• Title/Summary/Keyword: side lobe

Search Result 305, Processing Time 0.027 seconds

Effect of Window Function for Measurement of Ultrasonic Nonlinear Parameter Using Fast Fourier Transform of Tone-Burst Signal (톤버스트 신호의 퓨리에 변환을 이용한 초음파 비선형 파라미터 측정에서 창함수가 미치는 영향)

  • Lee, Kyoung-Jun;Kim, Jongbeom;Song, Dong-Gi;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.251-257
    • /
    • 2015
  • In ultrasonic nonlinear parameter measurement using the fast Fourier transform(FFT) of tone-burst signals, the side lobe and leakage on spectrum because of finite time and non-periodicity of signals makes it difficult to measure the harmonic magnitudes accurately. The window function made it possible to resolve this problem. In this study, the effect of the Hanning and Turkey window functions on the experimental measurement of nonlinear parameters was analyzed. In addition, the effect of changes in tone burst signal number with changes in the window function on the experimental measurement was analyzed. The result for both window functions were similar and showed that they enabled reliable nonlinear parameter measurement. However, in order to restore original signal amplitude, the amplitude compensation coefficient should be considered for each window function. On a separate note, the larger number of tone bursts was advantageous for stable nonlinear parameter measurement, but this effect was more advantageous in the case of the Hanning window than the Tukey window.

A Case of Bronchiolar Papilloma (세기관지 유두종 1예)

  • Lee, Sang Hak;Kim, Chi Hong;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak;Jang, Eun Deok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.792-797
    • /
    • 1996
  • A 59-year-old woman was admintted to the hospital because of intermittent fever and right side chest pain. She has a same episode eight months before this entry. Chest CT scan demonstrated ill-defined parenchymal consolidation containing dilated bronchi of right lower lung field, but no endobronchial mass in the bronchial trees. Fiberoptic bronchoscopy seeking the cause of recurrent pneumonia revealed a small, round mass nearly completely obstructing me lumen of basal segmental bronchus of right lower lobe. The diagnosis of bronchiolar papilloma was made from the biopsy specimens of the bronchoscopic examination. The patient was treated with right lower lobectomy because of irreversible secondary changes below the obstructed bronchus. This thoracotomic excision resulted in complete relief of symptoms and the postoperative course was uneventful for 12 months. Here we report a extremely rare umor with a brief review of literatures.

  • PDF

Evaluation of Imaging Performance of Phase Shift Mask Depending on Reflectivity with Sub-resolution Assist Feature in EUV Lithography (SRAF를 적용한 극자외선 노광기술용 위상 변위 마스크의 반사도에 따른 이미징 특성 연구)

  • Jang, Yong Ju;Kim, Jung Sik;Hong, Seongchul;Cho, HanKu;Ahn, Jinho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.1-5
    • /
    • 2015
  • In photolithography process, resolution enhancement techniques such as optical proximity correction (OPC) and phase shift mask (PSM) have been applied to improve resolution. Especially, sub-resolution assist feature (SRAF) is one of the most important OPC to enhance image quality including depth of focus (DOF). However, imaging performance of the mask could be varied with the diffraction order amplitude changed by inserting SRAF. Therefore, in this study, we investigated the imaging properties and process margin of attenuated PSM with SRAF. Reflectivities of attenuated PSMs at 13.5 nm were 3, 6, 9% and simulation was performed by $PROLITH^{TM}$. As a result, aerial image properties and DOF as well as diffraction efficiency were improved by increasing the reflectivity of attenuated PSM. Additionally, printed critical dimension variations depending on SRAF width and space error were also reduced for attenuated PSM with high reflectivity. However, SRAF could be printed when reflectivity of attenuated PSM is high enough. In conclusion, optimization of reflectivity of attenuated PSM and SRAF to prevent side-lobe from being printed is needed to be considered.

