• Title/Summary/Keyword: similar material

Search Result 3,185, Processing Time 0.032 seconds

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface

Studies on the Preparation of Improved Soysauce Kojis (메주제조개선(製造改善)에 관(關)한 연구(硏究))

  • Kim, Z.U.;Cho, M.J.;Kim, S.S.
    • Applied Biological Chemistry
    • /
    • v.11
    • /
    • pp.35-41
    • /
    • 1969
  • In order to determine proper ratio of wheat to soybean of soysauce koji material for Korean people's taste, sensory evaluation for the soysauces made from soysauce kojis with various above-mentioned ratio and analysis of chemical components through the brewing period of six months were carried out. The results obtained were summarized as follows: 1. The specific gravity of all the soysauces increased gradually as the time passed and had maximum values in two months with nearly constant values thereafter. Concerning soybean/wheat-ratio, generally, the higher soybean/wheat-ratio, the lower specific gravity was observed but when this ratio was higher than 10 : 6, the gravity was on the similar levels. 2. The solid material in all the soysauces increased in the earlier stage and there were no significant differences among the treatments but soysauces without wheat had a little low content. 3. The lesser amount of wheat as raw material was, the higher contents of total nitrogen were and the contents of total nitrogen in the every ratio of raw material increased parallely as the mash ages. 4. The amino-nitrogen levels were found to have the simllar tendency to total nitroghen levels. 5. The reducing sugar content was higher in the soysauces with more-wheat and increased rapidly up to the maximum level in two months and then the higher wheat/soybean-ratio was, the slower decrease of the sugar content was observed. 6. The maximum total acidity was observed in the soysauces with 10; 4-6 (soybean/wheat-ratio) and increased similary in all the soysauces throughout the period. 7. According to the sensory evaluation, the short (2-3 months) fermented soysauces showed best taste when soybean/wheat-ratio was 10 : 8 and 10 : 6 if diluted, but in long (4-6 months) fermented soysauces it was 10 : 6 and 10 : 4 if diluted.

  • PDF

A Study on the Reinforcement Effect Analysis of Aging Reservoir using Grout Material recycled Power Plant Byproduct (발전부산물을 재활용한 그라우트재의 노후 저수지 보강효과 분석에 관한 연구)

  • Seo, Se-Gwan;An, Jong-Hwan;Cho, Dae-sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.2
    • /
    • pp.23-33
    • /
    • 2021
  • In Korea, many reservoirs have been built for the purpose of solving the food shortage problem and supplying agricultural water. However, the current 75.6% of the reservoirs are in serious aged as more than 50 years have passed since the year of construction. In the case of such an aging reservoir, the stability due to scour and erosion inside the reservoir is very reduced, and if concentrated rainfall due to recent abnormal weather occurs, the aging reservoir may collapse, leading to a lot of damage to property and human life. Accordingly, each agency that manages aging reservoirs uses Ordinary Portland Cement (OPC) as an injection material and applies the grouting method. However, in the case of OPC, it may deteriorate over time and water leakage may occur again. And there are environmental problems such as consumption of natural resources and generation of greenhouse gases. So, there is a need to develop new materials and methods that can replace the OPC. In this study, an laboratory test and analysis were performed on the grout material developed to induce a curing reaction similar to that of OPC by recycling power plant byproduct. In addition, test in the field such as electric resistivity survey, Standard Penetration Test (SPT), and field permeability test were performed to analyzed to reinforcement effect and determine the possibility of using instead of OPC. As a results of the test, in the case of recycled power plant byproduct, the compressive strength was 2.9 to 3.2 times and the deformation modulus was 2.3 to 3.3 times higher, indicating that it is excellent in strength and can be used instead of OPC. And it was analyzed that the N value of the reservoir was increased by 1~2, and the coefficient of permeability (k) decreased to the level of 8.9~42.5%. showing sufficient reinforcing effect in terms of order.

