• Title/Summary/Keyword: signals

Search Result 13,327, Processing Time 0.037 seconds

Development of a Digital Down-mixer to Convert 5.1 Channel Audio Signals to Stereo Signals (5.1 채널 오디오 신호를 스테레오 신호로 변환하는 디지털 다운믹서 개발)

  • Jeon, Kwang-Sub;Cheong, Ho-Yong;Lee, Seung-Yo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1764-1770
    • /
    • 2013
  • Use of the 5.1 channel audio signals suitable for the television system is improper for the radio broadcasting system, which uses the stereo audio system. Therefore, it is necessary to develop an audio down-mixer to convert 5.1 multi-channel audio signals to stereo signals for radio broadcasting. In this paper, a development of an audio down-mixer was carried out to convert 5.1 multi-channel audio signals to stereo signals. The down-mixer which was developed can use the audio signals separated from video signals, including sound signals or individual signals provided from 3-channel AES/EBU signals including Left(L), Right(R), Left Surround(Ls), Right Surround(Rs), Center(C) and Low Frequency Effect(Lfe) sounds as mixer inputs.

Bearing Fault Diagnostics in a Gearbox (기어박스에서의 베어링 결함 진단)

  • Kim, Heung-Sup;Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.611-616
    • /
    • 2002
  • Bearing diagnostics is difficult in a gearbox because bearing signals are masked by the strong gear signals. Self adaptive noise cancellation(SANC) is useful technique to seperate bearing signals from gear signals. While gear signals are correlated with a long correlation length, bearing signals are not correlated with a short length. SANC seperates two components on the basis of correlation length. Then we can find defect frequency component in the envelope spectrum of the bearing signals.

  • PDF

Implementation of a Modified SQI for the Preprocessing of Magnetic Flux Leakage Signal

  • Oh, Bok-Jin;Choi, Doo-Hyun
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.357-360
    • /
    • 2013
  • A modified SQI method using magnetic leakage flux (MFL) signal for underground gas pipelines' defect detection and characterization is presented in this paper. Raw signals gathered using MFL signals include many unexpected noises and high frequency signals, uneven background signals, signals caused by real defects, etc. The MFL signals of defect free pipelines primarily consist of two kinds of signals, uneven low frequency signals and uncertain high frequency noises. Leakage flux signals caused by defects are added to the case of pipelines having defects. Even though the SQI (Self Quotient Image) is a useful tool to gradually remove the varying backgrounds as well as to characterize the defects, it uses the division and floating point operations. A modified SQI having low computational complexity without time-consuming division operations is presented in this paper. By using defects carved in real pipelines in the pipeline simulation facility (PSF) and real MFL data, the performance of the proposed method is compared with that of the original SQI.

Segaration of Corrupted Speech Signals using Canonical Correlation Analysis (정준 상관 분석을 이용한 잡음 섞인 음성 신호의 분리)

  • Kim, Seon-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.164-167
    • /
    • 2012
  • The technology which is used for segregating voices signals from exhaust noise signals of a car is very practical one to realize the interfaces between men and machines using voices. The voice signals contaminated by exhaust noise signal of a car was separated by canonical correlation ananysis(CCA) in an environment which does not guarantee the independence between signals and have prior informations. Rearrangement for the input signals is important in CCA. CCA was studied and segragation between source signals were performed by CCA through rearrangements of each of signals. It is possible to apply the technique to various signals since it is also possible to use CCA to the signals which are not independent.

  • PDF

The Effect of LII Interference on the Measurement of PAH's LIF Signals using Ar-Ion Laser (아르곤이온 레이저를 이용한 확산화염 내 PAH의 LIF 신호 측정에 LII 신호가 미치는 영향)

  • Ahn, Taekook;Bae, Seungman;Lee, Wonnam;Park, Sunho
    • Journal of the Korean Society of Combustion
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • The effect of LII interference on the measurement of LIF signals from PAH in a diffusion flame has been investigated. Argon-ion laser at 488 nm was vertically or horizontally polarized, and irradiated to the centerline of the flame at varying flame height. Signals from PAH-rich regions measured at 515 nm were mostly LIF signals, however, signals from soot-rich regions were determined to be mixed with Mie scattering signals and/or LII signals. Signals measured 1 mm above the excitation height were mostly LII signals from soot particles. The results show that a quantitative determination of the LIF's contribution to the measured signals would be difficult as long as the experimental setup described here is used for the regions where PAHs and soot particles exist together.

Analysis of Acoustic Signals of Tendon Fractures (텐던 파단 음파의 분석)

  • Youn Seok Goo;Kim Eun Keum;Choi Min Seok;Kim yun Kyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.243-246
    • /
    • 2005
  • Using long-tenn monitoring AE techniques, two acoustic signals of wire fractures in a PSC beam are obtained. These data are compared to other noise signals. Based on the test results, the characteristics of the AE signals are classified and wire fracture signals are figured out among the other AE signals.

  • PDF

Bearing Falut Diagnostics in a Gearbox (기어 박스에서의 베어링 결함 진단)

  • Kim, Heung-Sup;Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.362.2-362
    • /
    • 2002
  • Bearing diagnostics is difficult in a gearbox because bearing signals are masked by the strong gear signals. Self adaptive noise cancellation(SANC) Is useful technique to seperate bearing signals from gear signals. While gear signals are correlated with a long correlation length, bearing signals are not correlated with a short length. SANC seperates two components on the basis of correlation length. (omitted)

  • PDF

Fault Diagnosis in Gear Using Adaptive Signal Processing (능동 신호 처리 이용한 기어의 이상 진단)

  • Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1114-1118
    • /
    • 2000
  • Impulsive sound and vibration signals in gear are often associated with their faults. Thus these impulsive sound and vibration signals can be used as indicators in the diagnosis of gear fault. The early detection of impulsive signal due to gear fault prevents from complete failure in gear. However it is often difficult to make objective measurement of impulsive signals because of background noise signals. In order to ease the detection of impulsive signals embedded in background noise, we enhance the impulsive signals using adaptive signal processing.

  • PDF

Demodulation and Performance of Multicomponent Undersampled AM, FM and AM-FM Signals (다중 성분의 저표본화된 AM, FM 및 AM-FM 신호들의 복조와 성능)

  • Son, Tae-Ho;Hwang, Ui-Cheon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.7
    • /
    • pp.399-406
    • /
    • 2000
  • We propose an nonlinear demodulation algorithm for undersampled multicomponent AM(Amplitude Modulation), FM(Frequency Modulation) and AM-FM signals. First, we derive respectively undersampling frequency of the AM, FM and AM-FM using undersampling scheme, and separate respectively monocomponent signals from multicomponent signals using periodic algebraic separation algorithm. In this case augmented separation matrix is very regular and sparse, it has a special structure. The proposed demodulation algorithm detects respectively message signals of the IA(Instantaneous Amplitude) and IF(Instantaneous Frequency) from descrete monocomponent AM, FM and AM-FM signals with an undersampling frequency to be controllable. Verifying the RMS(Root Mean Squares) errors of the detected signals, we show that the performance is excellent.

  • PDF

A Study on Partial Discharge Measurement using Optical Fiber Sensors (광섬유 센서를 이용한 부분방전 측정연구)

  • Lee, June-Ho;Lee, Cheol-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF