• Title/Summary/Keyword: signal head

Search Result 414, Processing Time 0.024 seconds

Design of a Highly Integrated Palette-type High Power Amplifier Module Using GaN Devices for DPD Application (질화갈륨 소자를 이용한 DPD용 고집적 팔렛트형 고출력증폭기 모듈 설계)

  • Oh, Seong-Min;Lim, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2241-2248
    • /
    • 2011
  • This paper describes the design of a palette-type 60watt high power amplifier module using gallium nitride(GaN) devices with high power and efficiency performances for WiMAX and LTE systems. The line-up for the high gain amplifier module consists of the pre-amplifier stage with low power and high gain, 8watt GaN driving amplifier stage, and 60watt GaN high power amplifier stage of Doherty structure with two 30watt GaN devices. The obtained gain is 61.4dB with an excellent gain flatness of ${\pm}$0.075dB over 2.5~2.68GHz. GaN devices and the Doherty structure are adopted for the improvement of high efficiency and output power. The measurement for the fabricated high power amplifier module of palette type is performed using the widely known WiMAX signal all over the world. In the example of RRH(remote radio head) application of the fabricated amplifier module, the measured efficiency is 37~38% with the 10watts of modulated output power. It is shown that when the fabricated amplifier module is activated with a digital predistorter(DPD), the measured ACLR is better than 46dBc under the 10watts of modulated output power.

A Study on Apparatus of Smart Wearable for Mine Detection (스마트 웨어러블 지뢰탐지 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • current mine detector can't division the section if it is conducted and it needs too much labor force and time. in addition to, if the user don't move the head of sensor in regular speed or move it too fast, it is hard to detect a mine exactly. according to this, to improve the problem using one direction ultrasonic wave sensing signal, that is made up of human body antenna part, main micro processor unit part, smart glasses part, body equipped LCD monitor part, wireless data transmit part, belt type power supply part, black box type camera, Security Communication headset. the user can equip this at head, body, arm, waist and leg in removable type. so it is able to detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal and it can express the 2D or 3D film about distance, form and material of the mine. so the battle combats can avoid the mine and move fast. also, through the portable battery and twin self power supply system of the power supply part, combat troops can fight without extra recharge and we can monitoring the battle situation of distant place at the command center server on real-time. and then, it makes able to sharing the information of battle among battle combats one on one. as a result, the purpose of this study is researching a smart wearable mine detector which can establish a smart battle system as if the commander is in the site of the battle.

Study of Design of Traffic Lights for the Prevention of Disaster to be prepared for a Super-aged Society (초고령사회에 대비한 교통신호등 방재디자인 연구)

  • Lee, Hyun-Ju;Roh, Hwang-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.560-567
    • /
    • 2019
  • South Korea, which has entered an aged society, is about to enter a super-aged society in 2025. With the increase of an aging population, traffic accidents by aged drivers have been settled as a social problem. Now, when Korea is facing a super-aged society to come, a study was conducted to prevent traffic accidents that occur while the elderly people are driving through a disaster prevention design. For theoretical research, this study examined the concept and necessity of disaster prevention design, the present condition of an aged society, aged drivers' physical and cognitive characteristics, and the policies related to the forms of traffic lights the elderly people see. In addition, to propose the design, this study investigated and analyzed the traffic safety forms and colors of the International Standards Organization and proposed the first and second forms of the design of traffic lights for the gradual improvement of the traffic lights based on that. The first improved design form is a plan for displaying a triangle, an arrow with a large area, and a quadrangle in the lens of the head of the existing traffic lights, and the second improved design form is a plan for introducing a new traffic light head and forming the traffic light with a bigger triangle, an arrow with a large area and a quadrangular lens. Since it has a visually clearer form than the present traffic lights, it is expected that aged drivers who have physical and cognitive characteristics due to aging can secure better visibility and conspicuity and that they can make better reflex responses than they can now, also in the change of driving environment (rain and heavy snowstorm, etc.). In addition, it is expected that this study would be a preceding study to prepare standard guidelines on traffic safety signs other than traffic lights to be prepared for the super-aged society.

Analysis of Magnetic Flux Leakage based Local Damage Detection Sensitivity According to Thickness of Steel Plate (누설자속 기반 강판 두께별 국부 손상 진단 감도 분석)

  • Kim, Ju-Won;Yu, Byoungjoon;Park, Sehwan;Park, Seunghee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • To diagnosis the local damages of the steel plates, magnetic flux leakage (MFL) method that is known as a adaptable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied in this study. To analysis the sensitivity according to thickness of steel plate in MFL method based damage diagnosis, several steel plate specimens that have different thickness were prepared and three depths of artificial damage were formed to the each specimens. To measured the MFL signals, a MFL sensor head that have a constant magnetization intensity were fabricated using a hall sensor and a magnetization yoke using permanent magnets. The magnetic flux signals obtained by using MFL sensor head were improved through a series of signal processing methods. The capability of local damage detection was verified from the measured MFL signals from each damage points. And, the peak to peak values (P-P value) extracted from the detected MFL signals from each thickness specimen were compared each other to analysis the MFL based local damage detection sensitivity according to the thickness of steel plate.

