• 제목/요약/키워드: silver solution

검색결과 416건 처리시간 0.028초

자율신경계에 작용하는 약물이 위장 전기도에 미치는 영향 (Effect of Acetylcholine on Electrical Activity of Cat Stomach)

  • 김명석;박형진;배선호;최현;김철
    • The Korean Journal of Physiology
    • /
    • 제14권2호
    • /
    • pp.21-28
    • /
    • 1980
  • In order to investigate the effect of cholinergic substance on the electrical and the mechanical activities of the stomach muscle, 10 isolated cat stomachs were studied. At various sites of a stomach muscle preparation, the electrical activity was monopolarly recorded by using capillary electrodes containing chlorided silver wires, and the isometric contractile activity was recorded simultaneously at the terminal portion of the antrum in Krebs solution$(36^{\circ}C)$ which was aerated with a gas mixture consisting of 95% $O_2$ and 5% $CO_2$. The recording of these activities were performed before (control period) and after acetylcholine$(10^{-5}M)$ and atropine $(10^{-6}M)$ administrations serially. Following results were obtained: 1) The mean frequency of the slow wave was $4.36{\pm}0.22\;cycles/min$ at all the various sites of the cat stomach. The slow wave was propagated caudad in sequence and its velosity of propagation increased as the slow wave approached the pylorus in normal Krebs solution. 2) After acetylcholine administration, the frequency of the slow wave increased transiently and the increase of slow wave frequency was followed by the isometric contraction of antral muscle in association with the second potential which succeeded the slow wave. 3) By atropine administration, the stimulatory effect of acetylcholine on the antral muscle contraction was abolished completely, and the frequency of the slow wave decreased significantly compared with that of the control period, which tendency was more prominent in the antrum. The above results suggest that the transient increase in the frequency of gastric slow wave by acetylcholine may have some influence upon the contraction mechanism of the cat antral muscle.

  • PDF

제 2 급 와동에 충전된 Compome의 미세누출에 관한 연구 (MICROLEAKAGE OF COMPOMER IN CLASS II CAVITY)

  • 임재훈;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.346-355
    • /
    • 1999
  • To evaluate the micro leakage of compomer, 4 materials were divided into 4 groups of 15 cavities each.(Group 1: Z-100, Group 2: Dyarct AP, Group 3: Fuji II LC, Group 4: Compoglass) After the class II cavities were prepared using carbide bur No. 553, all specimen were restored by incremental filling technique. In group 3, Z-100 was filled with a base of a light curing glass-ionomer. After 7 days, all specimens were thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 500 cycles, followed by placement in 50% silver nitrate dye for 2 hours at $37^{\circ}C$. After rinsed in distilled water, these teeth were immersed in photodeveloping solution and exposed to fluorescent light for 6 hours. Teeth were then washed in distilled water to remove the photodeveloping solution, sectioned mesio-distally and evaluated. The results were as follows : 1. In the cervical portion, there was significant difference between Fuji II LC and other groups(Z-100, Dyract AP, Compoglass), Fuji II LC had the least value.(p<0.05) 2. In the cervical portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. 3. In the occlusal portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. From the results above, In enamel, microleakage of compomer such as Dyract AP and Compoglass resemble to that of composite resin. It is thought that it is due to characteristics of composite resin portion of compomer. But in dentin, microleakage of compomer is higher than that of resin modified glass ionomer cement, it is thought that in compomer, acid-base reaction is not developed with dentin.

  • PDF

신축성 금속 나노선 압저항 전극 기반 로젯 스트레인 센서 (Rosette Strain Sensors Based on Stretchable Metal Nanowire Piezoresistive Electrodes)

  • 김강현;차재경;김종만
    • 대한금속재료학회지
    • /
    • 제56권11호
    • /
    • pp.835-843
    • /
    • 2018
  • In this work, we report a delta rosette strain sensor based on highly stretchable silver nanowire (AgNW) percolation piezoresistors. The proposed rosette strain sensors were easily prepared by a facile two-step fabrication route. First, three identical AgNW piezoresistive electrodes were patterned in a simple and precise manner on a donor film using a solution-processed drop-coating of the AgNWs in conjunction with a tape-type shadow mask. The patterned AgNW electrodes were then entirely transferred to an elastomeric substrate while embedding them in the polymer matrix. The fabricated stretchable AgNW piezoresistors could be operated at up to 20% strain without electrical or mechanical failure, showing a maximum gauge factor as high as 5.3, low hysteresis, and high linearity ($r^2{\approx}0.996$). Moreover, the sensor responses were also found to be highly stable and reversible even under repeated strain loading/unloading for up to 1000 cycles at a maximum tensile strain of 20%, mainly due to the mechanical stability of the AgNW/elastomer composites. In addition, both the magnitude and direction of the principal strain could be precisely characterized by configuring three identical AgNW piezoresistors in a delta rosette form, representing the potential for employing the devices as a multidimensional strain sensor in various practical applications.

