• Title/Summary/Keyword: signal control scheme

Search Result 624, Processing Time 0.027 seconds

Improvement of LMS Algorithm Convergence Speed with Updating Adaptive Weight in Data-Recycling Scheme (데이터-재순환 구조에서 적응 가중치 갱신을 통한 LMS 알고리즘 수렴 속 도 개선)

  • Kim, Gwang-Jun;Jang, Hyok;Suk, Kyung-Hyu;Na, Sang-Dong
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.9 no.4
    • /
    • pp.11-22
    • /
    • 1999
  • Least-mean-square(LMS) adaptive filters have proven to be extremely useful in a number of signal processing tasks. However LMS adaptive filter suffer from a slow rate of convergence for a given steady-state mean square error as compared to the behavior of recursive least squares adaptive filter. In this paper an efficient signal interference control technique is introduced to improve the convergence speed of LMS algorithm with tap weighted vectors updating which were controled by reusing data which was abandoned data in the Adaptive transversal filter in the scheme with data recycling buffers. The computer simulation show that the character of convergence and the value of MSE of proposed algorithm are faster and lower than the existing LMS according to increasing the step-size parameter $\mu$ in the experimentally computed. learning curve. Also we find that convergence speed of proposed algorithm is increased by (B+1) time proportional to B which B is the number of recycled data buffer without complexity of computation. Adaptive transversal filter with proposed data recycling buffer algorithm could efficiently reject ISI of channel and increase speed of convergence in avoidance burden of computational complexity in reality when it was experimented having the same condition of LMS algorithm.

Preprocessing method for enhancing digital audio quality in speech communication system (음성통신망에서 디지털 오디오 신호 음질개선을 위한 전처리방법)

  • Song Geun-Bae;Ahn Chul-Yong;Kim Jae-Bum;Park Ho-Chong;Kim Austin
    • Journal of Broadcast Engineering
    • /
    • v.11 no.2 s.31
    • /
    • pp.200-206
    • /
    • 2006
  • This paper presents a preprocessing method to modify the input audio signals of a speech coder to obtain the finally enhanced signals at the decoder. For the purpose, we introduce the noise suppression (NS) scheme and the adaptive gain control (AGC) where an audio input and its coding error are considered as a noisy signal and a noise, respectively. The coding error is suppressed from the input and then the suppressed input is level aligned to the original input by the following AGC operation. Consequently, this preprocessing method makes the spectral energy of the music input redistributed all over the spectral domain so that the preprocessed music can be coded more effectively by the following coder. As an artifact, this procedure needs an additional encoding pass to calculate the coding error. However, it provides a generalized formulation applicable to a lot of existing speech coders. By preference listening tests, it was indicated that the proposed approach produces significant enhancements in the perceived music qualities.

Optimization of Fixed-point Design on the Digital Front End in IEEE 802.16e OFDMA-TDD System (IEEE 802.16e OFDMA-TDD 시스템 Digital Front End의 Fixed-point 설계 최적화)

  • Kang Seung-Won;Sun Tae-Hyoung;Chang Kyung-Hi;Lim In-Gi;Eo Ik-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.735-742
    • /
    • 2006
  • In this paper, we explain the operation scheme and fixed-point design method of DFE (Digital Front End), which performs DC offset compensation, automatic frequency control, and automatic gain control over the input signal to the UE (User Equipment) receiver of IEEE 802.16e OFDMA-TDD system. Then, we analyze the performance of DFE under ITU-R M. 1225 Veh-A 60km/h channel environment. To optimize the fixed-point design of DFE, we reduce the number of bit resulted from calculation without performance degradation, leading to the decreased complexity of the operation in H/W, and design the Loop filter with considering trade-off between the Acquisition time and the Stability.

A Design of Integral Sliding Mode Suspension Controller to Reject the Disturbance Force Acting on the Suspension System in the Magnetically Levitated Train System (자기부상 열차 시스템에서 추진 장치에서 발생하는 부상 간섭력의 영향을 제거하기 위한 적분형 Sliding Mode 부상 제어기 설계)

  • Lee, Jun-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1152-1160
    • /
    • 2007
  • In this paper we deal with a design of integral sliding mode controller to reject the disturbance force acting on the suspension system in the magnetically levitated system which is propelled by the linear induction motor. The control scheme comprises an integral controller which is designed for achieving zero steady-state error under step disturbances, and a sliding mode controller which is designed for enhancing robustness under plant uncertainties. A proper continuous design signal is introduced to overcome the chattering problem. The disturbance force produced by the linear motor is formularized by using a curve fitting of the experimental raw data. Computer simulations show the effectiveness of the designed integral sliding mode controller to reject the disturbance force.

Two-stage Adaptive Digital AGC Method for SDR Radio (SDR 통신장비를 위한 2단계 적응형 Digital AGC 기법)

  • Park, Jong-Hun;Kim, Young-Je;Cho, Jung-Il;Cho, Hyung-Weon;Lee, Young-Po;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.462-468
    • /
    • 2012
  • In this paper, an adaptive digital automatic gain control(AGC) algorithm with two stages is proposed. AGC technique is crucial for mobile communication equipment because path loss in wireless channel and gain fluctuation in receiver front-end continuously change the received signal strength. Furthermore, adaptive criteria should be applied to the design of AGC algorithm in order to support many waveforms with one SDR communication device. With these reasons, a two-stage structure is proposed to satisfy both flexibility and adaptiveness. Compared with conventional method, it also requires shorter convergence time. Numerical results show that the gain value of variable gain amplifier(VGA) is converged within proper time and proposed scheme controls the input level of analog to digital converter(ADC) to be stable during long range of time.