Design of a Dual-Frequency Microstrip Patch Antenna (이중 공진형 마이크로스트립 패치 안테나 설계)

  • 김규성;김태우;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1131-1137
    • /
    • 1999
  • In this paper, a novel design method of an apertured coupled microstrip patch antenna with the single feeding structure is proposed for dual resonance frequencies with mutually perpendicular polarizations. The characteristics of this antenna are experimentally investigated. In order to achieve this goal, a new type of square patch with double notches is used as a radiator and the crossed slot and the bended mictrostrip feeder are adopted for the dual polarizations in the aperture-coupled structure. For the application of the proposed antenna, a Ku-band Tx/Rx $2\times$ subarray antenna is designed and manufactured. Also, the applicability of the antenna as a ground terminal is examined through performance analysis. According to the measurement, the gain of the antenna is 10dBi at the center frequencies of Tx and Rx, the side lobe level is lower than -13dB, and the cross polarization lebel is below 17 dB.

  • PDF

Effects on Performance of Deployable Solid Antenna for Panel Misalignment (패널오차에 의한 전개형 솔리드 안테나 성능 영향)

  • Lee, Ji-Yong;Lee, Kyo-Il;Yoon, Seong-Sik;Lee, Taek-Kyung;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.8
    • /
    • pp.603-609
    • /
    • 2017
  • In the deployable solid surface antennas, the effects on the performances of antenna due to the structural errors that occur during the deployment are analyzed. The deployable solid surface antennas employed in a satellite are launched in folded configuration and those are deployed in the space environment, and the effects on the antenna performance are calculated depending on the type of surface errors. When the deviation error occurs in one panel, the degradation of performance appears in the side where the incomplete deployment of panel occurs. By assuming that the panel error distribution is in cosine function, the effect of errors are calculated and analyzed with regard to the types and the magnitude of the error. If the antena panel error is uniform, the gain is reduced and pattern is symmetric. For the panel error of cosine 1 or 3 cycle, the main lobe tilts while the pattern is symmetric and the gain reduces for 2 or 4 cycle error.

An Analysis of characteristic response for Optical Directional Coupler with Perturbation Phenomenon (섭동 현상을 갖는 광 방향성 결합기의 응답 특성의 해석)

  • Kim Sun-youb;Park Hyoung-keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.353-359
    • /
    • 2006
  • As for the characteristic of elements for a lot of communication used in light communication systems, it is affected according to structure of directional coupler. We carried out study on a characteristic of the directional coupler which had waveguide structure to have perturbation phenomenon in this paper and ran simulation on the characteristic that we changed structure of directional coupler too, and was got. Confirmation was able to do that it operated with an optical filter, and the directional coupler which added waveguide structure to produce perturbation phenomenon by the results was able to confirm what we adjusted duty ratio of waveguide structure too, and operated with a more excellent optical filter. Through simulation, the case that duty ratio changed than the case that duty ratio of waveguide structure was $50\%$ was able to get an excellent answer characteristic of a -l8dB degree.

Pulmonary Vascular Changes in Systemic Pulmonary Anastomosis:An Experimental Study (폐동맥-쇄골하동맥 문합시의 폐동맥 변화에 관한 실험적 연구)

  • 박영관
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.91-106
    • /
    • 1970
  • Two groups of left pulmonary-subclavian artery anastomosis were done in 26 adult mongorel dogs. For the first group. the distal end of the subclnvian artery was nnastomosed to the side of the left pulmonary artery, and for the second group, the subclavian end wns anastomosed to the proximal end of the left lower lobe pulmonary artery. Among them, 6 died of bleeding or anesthetic failure during the day of operation, 10 survived 1 to 106 days and the other 10 were sacrificed at various interval. To investigate the relationship between hemodynamic stress and temporal evolution of the pulmonary vascular lesions. the pulmona try and femoral artery pressures, arteriogram and pathohistological specimens were obtained. The following results were obtained. 1. The postoperative pulmonary artery pressures were within normal limits except 2 dogs in the first group, but in nil 12 dogs of the second group, they were in moderate to maked pulmonary hypertension level. 2 After subclavian pulmonary anastomosis, both groups dogs showed increased femond artery pulse pressure. 3. The pulmonary vascular changes were more severe and appeared earlier in the second group dogs compared with the first group.4. The earliest vascular changes appeared in the media of the small muscular arteries and arterioles. 5. Various vascular chaDges were produced in 2 or 3 months. Thereafter, the changes were stationary. 6. Among the first group, two long-term servivors (No. 705 & 713) which had normal pulmonary artery pressure under the anesthesia, also showed various vascular changes as other pulmonary hypertensive dogs. 7. In the early stage medial hypertrophy. interruptio~l of elastic lamellae were found in the small muscular arteries and arterioles, which were followed by intimal proliferation and thrombosis. These findings may suggest some evidences of trauma to the vessels. 8. Pulmonary arteriograms showed irregularity of the intima of the large and medium sized arteries, abrupt ending of some of the small arteries and narrowing of the anastomosis.