은나노입자의 방사성 동위원소 운반체 적용 유효성 검증 연구 (Feasibility Study on Silver Nanoparticle Application to a Radioisotope Carrier)

  • 장범수;이주상;박해준;김화정;박상현
    • 방사선산업학회지
    • /
    • 제5권3호
    • /
    • pp.197-202
    • /
    • 2011
  • In this study, an Ag-polyaniline-silica (Ag-PANI-silica) nanoparticle was evaluated as a radioisotope carrier. An Ag-PANI-silica nanoparticle was incubated in the $^{125}I$ solution for a duration of 24 hr to test its radioisotope absorptivity. During the incubation, radioactivity of the nanoparticle was measured at 3, 6, 12, and 24 hr. After a 24 hr incubation, $^{125}I$-Ag-PANI-silica nanoparticle was incubated in a fresh saline for a duration of 48 hr to check its stability. Additionally, the $^{125}I$-Ag-PANI-silica nanoparticle was injected to the ICR mouse to investigate its in-vivo distribution characteristics. The $^{125}I$ absorption yield of the Ag-PANI-silica nanoparticle was higher than 95% after a 6 hr incubation period in the $^{125}I$ solution. And $^{125}I$-Ag-PANI-silica was stable for 48 hr at 80% yield at room temperature. The SPECT/CT image of a mouse that received $^{125}I$-Ag-PANI-silica complex showed that the $^{125}I$-Ag-PANI-silica complex was distributed in the lung, stomach and thyroid at 30 min post injection. From these results, the Ag-PANI-silica nanoparticle has good radio-iodine carrying property and can be applicable for the purpose of diagnosis and therapy.

결정질 실리콘 태양전지의 고효율 화를 위한 Selective emitter 구조 및 Ni/Cu plating 전극 구조 적용에 관한 연구 (PA study on selective emitter structure and Ni/Cu plating metallization for high efficiency crystalline silicon solar cells)

  • 김민정;이재두;이수홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.91.2-91.2
    • /
    • 2010
  • The use of plated front contact for metallization of silicon solar cell may alternative technologies as a screen printed and silver paste contact. This technologies should allow the formation of contact with low contact resistivity a high line conductivity and also reduction of shading losses. The better performance of Ni/Cu contacts is attributed to the reduced series resistance due to better contact conductivity of Ni with Si and subsequent electroplating of Cu on Ni. The ability to pattern narrower grid lines for reduced light shading combined with the lower resistance of a metal silicide contact and improved conductivity of plated deposit. This improves the FF as the series resistance is deduced. This is very much required in the case of low concentrator solar cells in which the series resistance is one of the important and dominant parameter that affect the cell performance. A selective emitter structure with highly dopes regions underneath the metal contacts, is widely known to be one of the most promising high-efficiency solution in solar cell processing. This paper using selective emitter structure technique, fabricated Ni/Cu plating metallization cell with a cell efficiency of 17.19%.

  • PDF

Constant speed, variable ascension rate, helical trajectories for airplanes

  • Labonte, Gilles
    • Advances in aircraft and spacecraft science
    • /
    • 제5권1호
    • /
    • pp.73-105
    • /
    • 2018
  • A particular type of constant speed helical trajectory, with variable ascension rate, is proposed. Such trajectories are candidates of choice as motion primitives in automatic airplane trajectory planning; they can also be used by airplanes taking off or landing in limited space. The equations of motion for airplanes flying on such trajectories are exactly solvable. Their solution is presented, together with an analysis of the restrictions imposed on the geometrical parameters of the helical paths by the dynamical abilities of an airplane. The physical quantities taken into account are the airplane load factor, its lift coefficient, and the thrust its engines can produce. Formulas are provided for determining all the parameters of trajectories that would be flyable by a particular airplane, the final altitude reached, and the duration of the trajectory. It is shown how to construct speed interval tables, which would appreciably reduce the calculations to be done on board the airplane. Trajectories are characterized by their angle of inclination, their radius, and the rate of change of their inclination. Sample calculations are shown for the Cessna 182, a Silver Fox like unmanned aerial vehicle, and the F-16 Fighting Falcon.

