
    • 2019
  • The aim of this study was to evaluate the color stability of bulk-fill and conventional resin composites with respect to different storage media and thickness of composites. Filtek™ Z250 and Filtek™ Z350XT were evaluated as conventional resin composites. Filtek™ Bulk-fill Posterior Restorative and Tetric® N-Ceram Bulk Fill were evaluated as bulk-fill resin composites. CIE L*a*b* values of baseline were measured after 24 hours of storage in distilled water, and each resin composite group was divided into three subgroups and stored in distilled water, red wine, and coffee media respectively. Again after 1, 7 and 28 days of immersion, color changes (ΔE*) were calculated using the CIE L*a*b* values. The greatest ΔE* was observed in red wine for all resin composites, and the mean color changes were ranked in the increasing order of distilled water, coffee, red wine. Filtek™ Z350XT exhibited the greatest color change in all media, followed by Filtek™ Bulk-fill Posterior Restorative. Filtek™ Z250 and Tetric® N-Ceram Bulk Fill followed with similar mean color change values. According to the 2 different thicknesses of 2 mm and 4 mm of bulk-fill resin composites, there was no thickness-related difference on color changes.

Standard Measurement Procedure for Soil Radon Exhalation Rate and Its Uncertainty

  • Seo, Jihye;Nirwono, Muttaqin Margo;Park, Seong Jin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2018
  • Background: Radon contributing about 42% of annual average dose, mainly comes from soil. In this paper, standard measurement procedures for soil radon exhalation rate are suggested and their measurement uncertainties are analyzed. Materials and Methods: We used accumulation method for estimating surface exhalation rate. The closed-loop measurement system was made up with a RAD7 detector and a surface chamber. Radon activity concentrations in the system were observed as a function of time, with data collection of 5 and 15-minute and the measurement time of 4 hours. Linear and exponential fittings were used to obtain radon exhalation rates from observed data. Standard deviations of measurement uncertainties for two approaches were estimated using usual propagation rules. Results and Discussion: The exhalation rates (E) from linear approach, with 30 minutes measurement time were $44.8-48.6mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.14-2.32atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with relative measurement uncertainty of about 10%. The contributions of fitting parameter A, volume (V) and surface (S) to the estimated measurement uncertainty of E were 59.8%, 30.1% and 10.1%, in average respectively. In exponential fitting, at 3-hour measurement we had E ranged of $51.6-69.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.46-3.30atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with about 15% relative uncertainty. Fitting with 4-hour measurement resulted E about $51.3-68.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.45-3.25atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with 10% relative uncertainty. The uncertainty contributions in exponential approach were 75.1%, 13.4%, 8.7%, and 2.9% for total decay constant k, fitting parameter B, V, and S, respectively. Conclusion: In obtaining exhalation rates, the linear approach is easy to apply, but by saturation feature of radon concentrations, the slope tends to decrease away from the expected slope for extended measurement time. For linear approach, measurement time of 1-hour or less was suggested. For exponential approach, the obtained exhalation rates showed similar values for any measurement time, but measurement time of 3-hour or more was suggested for about 10% relative uncertainty.

Interior surface treatment guidelines for classrooms according to the acoustical performance criteria (학교 교실의 음환경 기준에 따른 실내마감 방안)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.92-101
    • /
    • 2016
  • There are many results in which acoustical conditions of a classroom play an important role for studying effects and academic achievement of students. However, there are very few guidelines or design proposals which could make appropriate acoustic environment when classrooms are built or renovated. The present study suggests various design proposals satisfying acoustic standards of classrooms based on theoretical calculation and acoustic field experiments. At first, minimum area of sound absorption was calculated which is required to satisfy the acoustic standard for domestic middle and high schools. Also, room acoustic measurements were carried out in order to investigate the acoustic performance of an existing classroom by changing interior finishing materials on ceiling and rear walls. As a result, it was revealed that reverberation time standard below 0.8 s can be acquired even if there is no sound absorption on ceiling which is a general practice executed in Korea. Specially, it was found that if partial area of ceiling would be treated as reflective with the ratio of sound absorption and reflection as 2:1, almost similar acoustic parameters of $C_{50}$, $D_{50}$, RASTI (Rapid Speech Transmission Index) and higher sound levels could be acquired in comparison with the case of entire sound absorption on ceiling.

