• Title/Summary/Keyword: signal coverage

Search Result 217, Processing Time 0.018 seconds

Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation (정전용량변화를 이용한 링거액소진감지장치의 구현)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.

Multi-Objective Handover in LTE Macro/Femto-Cell Networks

  • Roy, Abhishek;Shin, Jitae;Saxena, Navrati
    • Journal of Communications and Networks
    • /
    • v.14 no.5
    • /
    • pp.578-587
    • /
    • 2012
  • One of the key elements in the emerging, packet-based long term evolution (LTE) cellular systems is the deployment of multiple femtocells for the improvement of coverage and data rate. However, arbitrary overlaps in the coverage of these femtocells make the handover operation more complex and challenging. As the existing handover strategy of LTE systems considers only carrier to interference plus noise ratio (CINR), it often suffers from resource constraints in the target femtocell, thereby leading to handover failure. In this paper, we propose a new efficient, multi-objective handover solution for LTE cellular systems. The proposed solution considers multiple parameters like signal strength and available bandwidth in the selection of the optimal target cell. This results in a significant increase in the handover success rate, thereby reducing the blocking of handover and new sessions. The overall handover process is modeled and analyzed by a three-dimensional Markov chain. The analytical results for the major performance metrics closely resemble the simulation results. The simulation results show that the proposed multi-objective handover offers considerable improvement in the session blocking rates, session queuing delay, handover latency, and goodput during handover.

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.

Development of a DTV RF Capture and Regeneration System (DTV RF 신호 저장 및 재생 시스템의 개발)

  • 서영우;목하균;권태훈;임재원
    • Journal of Broadcast Engineering
    • /
    • v.8 no.2
    • /
    • pp.126-135
    • /
    • 2003
  • To investigate the DTV coverage especially in downtown areas and improve the performance of DTV receivers, it is necessary to capture the receiving DTV signals that contain the complex characteristics of the real-world RF environments and regenerate them in a laboratory without the performance degradation. In this paper, we developed a DTV RF capture and regeneration system adapting digital signal processing and high speed hard disk storage techniques and analyze its characteristics. The system can capture and replay the DTV RF signals based on a real-time condition in a hard disk. There Is no time limit for capturing RF data within the installed storage capacity. We can expect various Possible applications for this system such as a tool for the development of the receiver performance analysis, design and analysis for the DTV coverage areas, etc.

Interference Aware Fractional Frequency Reuse using Dynamic User Classification in Ultra-Dense HetNets

  • Ban, Ilhak;Kim, Se-Jin
    • Journal of Internet Computing and Services
    • /
    • v.22 no.5
    • /
    • pp.1-8
    • /
    • 2021
  • Small-cells in heterogeneous networks are one of the important technologies to increase the coverage and capacity in 5G cellular networks. However, due to the randomly arranged small-cells, co-tier and cross-tier interference increase, deteriorating the system performance of the network. In order to manage the interference, some channel management methods use fractional frequency reuse(FFR) that divides the cell coverage into the inner region(IR) and outer region(OR) based on the distance from the macro base station(MBS). However, since it is impossible to properly measure the distance in the method with FFR, we propose a new interference aware FFR(IA-FFR) method to enhance the system performance. That is, the proposed IA-FFR method divides the MUEs and SBSs into the IR and OR groups based on the signal to interference plus noise ratio(SINR) of macro user equipments(MUEs) and received signals strength of small-cell base stations(SBSs) from the MBS, respectively, and then dynamically assigns subchannels to MUEs and small-cell user equipments. As a result, the proposed IA-FFR method outperforms other methods in terms of the system capacity and outage probability.

On Deploying Relays for Connected Indoor Sensor Networks

  • Zhu, Yanmin;Xue, Cuiyao;Cai, Haibin;Yu, Jiadi;Ni, Lei;Li, Minglu;Li, Bo
    • Journal of Communications and Networks
    • /
    • v.16 no.3
    • /
    • pp.335-343
    • /
    • 2014
  • This paper considers the crucial problem of deploying wireless relays for achieving a connected wireless sensor network in indoor environments, an important aspect related to the management of the sensor network. Several algorithms have been proposed for ensuring full sensing coverage and network connectivity. These algorithms are not applicable to indoor environments because of the complexity of indoor environments, in which a radio signal can be dramatically degraded by obstacles such as walls. We first prove theoretically that the indoor relay placement problem is NP-hard. We then predict the radio coverage of a given relay deployment in indoor environments. We consider two practical scenarios; wire-connected relays and radio-connected relays. For the network with wire-connected relays, we propose an efficient greedy algorithm to compute the deployment locations of relays for achieving the required coverage percentage. This algorithm is proved to provide a $H_n$ factor approximation to the theoretical optimum, where $H_n=1+{\frac{1}{2}}+{\cdots}+{\frac{1}{n}}={\ln}(n)+1$, and n is the number of all grid points. In the network with radio-connected relays, relays have to be connected in an ad hoc mode. We then propose an algorithm based on the previous algorithm for ensuring the connectivity of relays. Experimental results demonstrate that the proposed algorithms achieve better performance than baseline algorithms.