마이크로 링이 함유된 비혼합성 에멀젼 액적의 분류를 위한 Pinched Flow Fractionation 마이크로 채널 (Pinched Flow Fractionation Microchannel to Sort Microring-Containing Immiscible Emulsion Droplets)

  • 예우준;김형건;변도영
    • 한국가시화정보학회지
    • /
    • 제15권2호
    • /
    • pp.41-47
    • /
    • 2017
  • Microring/nanoring structure has high applicability for nano-antenna and biosensor thanks to its superior optical characteristics. Although coiling nanowires manufactured using immiscible emulsion droplets have an advantage in mass production, this process also forms nanowire bundles. In this study, we solved the nanowire bundle problem by size-selective sorting of the emulsion droplets in a pinched flow fractionation microchannel. Utilizing silver nanowires and immiscible emsulsion droplets, we investigated the correlation between the size of ring droplets and bundle droplet. We visualized the sorting process for glass particles and microring-containing emulsion droplets. Droplets were sorted based on their size, and the ratio of bundle droplets in solution decreased. This droplet-sorting strategy has potential to help the printing and coating process for manufacturing of ring structure patterns and developing of functional materials.

Ionic Recognition with Quinone-Derivatized Calixarenes in Solution and at Self-Assembled Monlayers

  • Kim Hasuck;Kang Sun Kil;Chung Taek Dong
    • 전기화학회지
    • /
    • 제3권2호
    • /
    • pp.69-71
    • /
    • 2000
  • 카르복시산과 이황하물 다리를 가지며 산화환원 활성이 있는 칼릭스[4]아렌을 합성하였고 그것이 은과 금 표면 위에 자발적으로 흡착하는 것을 관찰하였다. 칼릭스[4]아렌은 특이한 구조 때문에 수용액에서 알칼리 토금속이온에 선택적인 친화력을 보인다 한편 둥그런 이온 수용체를 전극 위에 고정시켰을 때 금속 이온을 포획하는 것을 전압전류법 및 분광학적인 연구를 통해 확인하였다. 아울러 EDTA와 같은 강한 킬레이트제를 이용하여 이온을 가역적으로 제거할 수 있음을 보였다.

금왕 금·은광산 주변 지구화학적 환경에서의 중금속 원소들의 분산 (Dispersion of Heavy Metals in the Geochemical Environment around the Geumwang Gold-Silver Mine)

  • 박종진;김명균;전효택
    • 자원환경지질
    • /
    • 제30권5호
    • /
    • pp.407-416
    • /
    • 1997
  • Soil, tailings, stream sediment and surface water samples collected in the vicinity of the Geumwang Au-Ag mine were analyzed in order to investigate the pollution level of heavy metals and to determine the dispersion patterns. Although the maximum concentrations of soils collected at the flotation plant and tailings dam were 9,270 ppm As, 17 ppm Cd, 1,480 ppm Cu, 10,080 ppm Pb and 18,400 ppm Zn, dispersion of heavy metals were limited in the vicinity of the flotation plant and tailings dam. This may be due to high pH values (> 8.0) of the soils by flotation solution for mineral processing. The pH values of water samples near the flotation plant and tailings dam were over 8.0 and Cd, Cu and Zn concentrations were not detected. The waters in the vicinity of Geumwang mine generally belong to a $Ca^{2+}-SO_{4}{^{2-}}$ $(HCO_3{^-})$ type.

  • PDF

수용액에서 브롬산 이온을 제거하는 방법 (Removal of BrO3- from aqueous solution)

  • 임헌성;김종혁;이석근
    • 분석과학
    • /
    • 제24권5호
    • /
    • pp.401-405
    • /
    • 2011
  • 본 연구는 수용액 중의 발암물질로 규제되고 있는 브롬산 이온($BrO_3^-$)을 제거하는 방법에 관한 것이다. 브롬산 이온은 먹는 물의 정수 과정 중 브롬 이온의 존재 하에 오존 처리과정에서 생성되는 물질이다. 본 방법은 별다른 물리적 화학적 변화의 과정이 필요하지 않고, 활성알루미나를 이용하여 효과적으로 제거할 수 있어 먹는 물 등의 정수에도 유용하게 적용될 수 있다. 브롬산 이온 500 ${\mu}g$/L 농도의 용액을 표면 개질된 산성 활성알루미나를 사용하여 1~2 분 내에 95% 이상 제거하는 효과를 나타내었다.