• Title/Summary/Keyword: similar material

Search Result 3,185, Processing Time 0.037 seconds

Laboratory Experiments of a Ground-Penetrating Radar for Detecting Subsurface Cavities in the Vicinity of a Buried Pipe (매설관 주변 지하 공동 탐지를 위한 지하 탐사 레이다의 모의실험)

  • Hyun, Seung-Yeup
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • In this paper, a feasibility on a ground-penetrating radar for detecting subsurface cavities near buried pipes has been investigated. The experimental setup was implemented by employing an impulse ground-penetrating radar system, a xy Cartesian coordinate robot, an underground material filled tank, a metal pipe and a simulated cavity model. In particular, the simulated cavity model was constructed by packing Styrofoam chips and balls, which have both similar electrical properties to an air-filled cavity and a solid shape. Through typical three experiments, B-scan data of the radar have been acquired and displayed as 2-D gray-scale images. According to the comparison of B-scan images, we show that the subsurface cavities near the buried pipes can be detected by using the radar survey.

AN ANALYSIS AND MANAGEMENT OF FRACTURED IMPLANTS (파절된 임프란트 고정체의 분석과 처치)

  • Han Chang-Hyun;Kim Sung-Hyun;Hee Seong-Joo;Ku Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.25-36
    • /
    • 2001
  • Among the numerous factors contributing to implant failure, the most common are infection, failure of proper healing and overload. These factors may occur combined. Implant fractures are one of the complications resulting from overload. Implant fracture is not a common feature, but once it occurs it causes very unpleasant circumstances for the patient as well as for the practitioner. Only few studies have been reported regarding this subject. Thus, little is known about its solutions. It is important that analyzing reasons for implant fracture and finding appropriate solutions. Factors leading to implant fracture are design, material defects, nonpassive fit of prosthetic framework and biomechanical overload. Previous studies have reported that implant fractures ares associated with marginal bone loss and occur mostly in the posterior regions and that most patients showing parafunctional habits also have implant fracture. Abutment and gold screw loosening or fracture were also observed in some of the cases previous to implant fracture. Similar observations were seen in our hospital as well. The following cases will present implant fracture cases which have been successfully treated regarding function and biomechanics. This was achieved by means of using increased number of futures, increasing fixture diameter and establishing proper occlusion.

  • PDF

Chemical Composition of Salicornia Herbacea L.

  • Min, Jin-Gi;Lee, Doo-Seog;Kim, Tae-Jin;Park, Jeong-Heum;Cho, Tae-Yong;Park, Dong-In
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.1
    • /
    • pp.105-107
    • /
    • 2002
  • To get basic data for the utilization of S. herbacea L. as a raw material in food and Chinese herbs, chemical compositions of its leaves, stem and root were investigated. Leaves had the highest level of moisture and the lowest bevel of total sugar. The crude protein and crude lipid contents of the stem were similar to those of the root. Crude ash and salt contents (dry basis) in leaves were considerably higher than those of the stem and root. Total amino acid contents of leaves, stem and root were 1,270 mg/100 g, 1,525 mg/100 g, and 1,569 mg/100 g, respectively. Although the amino acid compositions of loaves, stein, and root were different, their major amino acids were glutamic acid, leuicine, isoleucine and aspartic acid. The rich minerals in leaves, stem and root were Na, K and Ca.

The Analysis of Fundamental Property for Developing High Performance Concrete of Ternary System (3성분계 고성능 콘크리트 개발을 위한 기초 특성 분석)

  • Park, Byung-Kwan;Choi, Sung-Yong;Kim, Soo-Yung;Kim, Bok-Kyu;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.805-808
    • /
    • 2008
  • This study analyzed the basic characteristics of concretes to develop 3 ingredients high performance concrete that displaced BS and FA, and the results are as follows. As part of fresh concrete characteristics, the flow was shown more increase than OPC with increase in admixture material displacement rate, and air amount tended to decrease with increase in admixture displacement rate. As hardened concrete characteristics, compressive strength decreased below OPC at early age with increase in BS and FA displacement rate, however at age 28 days, it was similar to OPC or increased above that. Particularly, at B30F15 with age 28 days, its compressive strength was about 15% higher than OPC

  • PDF

Critical State Parameters of a High Compressible Jeju Sand (압축성이 큰 제주해사의 한계상태정수)

  • Lee, Moon-Joo;Hong, Sung-Jin;Choi, Young-Min;Kim, Min-Tae;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1383-1390
    • /
    • 2009
  • This study conducted a series of drained triaxial test in order to determine the critical state parameters of a high compressible Jeju sand. Jeju sand is classified into mixed sand containing both siliceous and calcareous materials and has high extreme void ratios due to the angularity of grains and the intra-particle voids of hollow particles. It is observed that the behavior of Jeju sand is similar to that of general calcareous sand. The friction angle of Jeju sand at critical state gradually decreases with increasing the mean effective stress. Test result shows that the particle crushing resulted from stress during shear causes the reduction of void ratio at critical state.