  • PDF

Ultrastructure of the flagellar apparatus in Rhinomonas reticulata var. atrorosea (Cryptophyceae, Cryptophyta)

  • Nam, Seung Won;Go, Donghee;Son, Misun;Shin, Woongghi
    • ALGAE
    • /
    • v.28 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • Rhinomonas reticulata var. atrorosea G. Novarino is a photosynthetic marine flagellate that is known to have typical characteristics of cryptomonads. We examined the flagellar apparatus of R. reticulata var. atrorosea by transmission electron microscopy. The major components of the flagellar apparatus of R. reticulata var. atrorosea consisted of four types of microtubular roots (1r, 2r, 3r, and mr), a non-keeled rhizostyle (Rhs), mitochondrion-associated lamella (ML), two connections between basal bodies, a striated fibrous root (SR) and a striated fiber-associated microtubular root (SRm). Four types of microtubular roots originated near the ventral basal body and extended toward the left side of the basal bodies. The non-keeled Rhs originated at the Rhs-associated striated fiber, which was located between two basal bodies and extended into the middle of the cell. The ML was a plate-like fibrous structure associated with mitochondria and originating from a Rhs-associated fiber. It split into two parts and extended toward the dorsal-posterior of the cell to a mitochondrion. The SR and SRm extended parallel to the anterior lobe of the cell. The overall configuration of the flagellar apparatus in R. reticulata var. atrorosea was similar to the previously reported descriptions of those of Cryptomonas paramecium, C. pyrenoidifera, C. ovata, Hanusia phi, Guillardia theta, and Proteomonas sulcata. However, the flagellar apparatus system of R. reticulata var. atrorosea was more complex than those of other cryptomonad species due to the presence of an additional microtubular root and other distinctive features, such as a rhizostyle-associated striated fiber and large ML.

2×2Ti:LiNbO3 Integrated Optical Add/Drop Multiplexers utilizing Strain-Optic Effect (스트레인광학효과를 이용한 2×2Ti:LiNbO3 삽입/분기 집적광학 멀티플렉서)

  • Jung, Hong-Sik;Choi, Yong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.430-436
    • /
    • 2006
  • Polarization-independent $Ti:LiNbO_3\;2{\times}2$ optical add/drop multiplexer for the 1550nm wavelength region is fabricated. The device consists of two input waveguides, two polarization beam splitters. two polarization conversion/electrooptic tuning waveguide sections, and two output waveguides. The single mode channel waveguides for both TE and TM polarizations are fabricated on a x-cut $Ti:LiNbO_3$substrate by Ti diffusion. Spectral section is based on phase-matched polarization conversion due to shear strain induced by a thick $SiO_2$ grating overlay film. An applied voltage tunes the device by changing the waveguide birefringence, hence the optical wavelength at which most efficient polarization conversion occurs. Tuning rate of 0.094nm/V with a maximum range of 17nm has been obtained. The nearest side-lobe is about 8.2dB. The FWHM is 3.72nm.

Design of Sub-array Receiver for Active Phase Array Radar (능동위상배열 레이더 부배열 수신기 설계)

  • Yi, Hui-min;Kim, Do-hoon;Han, Il-tak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.5
    • /
    • pp.568-573
    • /
    • 2019
  • Modern Radars are evolving into MFRs which can search multiple targets simultaneously and then track them. Additionally they should be able to avoid some external jamming signals. Applying to these MFRs, Antennas should be able to perform DBF including to not only real-time beam steering but also multi-beam forming simultaneously. And they can cancel the beam at the specific direction. In this paper, we describe the implementation of sub-array type antenna hardware which can be applying DBF. Also we propose the modified amplitude aperture distribution for suppressing the side lobe level and explain the sub-array receiver design with amplitude tapering. It consists in making the amplitude weighting in 2 steps. In order to compare two weighting cases, we investigate the G/T performance for the array antenna. At the conclusion, we make a comparative study for the dynamic range of every sub-array receiver and present the hardware implementation that is more advantageous for sub-array alignment and calibration in DBF.