Effect of pH on Phase Separated Anaerobic Digestion

  • Jung, Jin-Young;Lee, Sang-Min;Shin, Pyong-Kyun;Chung, Yun-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.456-459
    • /
    • 2000
  • A pilot scale experiment was performed for a year to develop a two-phase anaerobic process for piggery wastewater treatment (COD: 6,000mg/L, BOD: 4,000mg/L, SS: 500mg/L, pH 8.4, alkalinity 6,000mg/L). The acidogenic reactor had a total volume of 3㎥, and the methanogenic reactor, an anaerobic up-flow sludge filter, combining a filter and a sludge bed, was also of total volume 3㎥(1.5㎥ of upper packing material). Temperatures of the acidogenic and methanogenic reactors kept at 20$^{\circ}C$ and 35$^{\circ}C$, respectively. When the pH of the acidogenic reactor was controlled at 6.0-7.0 with HCl, the COD removal efficiency increased from 50 to 80% over a period of six months, and as a result, the COD of the final effluent fell in the range of 1,000-1,500 mg/L. BOD removal efficiency over the same period was above 90%, and 300 to 400 mg/L was maintained in the final effluent. The average SS in the final effluent was 270 mg/L. The methane production was 0.32㎥ CH$_4$/kg COD(sub)removed and methane content of the methanogenic reactor was high value at 80-90%. When the pH of the acidogenic reactor was not controlled over the final two months, the pH reached 8.2 and acid conversion decreased compared with that of pH controlled, while COD removal was similar to the pH controlled operation. Without pH control, the methane content in the gas from methanogenic reactor improved to 90%, compared to 80% with pH control.

  • PDF

A Study on Humid Control Characteristics of Alkaline Desiccants (알칼리성 용해제의 조습특성에 관한 연구)

  • Hong, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.169-173
    • /
    • 2010
  • Many salts have the ability to attract and remove water vapor from the surrounding environment. The ability of each salt to remove water vapor is based on the flow rate and temperature of air in surrounding. The objective of this study was toinvestigate the humid control characteristics in air-water system by using a desiccants. The aim is to asses the influence of three parameters on the humid control process which are air volume rate, air temperature and desiccant amount. Humidity control materials which consist of K (potassium) or Na (sodium) have been synthesized by the aqueous process. The humidity control properties of materials have been also investigated. Experiment results are as following. Thermal characteristics of desiccants showed similar properties regardless of processing condition. The experiments were examined by using artificial air-water system (humidity : 70~93%, air volume rate : $0.22{\sim}0.69m^3/s$). The results showed that the Na-type desiccant was an effective material. It was found that dew point increased with air volume rate, and the humidity change in humid control process was depended on desiccants amount.

Electrical Resistivity Response Due to the Variation of Embankment Shape and Reservoir Level (제체형태와 수위에 따른 전기비저항 반응 연구)

  • Oh, Seok-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.214-220
    • /
    • 2008
  • The distortion effect of electrical response for two-dimensional (2-D) DC resistivity method was verified in terms of 2-D inversion result of synthetic data obtained by three-dimensional (3-D) modeling, which is frequently applied to assess the safety of center core-type fill dam structure. The distortion effect is due to 2-D interpretation for 3-D structure. By the modeling analysis, we found that the water level is correctly described in the resistivity section around the middle part rather than each end side of the embankment due to the 3-D terrain effect, when the material of the embankment is assumed as horizontally uniform. And when we set the slope of outer rock fill part as uniform. the sharper the slope of the center core is, the more similar the resistivity section reflects. On the other hand, when the slope of the rock fill is steep, the resistivity section shows the water level at lower position than the real one, and the 3-D distortion effect at the end side of the embankment was enhanced.