High Temperature Behavior of Liquid Diffusion Bonded Joints of Mar-M-247 Alloy (Mar-M-247 합금의 액상확산접합부 고온 특성 거동)

  • Son, Myungsook;Ahn, Jongkee;Lee, Dongyeop;Kim, Jungi;Kang, Sukchul;Kim, Hongkyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.248-250
    • /
    • 2017
  • The Mar-M-247 alloy is one of the most widely used materials for gas turbine components in aerospace filed and it shows excellent high temperature strength properties. Hot section parts, such as turbine nozzle and blade, are difficult to manufacture because of their complicated shape. So, the joining process usually applies to them. In this study, the high-temperature behavior of Mar-M-247 alloy at liquid diffusion bonding was investigated. Thus, we performed the diffusion bonding at $1,121^{\circ}C$ for 7 minutes, and observed changes in high temperature strength. As a result, the strength of the bonded specimens decreased by about 70% at $649^{\circ}C$, 60% at $825^{\circ}C$, and 45% at $1,000^{\circ}C$ compared to the base metal. As a result of observing the strength change with bonding time, the specimen bonded for 720 minutes showed a similar strength with the base metal at $649^{\circ}C$. Inferring this result, the joint is considered to be the one-body part.

  • PDF

The effects of Naetakchunkeum-san on the Allergic Contact Dermatitis induced by DNCB (내탁천금산(內托千金散)이 DNCB로 유발된 알레르기성 접촉피부염에 미치는 영향)

  • Kim, Joon-Jeong;Kim, Hee-Taek
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.1
    • /
    • pp.46-61
    • /
    • 2009
  • Background and Objectives : Allergic Contact Dermatitis is the disease affected by industrialization. The more industrialization advanced, the more materials that could induce the allergic contact dermatitis have been increased. Therefore in oriental medicine, various studies have been performed. The objective of this study is to investigate the effects of Naetakchunkeum-san on the Allergic Contact Dermatitis induced by 2,4-dinitro-chlorobezene(DNCB). Meterial and Methods : Twenty eight mice were divided into four groups ; normal, control, experimental group A and B. Control and experimental group were induced allergic contact dermatitis by DNCB. Experimental group A was orally administered the Naetakchunkeum-san and experimental group B was orally administered the prednisolone. In this study, ear thickness measurement, observation auricle microphotograph, Myeloperoxidase(MPO) activity measurement, Reverse transcription-polymerase chain reaction(RT-PCR) analysis of the mRNA level of $TNF-\alpha$, $IL-1\beta$, $INF-\gamma$ were performed on these four groups. In addition, the effect of Naetakchunkeum-san on cell viability and the effect of Naetakchunkeum-san on the compound 48/80-induced histamine release from HMC and RPMC were measured, Results : 1. In contact hypersensitivity assay, experimental group A and B showed decreased ear thickness compared with control group, 2. In experimental group A, pathological lesion of dermatitis were alleviated. In addition, the numbers of infiltrated cells were reduced, and cleft was not shown compared with control group, In experimental group B, similar results were shown. 3. There was a significant increase in MPO activity in control group compared with normal group, Experimental group A and B significantly inhibited the increase in MPO activity compared with control group. 4, The level of expression of $TNF-\alpha$, $IL-1\beta$, $INF-\gamma$ in experimental group A and B were significantly lower than those in control group. As the internal control, cyclophilin mRNA was also reverse-transcribed and amplified. 5, In MTT assay, there were no statistically significant differences in 100 ${\mu}g/ml$, 200 ${\mu}g/ml$, 500 ${\mu}g/ml$, 1000 ${\mu}g/ml$ Naetakchunkeum-san treated group from 0 ${\mu}g/ml$ Naetakchunkeum-san treated group as determined by the Tukey test. 6. Naetakchunkeum-san dose-dependently inhibited the compound 48/80-induced histamine release from both HMC and RPMC. Conclusions : According to above experiments, Naetakchunkeum-san may be applied to allergic contact dermatitis.

  • PDF

Stability of Nano-emulsions prepared upon Change of Composition (조성변화에 따라 제조된 나노에멀젼의 안정성)

  • Cho, Wan Goo;Kim, Eun Hee;Jeon, Bong-Ju;Cha, Young-Kweon;Park, Seon-Ki
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • Applications of nano-emulsion for cosmetics as a means of promoting dermal absorption have been the subject of interest. In this study, the stability of nano-emulsions prepared by low-energy emulsification method and varying the composition of raw materials was investigated. By measuring the particle size of the nano-emulsion against time, the stability of nano-emulsions prepared by adding polyol to water phase was increased significantly compared with the nano-emulsions prepared by adding polyol to ethanol phase. The speed of adding ethanol phase to water phase did not have a significant impact on the particle size and stability. Depending on the type of oil, stability was not affected. However, there would be a correlation between the initial size of the nano-emulsion droplets and the molecular weight and polarity of the oil. Stability and the initial particle size according to the type of polyols showed a similar trend except 1,2 hexanediol. The initial droplet size was affected by the concentration of surfactant and oil. However, the initial droplet size did not change against time. Concentration of ethanol was observed to have a significant impact on the initial particle size and stability.