• Title/Summary/Keyword: signal power.

Search Result 5,945, Processing Time 0.043 seconds

A Spoofing Detection Scheme Based on Elevation Masked-Relative Received Power in GPS Receivers using Multi-band Array Antenna

  • Junwoo Jung;Hyunhee Won;Sungyeol Park;Haengik Kang;Seungbok Kwon;Byeongjin Yu;Seungwoo Seo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.101-111
    • /
    • 2023
  • Many spoofing detection studies have been conducted to cope with the most difficult types of deception among various disturbances of GPS, such as jamming, spoofing, and meaconing. In this paper, we propose a spoofing detection scheme based on elevation masked-relative received power between GPS L1 and L2 signals in a system using a multi-band array antenna. The proposed scheme focuses on enabling spoofing to be normally detected and minimizes the possibility of false detection in an environment where false alarms may occur due to pattern distortion among elements of an array antenna. The pattern distortion weakens the GPS signal strength at low elevation. It becomes confusing to detect a spoofing signal based on the relative power difference between GPS L1 and L2, especially when GPS L2 has weak signal strength. We propose design parameters for the relative power threshold including beamforming gain, the minimum received power difference between L1 and L2, and the patch antenna gain difference between L1 and L2. In addition, in order to eliminate the weak signal strength of GPS L2 in the spoofing detection process, we propose a rotation matrix that sets the elevation mask based on platform coordinates. Array antennas generally do not have high usefulness in commercial areas where receivers are operated alone, but are considered essential in military areas where GPS receivers are used together with signal processing for beamforming in the direction of GPS satellites. Through laboratory and live sky tests using the device under test, the proposed scheme with an elevation mask detects spoofing signals well and reduces the probability of false detection relative to that without the elevation mask.

Design of Power Amplifier and Antenna for Power Transmission at RF-ID (RF-ID에서 전력전송을 위한 전력증폭기와 송수신 Antenna 설계)

  • Yim Sang-Wook;Kim Yong-Sang;Kim Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1263-1265
    • /
    • 2004
  • RF-ID system is one of the very interesting field not only in a technical and economical point of view but also that people are still trying to realize lossless power transmission. This paper has a purpose on the efficient power transmission at the passive type IDcard by using wireless power transmission system. The most difficult but important part of the passive type RF-ID system is building the system that supplies power from Reader-antenna to IDcard-antenna. To check what is the most efficient way to deliver power depending on what kind of specifications of the power-amp in reader, antenna and antenna in IDcard is for operating IDcard circuit efficiently receiving the power from reader-antenna. For this, we used 125kHz sinewave for RF signal as a basic specification, OP-amp for amplifying signal and power-amp for amplifying power, loop type antenna.

  • PDF

Design and Implementation of L/Ku-band Broadband Power Detector using Schottky Diode (Schottky 다이오드를 이용한 Six-port용 L/Ku-band 광대역 Power detector 설계 제작)

  • Kim Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.615-618
    • /
    • 2006
  • The broadband power detector for direct- onversion Six-port output circuit was designed and implementaed in this paper. The power detector should linearly operated to produce the linear amplitude and phase signal fer input RF signal in required broadband. So, the power detector should be designed under conditions of matching circuit with low VSWR. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with matching circuit and isolator, respectively, were evaluated in the performances.

  • PDF

Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Park, Chung-Ha;Song, Yong-Jae;Kim, Jae-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

Digital Pre-distorter for Communication Transmitters (통신용 송신기의 디지털 Pre-distorter)

  • 한동석;김용정김대진김창주
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.211-214
    • /
    • 1998
  • The high power amplifier (HPA) for broadcasting transmitter systems has nonlinear property in terms of input signal power. Hence, it produces AM/AM and AM/PM modulation to the modulated signal. Therefore, the non-linearity results in bandwidth expansion and nonlinear distortion to in-band signal. In this paper, we propose a simple sain-based predistorter that requires less computational burden and less time for the full initialization of the pre-distorter ROM table.

  • PDF

Study on the Effect of Metal-Wall Loading on the DC Power-Bus

  • Kahng Sungtek
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.4
    • /
    • pp.193-196
    • /
    • 2005
  • The DC power-bus for the PCB is loaded with metal walls on its selected sides and is characterized electromagnetically. This is a novel concept of approach to mitigate the spurious resonance and finally signal integrity problems. In particular, the peak at DC, which is always in the way to secure parallel-plates' EMC, can be completely removed by the proposed method. Through the findings of this study, the effect of metal-loading of the power-bus will be presented along with the impression that the suggested technique can tackle the headaches of signal integrity, ground bounce, EMIs.

The Time Variant Power Signal Processing of Wind Generator using Buneman Frequency Estimator Algorithm (부너맨 주파수 추정 알고리듬을 이용한 풍력발전기 가변 전력신호 처리에 관한 연구)

  • Choi, Sang-Yule;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.138-146
    • /
    • 2010
  • On wind turbine generators, the speed and volume of the wind affect the turbine angle speed which finally determines the output level of the electric power. However it is very difficult to forecast correctly the future power output and quality based on previous fixed sampling methods. This paper proposes a variable sampling method based on Buneman frequency estimation algorithm to reflect the variations of the frequency and amplitude on wind power outputs. The proposed method is also verified through the performance test by comparing with the results from previous fixed sampling methods and the real measurement data.

Gain and spectra stabilization in erbium-doped fiber amplifier with optical feedback (광 귀환에 의한 erbium 첨가 광섬유 증폭기의 이득과 ASE 스펙트럼 안정화)

  • 김호삼;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.291-297
    • /
    • 1994
  • A feedback loop with bandpass filter is introduced in erbium-doped fiber amplifier to clamp the amplifier gain by lasing the amplifier at a selected wavelength. The gain and the ASE (amplified spontaneous emission) output spectra are found to be independent of input signal power and pump power variation so long as the amplifier is lasing. Also they are found to be dependent only on the overall loss of the feedback loop. Even in the case of slowly modulated large signal input, signal distortion due to gain saturation is not observed.served.

  • PDF

A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant (수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구)

  • Byun, Doo-Gyoon;Chang, Moon-Soung;Kim, Ju-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

Design of a Power Factor Measurement System for Nonlinear Load

  • Shahriar, Md. Rifat;Chong, Ui-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.113-122
    • /
    • 2011
  • This paper introduces and develops an efficient method for measuring power factor (PF) and its nature under nonlinear load current situations. The method is based on generating a pulse width modulated signal whose width correlates to the value of PF. This signal can then be employed as a feedback signal for controlling PF related power quantities in a system. This method has the advantages of its simple implementation, less computational complexity, and its allowable error of less than 4[%], which is justified by the computer simulation results.