• 제목/요약/키워드: shutter

검색결과 235건 처리시간 0.024초

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

무안경식 다시점 입체 디스플레이를 위한 GPU기반 렌더링 기법 (A GPU based Rendering Method for Multiple-view Autostereoscopic Display)

  • 안종길;김진욱
    • 한국HCI학회논문지
    • /
    • 제4권2호
    • /
    • pp.9-16
    • /
    • 2009
  • 최근 3차원 입체 디스플레이에 대한 관심이 증가하고 있다. 무안경식 다시점 입체 디스플레이(Multiple-view Autostereoscopic Display)는 관찰자가 셔터 글래스(Shutter glasses)또는 HMD(Head Mounted Display)와 같은 특별한 장치를 착용하지 않고도 여러 시점(Multiple-view)에서 입체 영상을 볼 수 있어 가상현실(Virtual Reality), 모바일, 3D TV 등의 분야에서 각광 받고 있다. 하지만, 디스플레이 설계 시 정해진 거리와 시역 내에 관찰자가 위치해 있어야만 입체 영상을 볼 수 있다는 문제점이 있다. 본 연구에서는 무안경식 다시점 입체 디스플레이 시스템을 구축하여 이 시스템에서 관찰자의 시점 변경에도 실시간으로 자연스러운 3차원 입체 영상을 보여 주기 위한 효율적인 GPU기반 렌더링 기법을 제안한다.

  • PDF

Angiographic PIV 기법을 이용한 혈액유동의 in-vitro 연구 (In vitro application of Angiographic PIV technique to blood flows)

  • 김국배;임남윤;정성용;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.105-108
    • /
    • 2007
  • To diagnose the vascular diseases from the viewpoint of hemodynamics, we need detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique called 'Angiographic PIV system' consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for generating double pulse-type X-ray, and a synchronizer. Through several preliminary tests, the feasibility of the Angiographic PIV technique was verified. For in-vivo applications to real blood flows, we developed tracer microcapsules, which were optimized to this system, made of a contrast material of iodine and a matrix material of PVA (polyvinylpyrrolidone). In near future, the Angiographic PIV technique will be used for understanding hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

4K 초고속 카메라 촬영기술의 워크플로우에 관한 연구 (A Study on the Workflow of Cinematography with 4K High Speed Camera)

  • 김상일;박성철;김정호;권순철;이승현
    • 디지털콘텐츠학회 논문지
    • /
    • 제15권3호
    • /
    • pp.425-432
    • /
    • 2014
  • 4K 초고속 카메라 촬영은 해상도 및 셔터스피드 증가로 인해 빠른 피사체의 영상을 모션 블러 없이 Full HD 4배 해상도로 촬영이 가능하다. 그러나 해당 촬영은 데이터 량의 증가와 광량, 포커스 등 여러가지 제약사항이 뒤따른다. 증가된 셔터스피드로 인해 광량 부족 현상을 가져올 수 있어 조리개를 개방하여 촬영하는 경우가 많아 초점 조절에 제약이 따른다. 또한 증가된 해상도와 프레임레이트로 인해 저장 공간의 한계가 뒤따르기 때문에 촬영 기록에 제한이 따르고 있다. 따라서 본 연구는 4K 초고속 카메라(Phantom Flex 4K) 제작 사례를 통해 위와 같은 한계점들에 대해 분석하고, 이를 극복하기 위한 효율적인 워크플로우를 디자인 하였다.

동체의 순간 위치결정을 위한 수치영상 획득기법 개발 (Development of Digital Image Acquisition Technique for Momentary Positioning of Dynamic Object)

  • 한승희;강준묵
    • 대한공간정보학회지
    • /
    • 제4권2호
    • /
    • pp.47-54
    • /
    • 1996
  • 동체의 3차원 순간위치결정을 위해서는 동일시간에 획득한 2개 이상의 영상이 필요하다. 최근 대중화되고 있는 디지털 카메라를 이용할 수도 있겠으나 연속영상은 얻을 수 없으므로 본 연구에서는 이를 위하여 비디오카메라를 이용한 저가의 순간영상획득시스템을 구축하였다. 또한 동일한 시간대의 입체영상을 얻기 위하여 LCD타이머를 동체와 함께 촬영하고 얻어진 연속영상으로부터 비디오 편집기를 이용하여 독립수치영상을 얻었다. 그 결과 동일시간의 수치영상을 $788{\times}550$픽셀의 해상도로 얻을 수 있었고 1/100sec의 시간정확도로 획득한 동체상의 타겟을 검사 한 결과 양호하였다. 추후 3차원 위치정확도를 비교하기 위해 일반 측정용사진기로 B-shutter를 이용하여 동체를 촬영, 양호한 음화를 획득할 수 있었다.