  • PDF

Study of Frequency Response Characteristics in Microphone Used by Optical Sensor

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.128-133
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in microphone using optical sensor, acousto-optic sensor system has been implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point has also been determined by measuring the response characteristics. The choosing the point, which has maximum linearity and sensitivity has changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement /analysis program, "Smaart Live" and "USBPre", which are based on PC, and compared the result from an existing capacitance microphone. The measured optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 4 kHz at up to 3 dB.

Highly efficient, long living white PIN-OLEDs for AM displays

  • Murano, Sven;Vehse, Martin;He, Gufeng;Birnstock, Jan;Hofmann, Michael
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.239-244
    • /
    • 2007
  • Highly efficient and stable white PIN OLED structures have been developed with a focus on possible AM display applications. Due to the use of the novel air-stable Novaled n-dopant material NDN26, the mass production compatibility of the PIN approach is improved. With both a conventional n-dopant, NDN1, and a novel air-stable n-dopant, NDN26, similar performance in efficiency and lifetime are reached. Based on highly a stable red fluorescent emitter system, the Novaled PIN approach allows for reaching ultra-long lifetimes of 1,000,000 hours at a brightness of $1,000\;cd/m^2$, both for top and for bottom emission layouts. Furthermore, inverted PIN structures for a possible use in a-Si backplane applications for AM displays are shown. With a phosphorescent green emitter system it could be demonstrated that for bottom and inverted as well as non-inverted top emission, a brightness of $1,000\;cd/m^2$ can be reached at below 3 V. In addition to low operating voltages and long lifetimes, PIN OLEDs also enable for device structures with extremely low operating voltage drifts, a feature of increasing importance for future AM display developments.

  • PDF

Characteristics of Motion-blur Free TFT-LCD using Short Persistent CCFL in Blinking Backlight Driving

  • Han, Jeong-Min;Ok, Chul-Ho;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.166-169
    • /
    • 2007
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive TN-LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by counting between on time and off time for video signal input during 1 frame (16.7 ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by CCFL blinking drive and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

An Experimetal Study on Strength Characteristics of Mass Concrete Cast with High-Strength Concrete for Precast Application. (프리캐스트 콘크리트 적용을 위한 고강도 매스 콘크리트 부재의 강도 특성에 관한 실험적 연구)

  • Park, Jo-Hyun;Kim, Sung-Jin;Paik, Min-Su;Lee, Seung-Hoon;Park, Byung-Keun;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.49-52
    • /
    • 2007
  • Recently, as architectural concrete structures become high-rise and megastructured, concrete become high-strengthened and, by ensuring products of more stability, air compression and rationalization of construction are required. In general, product management test of precast concrete member, specimen for management cured in the same condition with precast concrete member is substitutively used for strength test. However, large cross-sectional precast concrete members such as columns show large temperature increase in manufacturing process not only by external heating but also by concrete itself's hydration heating. Therefore, it is expected that specimen for management to predict strength and compression strength of precast concrete member shows different temperature history and strength characteristics. Concerning this, in order to suggest temperature history and strength characteristics of high strength mass concrete suitable for precast concrete application, this study comprises the inclusive investigations on the relations between management specimen with similar temperature history and core strength, and the strength characteristics per member cross-section dimensional value and per water-bonding material ratio value.

  • PDF

Electrochemical Properties of LiNi0.8Co0.16Al0.04O2 and Surface Modification with Co3(PO4)2 as Cathode Materials for Lithium Battery

  • Ryu, Kwang-Sun;Lee, Sang-Hyo;Park, Yong-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1737-1741
    • /
    • 2008
  • The electrochemical and thermal stability of $LiNi_{0.8}Co_{0.16}Al_{0.04}O_2$ were studied before and after $Co_3(PO_4)_2$ coating. Different to conventional coating material such as $ZrO_2$ or AlPO4, the coating layer was not detected clearly by TEM analysis, indicating that the $Co_3(PO_4)_2$ nanoparticles effectively reacted with surface impurities such as $Li_2CO_3$. The coated sample showed similar capacity at a low C rate condition. However, the rate capability was significantly improved by the coating effect. It is associated with a decrease of impedance after coating because impedance can act as a major barrier for overall cell performances in high C rate cycling. In the DSC profile of the charged sample, exothermic peaks were shifted to high temperatures and heat generation was reduced after coating, indicating the thermal reaction between electrode and electrolyte was sucessfully suppressed by $Co_3(PO_4)_2$ nanoparticle coating.