The Characteristic Analysis of White Organic Light Emitting Diodes with Two-wavelength Materials at Emitting Layer (발광층에 2파장 재료를 갖는 백색 유기발광소자의 특성분석)

  • Kang, Myung-Koo;Shim, Ju-Yong;Oh, Hwan-Sool
    • 전자공학회논문지 IE
    • /
    • v.45 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the white organic LED with two-wavelength was fabricated using the NPB of blue emitting material and a series of orange color fluorescent dye(Rubrene) by vacuum evaporation processes. The structure of white OLED was ITO/NPB$(200{\AA})$NPB:Rubrene$(300{\AA})$/BCP$(100{\AA})/Alq_3(100{\AA})/Al(1000{\AA})$ and the doping concentration of Rubrene was 0.75 wt%. We obtained the white OLED with CIE color coordinates were x=0.3327 and y=0.3387, and the maximum EL wavelength of the fabricated white organic light-emitting device was 560 nm at applied voltage of 11 V, which was similar to NTSC white color with CIE color coordinates of x=0.3333 and y=0.3333. The turn-on voltage is 1 V, the light-emitting him-on voltage is 4 V. We were able to obtain an excellent maximum external quantum efficiency of 0.457 % at an applied voltage of 18.5 V and current density of $369mA/cm^2$.

Fabrication of AC4A/$SiC_w$composite by squeeze casting(II) (용탕단조법에 의한 AC4A/$SiC_w$복합재교 제조에 관한 연구(ll)-가압력 및 시효특성-)

  • Mun, Gyeong-Cheol;Lee, Chun-Hui
    • Korean Journal of Materials Research
    • /
    • v.3 no.6
    • /
    • pp.606-613
    • /
    • 1993
  • This was studied about aging characteristic of AC4A/$SiC_{w}$ 10-30v/o reinforced composite. Aging hardenability was decreased $SiC_{w}$ 30% > 10% > 20%. Aging hardening of T6 treatmented composite was higher absolute value than AC4A I/M material. And this results indicated initial hardening phenomenon according to increase $SiC_{w}$ volume fraction. Reinforced effect by pressure was the same effect as before aging treatment and the best condition pressure at 75MPa. Similar to reinforced effect according to $SiC_{w}$ volume fraction was 30 % > 10 % > 20 %. In case of pressure is low, whisker is not break the same time press with base metal after wetting. After it is wetting with base metal, a part transformed or wetting part break and whisker maintain original shape or a part transformed on the otherhand, in case of pressure is high, whisker is break in same time it was not against pressure and whisker's shape is near a polygon or spherical shape.

  • PDF

An Experimental Study on Transfer Length of Domestic CFRP Tendon (국내 CFRP 긴장재의 전달길이에 관한 실험적 연구)

  • Jung, Woo-Tai;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.303-310
    • /
    • 2009
  • CFRP(carbon fiber reinforced polymer) tendons can be used as an alternative to solve the corrosion problem of steel tendons. Material properties of CFRP tendons such as bond strength, transfer length, and development length should be determined in order to apply to concrete structures. First of all, in case of application for pretension concrete members with CFRP tendons, transfer length is an important factor. A total of 9 beams have been cast to determine transfer length and development length of domestic CFRP tendon in this paper. Test results revealed that transfer length of the prestressing 25% and 50% are 34D, 55D respectively. Also, transfer length has increased as the prestressing force has increased. A change was observed in transfer length of developed CFRP tendon after 9 weeks. ${\alpha}_t$ of developed CFRP tendon was 2.3 similar to the steel strand.

New Methods of Measuring Magnetization and Coercivity by Torque Magnetometer (토크마그네토미터를 이요한 자화 및 보자력측정의 새로운 방법)

  • Heo, Jin;Sin, Seong-Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.263-267
    • /
    • 1992
  • We have developed new techniques to measure the magnetization and coercivity of a uniaxial magnetic material using a torque magnetometer. The magnetization could be measured from the slope of the linear region in a plot of the torque ${\tau}/H$ versus the applied field H, when the direction of the applied field was normal to the uniaxial orientation. While, the coercivity could be obtained by taking the value of applied field where the torque was zero, when the direction of the applied field was $(180+{\delta})$ degrees from the uniaxial orientation. The techniques were applied to determine the magnetizations and coercivities of several Co /Pd multilayer thin films and the results were confirmed to be similar within a 2 % difference to those obtained by a vibrating sample magnetometer.

  • PDF