  • PDF

이축 방향의 복합 자기 경로를 갖는 마그네트 기어 (Magnet Gear with Two-Axial Magnetic Paths)

  • 김문수;정광석
    • 한국정밀공학회지
    • /
    • 제31권6호
    • /
    • pp.543-550
    • /
    • 2014
  • A magnet gear composed of two layers of permanent magnets repeated circumferentially can transmit the power without mechanical contact. In the topology called by the magnet shutter gear known as the most competitive concept among the existing concepts, the number of pole-pairs on the high speed rotor corresponds to that of low speed rotor through electric steel set functioning as a magnetic modulator. The methodology is classified into radial type and axial type according to its magnetic path as in the motor. However, the magnetic modulator has multiple poles located separately. So, it is very complicated to assemble each module of the magnet gear mechanically and to sustain a mechanical stiffness of the modulator. The practical trouble can be solved partially through reconfiguring the modules. This paper deals with the novel magnetic shutter gear topology varying the magnetic path and its effectiveness is verified through real hardware implementation.

셔터렌즈에 의한 검출기 불균일 보정을 적용한 이중배율 적외선 카메라 설계 (Design of Two Zoom Infrared Camels using Noise Uniformity Correction by Shutter Lens)

  • 안규봉;김서현;정재철;조문신;김창우;김현숙
    • 한국광학회지
    • /
    • 제18권2호
    • /
    • pp.135-141
    • /
    • 2007
  • 완전한 2차원 배열을 갖는 중적외선 대역의 $320\times240$ 검출기를 사용하는 3세대 열상 장비의 설계 및 제작은 이차원 배열 검출기 제작 기술의 발달과 영상 신호처리 기술의 진전으로 인해 최근 더욱 더 활발히 이루어지고 있다. 본 논문은 다양한 응용 분야에서 적외선 센서로 사용될 수 있도록 하기 위하여 소형 경량화 제작을 목표로 한 3세대 열상장비의 이중 배율 적외선 카메라의 설계와 Defocus용 셔터 렌즈에 의한 영상기반 불균일 보정 방식에 대해 다룬다.

Dynamic Reconstruction of Anal Sphincter with Camera Shutter Style Double-Opposing Gracilis Flaps

  • Allen Wei-Jiat Wong;Grace Hui-Min Tan;Frederick Hong-Xiang Koh;Min Hoe Chew
    • Archives of Plastic Surgery
    • /
    • 제50권5호
    • /
    • pp.496-500
    • /
    • 2023
  • Fournier's gangrene is a life-threatening infection which requires prompt recognition, early surgical debridement of unhealthy tissue, and initiation of broad-spectrum antibiotics. Relook debridement are usually performed until all the devitalized tissue has been removed. Involvement of the anal sphincter may result in significant morbidity such as permanent incontinence. Dynamic reconstruction of the anal sphincter has always been one of the holy grails in the field of pelvic reconstruction. We demonstrate a new method of camera shutter style double-opposing gracilis muscle flaps that allows dynamic sphincteric function without the need for electrostimulation. The bilateral gracilis muscles are inset in a fashion that allows orthograde contraction of the muscle to narrow and collapse the neoanal opening. With biofeedback training, the patient is able to regain dynamic continence and return to function without a stoma. There was also no need for neurotization or microsurgery techniques to restore sphincteric function to the anus. The patient was able to reverse his stoma 14 months after the initial insult and reconstruction with biofeedback training without the use of electrostimulation.

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • 제62권2호
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

폰 카메라용 전자기력 Flapping 셔터 (Electromagnetic Flapping Shutters for Phone Cameras)

  • 최현영;한원;조영호
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1385-1391
    • /
    • 2010
  • 본 논문에서는 폰 카메라 응용을 위해 H 형 비틀림 스프링으로 지지된 한 쌍의 사다리꼴 셔터 블레이드를 이용하는 초소형, 저전력, 고속 전자기력 Flapping 셔터를 제안한다. 기존의 정전기력 Rolling 셔터와 Flapping 셔터는 폰 카메라 응용을 위해 큰 입력 전압이 필요하며, 기존의 전자기력 Rotating 셔터는 큰 부피로 인해 폰 카메라에 사용하기 어렵다. 본 논문에서 제안하는 전자기력 Flapping 셔터는 폰 카메라에 사용 가능한 작은 크기로 회전 구동을 위해 저강성 H 형 비틀림 스프링과 저관성 사다리꼴 블레이드로 설계하여 제작된다. 실험에서 전자기력 Flapping 셔터는 입력전류 60 mA 에서 자기장 0.15 T 와 0.30 T 에 대하여 각각 최대 오버슈트 회전각 $80.2{\pm}3.5^{\circ}$$90.0{\pm}1.0^{\circ}$와, 정상 상태 회전각 $48.8{\pm}1.4^{\circ}$$64.4{\pm}1.0^{\circ}$ 성능을 보인다. 응답 시간 성능에서는 셔터 개방의 경우, 1.0 ms/20.0 ms 의 상승/정착 시간을 보이며, 셔터 폐쇄의 경우는 1.7 ms/10.3 ms 의 하강/정착 시간을 보인다. 본 논문에서는 폰 카메라용 셔터 응용을 위해 제안하는 전자기력 Flapping 셔터의 초소형(${\sim}8{\times}8{\times}2\;mm^3$), 저전력(${\leq}60\;mA$), 고속(~1/370 s) 성능을 실험적으로 검증하였다.