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.

A Fuzzy Traffic Controller with Asymmetric Membership Functions (비대칭적인 소속 함수를 갖는 퍼지 교통 제어기)

  • Kim, Jong-Wan;Choi, Seung-Kook
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.10
    • /
    • pp.2485-2492
    • /
    • 1997
  • Nowadays the traffic conditions have been getting worse due to continuous increase in the number of vehicles. So it has become more important to manage traffic signal lights efficiently. Recently fuzzy logic is introduced to control the cycle time of traffic lights adaptively. Conventional fuzzy logic controller adjusts the extension time of current green phase by using the fuzzy input variables such as the number of entering vehicles at the green light and the number of waiting vehicle during the red light. However this scheme is inadequate for an intersection with variable traffic densities. In this paper, a new FLC with asymmetric membership functions that reflects more exactly traffic flows than other FLCs with symmetric ones regardless of few control rules is propsed. The effectiveness of the proposed method was shown through simulation of a single intersection. The experimental results yielded the superior performance of the proposed FLC in terms of the average delay time, the number of passed vehicles, and the degree of saturation.

  • PDF

Digitalization of the Nuclear Steam Generator Level Control System (증기발생기 수위조절 시스템의 디지탈화)

  • Lee, Yoon-Joon;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.125-135
    • /
    • 1993
  • The safe and efficient operation of nuclear plants is recognized to be accomplished through the application of plant automation using digital technology, which is one of main targets of the next generation nuclear plants. For plant level automation, it is first required that each major subsystem be digitalized, and the steam generator water level control system is discussed in this study. The transfer functions between inputs and the level are derived by employing the thermal hydraulic model of the steam generator and are applied to the analysis of the current three-element control system. Since the control scheme in this study includes the steam generator itself as a process plant, the system order is high and the numerical instability arises in digitalizing. Together with this, the unreliability of the feedwater feedback signal at low power level leads to the proposal of a two-element control system with a proper digital controller. The digital PI controller developed for this system has the initial power adaptive gain and integration time constant. And it makes the overall system response satisfy the stability and other necessary control specifications simultaneously. Since the two-element control system using this controller depends on the initial power only, it is simple to define and it shows a similar level response behavior to that of its corresponding analog system.

  • PDF

A Study on Call Admission Control Scheme based on Multiple Thresholds in the CDMA System (CDMA시스템에서 다중 종류의 문턱치를 사용한 호 수락제어 기법에 대한 연구)

  • Piao, Shi-Gwon;Park, Yong-Wan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3A
    • /
    • pp.129-139
    • /
    • 2003
  • CAC is a very important issue in CDMA system in order to protect the required QoS(quality of service) and increase the system's capacity. In this paper, we proposed and analyzed a call admission control scheme using multiple thresholds, which can provide quick processing time and better performance. There are two effective thresholds used to decide call admission. One is the number of active users, and the other is the signal to interference ratio(SIR). If the threshold of active users are lower than the low number of users threshold, we accept the new call without any other conditions. Otherwise, we check the current SIR to guarantee the quality of our service. System then accepts the new call when the SIR satisfies system requirement. Otherwise, the call will be rejected. Multiple threshold schemes are investigated and their performance is compared with the number of user and power based CAC's. simulation results are provided to evaluate the performance.

Implementation of the BLDC Motor Drive System using PFC converter and DTC (PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.62-70
    • /
    • 2007
  • In this paper, the boost Power Factor Correction(PFC) technique for Direct Torque Control(DTC) of brushless DC motor drive in the constant torque region is implemented on a TMS320F2812DSP. Unlike conventional six-step PWM current control, by properly selecting the inverter voltage space vectors of the two-phase conduction mode from a simple look-up table at a predefined sampling time, the desired quasi-square wave current is obtained, therefore a much faster torque response is achieved compared to conventional current control. Furthermore, to eliminate the low-frequency torque oscillations caused by the non-ideal trapezoidal shape of the actual back-EMF waveform of the BLDC motor, a pre-stored back-EMF versus position look-up table is designed. The duty cycle of the boost converter is determined by a control algorithm based on the input voltage, output voltage which is the dc-link of the BLDC motor drive, and inductor current using average current control method with input voltage feed-forward compensation during each sampling period of the drive system. With the emergence of high-speed digital signal processors(DSPs), both PFC and simple DTC algorithms can be executed during a single sampling period of the BLDC motor drive. In the proposed method, since no PWM algorithm is required for DTC or BLDC motor drive, only one PWM output for the boost converter with 80 kHz switching frequency is used in a TMS320F2812 DSP. The validity and effectiveness of the proposed DTC of BLDC motor drive scheme with PFC are verified through the experimental results. The test results verify that the proposed PFC for DTC of BLDC motor drive improves power factor considerably from 0.77 to as close as 0.9997 with and without load conditions.