Development of a Listener Position Adaptive Real-Time Sound Reproduction System (청취자 위치 적응 실시간 사운드 재생 시스템의 개발)

  • Lee, Ki-Seung;Lee, Seok-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.458-467
    • /
    • 2010
  • In this paper, a new audio reproduction system was developed in which the cross-talk signals would be reasonably cancelled at an arbitrary listener position. To adaptively remove the cross-talk signals according to the listener's position, a method of tracking the listener position was employed. This was achieved using the two microphones, where the listener direction was estimated using the time-delay between the two signals from the two microphones, respectively. Moreover, room reverberation effects were taken into consideration where linear prediction analysis was involved. To remove the cross-talk signals at the left-and right-ears, the paths between the sources and the ears were represented using the KEMAR head-related transfer functions (HRTFs) which were measured from the artificial dummy head. To evaluate the usefulness of the proposed listener tracking system, the performance of cross-talk cancellation was evaluated at the estimated listener positions. The performance was evaluated in terms of the channel separation ration (CSR), a -10 dB of CSR was experimentally achieved although the listener positions were more or less deviated. A real-time system was implemented using a floating-point digital signal processor (DSP). It was confirmed that the average errors of the listener direction was 5 degree and the subjects indicated that 80 % of the stimuli was perceived as the correct directions.

A Study on the Current Measurement Using birefringence Fiber (복굴절 광섬유를 이용한 전류측정에 관한 연구)

  • Jang Nam-Young;Choi Pyung-Suk;Eun Jae-Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.2
    • /
    • pp.59-66
    • /
    • 2005
  • Accuracy of current measurement in fiber optic current sensor(FOCS), especially, unidirectional polarimetric fiber optic current sensor(PFOCS) is affected by the environment perturbations such as acoustic vibrations changes to the sensing fiber, and intrinsic perturbations such as the bending fiber that the sensing fiber wound around a current carrying wire. The perturbations affect the birefringence properties of sensing fiber in sensor head and cause false current readings. Thus, using compensation technique, reciprocal PFOCS, for unidirectional PFOCS the perturbations are suppressed. In this paper, we carried out the numerical analysis of performance in reciprocal PFOCS including the degree of polarization error, and false current of environmental and intrinsic perturbations on the sensing fiber. Also, we compared the effect of mirror with the faraday rotation mirror(FRM) in reciprocal PFOCS configuration. And the different optical source's wavelengths, 633nm and 1300nm is used. In the results, at 633nm, using mirror and FRM, the degree of polarization error is calculated to $2.3\%$ and $0.0196\%$, respectively. At $1300{\cal}nm$ using mirror and FRM the degree of polarization error is calculated to $9.97\%$ and $0.0196\%$, respectively. Also, compared with false current, the results is calculated to $9.82{\times}10^{-9}A$ and $1.4{\times}10^{-17}A$, respectively, and show that the reciprocal PFOCS is more robust configuration than unidiretionnal PFOCS for environmental and intrinsic perturbations.

  • PDF

Depiction of Acute Stroke Using 3-Tesla Clinical Amide Proton Transfer Imaging: Saturation Time Optimization Using an in vivo Rat Stroke Model, and a Preliminary Study in Human

  • Park, Ji Eun;Kim, Ho Sung;Jung, Seung Chai;Keupp, Jochen;Jeong, Ha-Kyu;Kim, Sang Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. Materials and Methods: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a $B_{1,rms}$ amplitude of $1.2{\mu}T$ using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. Results: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at $1.2{\mu}T$ power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. Conclusion: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the $1.2{\mu}T$ power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.