Integrative Modeling of Wireless RF Links for Train-to-Wayside Communication in Railway Tunnel

  • Pu, Shi;Hao, Jian-Hong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.2
    • /
    • pp.19-27
    • /
    • 2012
  • In railway tunnel environment, the reliability of a high-data-rate and real-time train-to-wayside communication should be maintained especially when high-speed train moves along the track. In China and Europe, the communication frequency around 900 MHz is widely used for railway applications. At this carrier frequency band, both of the solutions based on continuously laid leaky coaxial cable (LCX) and discretely installed base-station antennas (BSAs), are applied in tunnel radio coverage. Many available works have concentrated on the radio-wave propagation in tunnels by different kinds of prediction models. Most of them solve this problem as natural propagation in a relatively large hollow waveguide, by neglecting the transmitting/receiving (Tx/Rx) components. However, within such confined areas like railway tunnels especially loaded with train, the complex communication environment becomes an important factor that would affect the quality of the signal transmission. This paper will apply a full-wave numerical method to this case, for considering the BSA or LCX, train antennas and their interacted environments, such as the locomotive body, overhead line for power supply, locomotive pantograph, steel rails, ballastless track, tunnel walls, etc.. Involving finite-difference time-domain (FDTD) method and uni-axial anisotropic perfectly matched layer (UPML) technique, the entire wireless RF downlinks of BSA and LCX to tunnel space to train antenna are precisely modeled (so-called integrative modeling technique, IMT). When exciting the BSA and LCX separately, the field distributions of some cross-sections in a rectangular tunnel are presented. It can be found that the influence of the locomotive body and other tunnel environments is very significant. The field coverage on the locomotive roof plane where the train antennas mounted, seems more homogenous when the side-laying position of the BSA or LCX is much higher. Also, much smoother field coverage solution is achieved by choosing LCX for its characteristic of more homogenous electromagnetic wave radiation.

A Joint SD-MRC Method for Downlink Performance Improvement at Coverage Boundaries of Cellular Systems (셀룰러 시스템의 셀 경계에서의 하향 링크 성능 향상을 위한 Joint SD-MRC 수신 방식)

  • Lee, Sang-Dae;Chang, Jae-Won;Sung, Won-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.506-514
    • /
    • 2008
  • At coverage boundaries of cellular systems including the recent WiBro standard which operate with full frequency reuse for increased spectral efficiency, interference signals from the base stations(BS) of adjacent cells degrade the receiver performance. In this paper, a detection method for multiple-antenna mobile stations(MS) is proposed for downlink performance improvement at coverage boundaries of cellular systems. For the performance verification, we obtain the probability density function(pdf) of the effective signal-to-interference and noise ratio(SINR) according to the variation of the interference signals from adjacent cells as well as the number of MS antennas, and calculate the transmission efficiency. We also verify the performance of proposed method with simulation results, to demonstrate a significant performance improvement is achieved over the maximal ratio combining(MRC) and spatial demultiplexing(SD) methods in terms of the effective SINR and the spectral efficiency.

Measurement and Comparison of Wi-Fi and Super Wi-Fi Indoor Propagation Characteristics in a Multi-Floored Building

  • Hwang, Gyumin;Shin, Kyubo;Park, Sanghyeok;Kim, Hyoil
    • Journal of Communications and Networks
    • /
    • v.18 no.3
    • /
    • pp.476-483
    • /
    • 2016
  • Super Wi-Fi is a Wi-Fi-like service exploiting TV white space (WS) which is expected to achieve larger coverage than today's Wi-Fi thanks to its superior propagation characteristics. Super Wi-Fi has been materialized as an international standard, IEEE 802.11af, targeting indoor and outdoor applications, and is undergoing worldwide field tests. This paper demonstrates the true potential of indoor Super Wi-Fi, by experimentally comparing the signal propagation characteristics of Super Wi-Fi and Wi-Fi in the same indoor environment. Specifically, we measured the wall and floor attenuation factors and the path-loss distribution at 770MHz, 2.401 GHz, and 5.540 GHz, and predicted the downlink capacity of Wi-Fi and Super Wi-Fi. The experimental results have revealed that TVWS signals can penetrate up to two floors above and below, whereas Wi-Fi signals experience significant path loss even through a single floor. It has been also shown that Super Wi-Fi mitigates shaded regions of Wi-Fi by providing almost-homogeneous data rates within its coverage, performs comparable to Wi-Fi utilizing less bandwidth, and always achieves better spectral efficiency than Wi-Fi. The observed phenomena imply that Super Wi-Fi is suitable for indoor applications and has the potential of extending horizontal and vertical coverage of today's Wi-Fi.

Channel Capacity of Mobile Communication System using Switching Repeater (스위칭 중계기를 사용한 이동통신 시스템의 채널용량)

  • Kim, jang-Wook;Choi, Wan;Oh, Chang-Heon;Cho, Sung-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.33-39
    • /
    • 2002
  • In mobile communication systems, there are areas where signal coverage is not adequately accomplished by base stations. These areas may be underground parking zones, underground stores, tunnels, and insides of buildings, etc. In these areas, repeaters are broadly used as an economical solution. However, the capacity is decreased as the number of repeaters increases because the noise power that flows to a base station in the reverse link is proportional to the number of repeaters. The reduction of capacity in the reverse link is no longer negligible in the case that several tens or hundreds repeaters are connected to a base station. In this paper, we propose c repeater that is switched off automatically when there is no active user within its coverage. With the switching repeater, we can reduce the unnecessary noise level enhancement when there is no active user within the repeaters coverage. The reverse link capacity of a DS/CDMA system with AOS repeater is analyzed mathematically and compared with that without switching repeater. From the numerical results, noticeable improvement with the switching repeaters is shown.