The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams (고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 1995
  • Lithium Fluoride (LiF; TLD-100) crystal chips are normally used as thermolu minescence dosimeters (abbreviated as NC-100) for estimating the absorbed dose to the skin of a patient or in a solid water phantom undergoing radiotherapy with megavoltage photon (6 and 15MV) beams. In general, investigation has revealed a reduction in the sensitivity of NC-100 chips after many runs through heating cycles. A TLD-100 chip laminated with gold plate (140${\mu}{\textrm}{m}$) on the upper surface layer of its face toward the photon beam (abbreviated as GC-100) has properties different from that of a NC-100 chip activated by incident photons and contaminant electrons with various lower energies coming from the gantry head and air. Activation of the valence band electrons of GC-100 chips by incident photons, positrons and electrons-which come from the gold plate by mainly pair production process and partly from Compton scattering-results in more enhanced signal intensity, higher response per monitor unit, as well as a good linearity with monitor units and independence of dose rate. Since the electron beams (6 and 15 MeV) do not have the probability of pair production process with gold plate, there is only a small difference (about a 3.3% increase for 15 MeV) in the signal gaps in the TL readout for electron beams between GC- and NC-100 chips. The 3.3% increase is entirely due to the buildup caused by the 140 m gold plate. The sensitivity of GC-100 chips is much more susceptible to high energy photon beams than electron one because of pair production. The interaction of high energy photon with a material of high atomic number, such as the good plate in this case, results in a considerably significant probability of pair production. The gold plate on the NC-100 chips acts as not only an intensifier of their signals but also acts as a filter of contaminant electrons in therapeutic high energy X-ray beams.

  • PDF

Development of MRI Phantom for Assessing MR Image Quality (자기공명영상 화질 평가용 팬텀 개발에 관한 연구)

  • Ahn, Chang-Beom;Na, Dong-Gyu;Kim, Kwang-Gi;Kim, Dong-Sung;Kim, In-Su;Lee, Jung-Whee;Hong, Suk-Joo;Byun, Jae-Ho;Khang, Hyun-Soo;Jang, Gi-Won;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • Purpose : To evaluate MR image qualities we developed a new MRI phantom with the fixation structures necessary to position it into coil firmly. Materials and methods : We designed MRI phantom for eight evaluation items such as slice thickness accuracy, high contrast spatial resolution, low contrast object detectability, geometry accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting and signal to noise ratio. For the positioning of phantom at coils, the fixation structures were set up on the surface of phantom. Six different MRI units were used for test the possibility for the clinical application and their image qualities were evaluated. Results : We acquired appropriate MR image qualities enough for the evaluation on all used MR units and confirmed that their evaluations were within reliable values compared to real ones for some items. The positioning of our phantom into head coils with fixation structures worked well for proper imaging. Conclusion : We found that our prototype of MRI phantom had the possibility of clinical application for MR image quality assessment.

  • PDF

Literature review on maternal-fetal interaction (모-태아 상호작용에 대한 문헌고찰)

  • Cho, Kyeul-Ja;Kim, Jung-Soon
    • Korean Parent-Child Health Journal
    • /
    • v.3 no.2
    • /
    • pp.49-66
    • /
    • 2000
  • Pregnancy is a task of creation in which a women mobilizes her self and the resources available to her in the generation of a new person. Through the pregnancy, a mother has formed the new human relationship with a fetus. Maternal-fetal relationship is considered one of mechanism making the relationship of mother and child. It is important to well-being of mother and fetus, too. The earliest interaction between a mother and her child is during prenatal period. Maternal-fetal dyad is unique and perceived interactions with the fetus make the pregnancy real for the mother. Maternal behavior is "instinctive" and is formed in early childhood by copy of the mother. But, Rubin argues that this behavior is an open intellectual system rather than a prepackaged bundle of traits. There is openness to new learning and a high value placed on knowing which occurs with silent organization in thought. Thus, nurses and other health professionals provide prenatal care that optimally is part of the environment in which the maternal-fetal dyad develops. Thus it is appropriate for nurses to increases their understanding of the dyad and to explore ways to enhance its development. This study focusses on the interaction ability and response of fetus, and the maternal-fetal interaction. The research of fetal responses that involve physiological changes and motor movement have been shown to coccur to both external sensory stimuli and to maternal emotional states. The fetus does also have sensory capacity to be aware of some maternal behaviors, and the motor ability to respond in a way the mother can notice. Thus, very rudimentary interactions appear to be possible. Maternal awareness of fetal activity was supported by several studies. More interesting to the present study are description of maternal-fetal interaction and the finding that there appear to be levels of sensitivity to the fetus involved in maternal-fetal interactions. First, recognition comes that the fetus is separate from the maternal self. Next, the fetus engages in. Lastly, the parent may describe active interaction with the fetus, believing that mother and fetus are communicating on a meaningful level. Several interventions, developed to promote more active interaction between mother and fetus, have been reviewed. In general, the parents were taught to stimulate the fetus and to notice the fetus' responses. This type of intervention might increase the mother's sensitivity to her unborn baby, and she may have a head start toward learning how to res pond sensitivity to the newborn infant. Research In the area of maternal-fetal interaction is scarce. Sensitive behavior is construed as an appropriate and timely response to a signal of need from another person, but no such signal of need can be claimed regarding the fetus. The highest level of maternal-fetal interaction, therefore, might be based more on maternal representations of the imagined fetus than on factual evidence of fetal participation.

  • PDF