• Title/Summary/Keyword: shunt coil

Search Result 41, Processing Time 0.025 seconds

Characteristics of a Coil type Fault Curent Limiters using a High-Tc Superconducting Thin Film (코일 형태로 제작한 박막형 고온초전도 전류제한기의 특성 해석)

  • Jeong, Dong-Cheol;Choe, Hyo-Sang;Park, Jong-Gwang;Im, Seong-Hun;Go, Geon-Mun;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.418-423
    • /
    • 2000
  • In this paper, we reported the current limiting properties of superconducting fault current limiters (SFCL). Our SFCL was patterned in a coil-type on a YBCO film deposited using rf sputtering techniques and was coated with a gold shunt layer in order to disperse the heat generated at hot spots in the YBCO film. Current increased up to 13.5 Apeak at 60 Hz for the voltage of 11.5 Vpeak, which is the minimum quench point, and increased up to 17.6 Apeak at 60 Hz for the voltage of 80 Vpeak. The quench completion time was 5 msec at 11.5 Vpeak and 4 msec at 80 Vpeak respectively. We think that this architecture using coil-type SFCL can be useful for the protection of the power delivery systems from fault currents.

  • PDF

Analyzed Model of The Active Filter combined with SMES

  • Kim A-Rong;Kim Jae-Ho;Kim Hae-Jong;Kim Seok-Ho;Seong Ki-Chul;Park Min-Won;Yu In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.20-24
    • /
    • 2006
  • Recently, utility network is becoming more and more complicated and huge due to IT and OA devices. In addition to, demands of power conversion devices which have non-linear switching devices are getting more and more increased. Consequently, because of the non-linear power semiconductor devices, current harmonics are unavoidable. Sometimes those current harmonics flow back to utility network and become one of the main reasons which can make the voltage distortion. Also, it makes noise and heat loss. On the other hands, voltage sag from sudden increasing loads is also one of the terrible problems inside of utility network. In order to compensate the current harmonics and voltage sag problem, AF(active filter) systems could be a good solution method. SMES is a very good promising source due to it's high response time of charge and discharge. Therefore, the combined AF and SMES system can be a wonderful device to compensate both harmonics current and voltage sag. However, SMES needs a superconducting magnetic coil. Because of using this superconducting magnetic coil, quench problem caused by unexpected reasons have always been unavoidable. Therefore, to solve out mentioned above, this paper presents a decisive method using shunt and series active filter system combined with SMES. Especially, authors analyzed the change of original energy capacity of SMES regarding to the size of resistance caused by quench of superconducting magnetic coil.

Fabrication and Characteristics of Integrated Nb DC SQUID (집적화된 Nb DC SQUID 소자의 제작 및 특성)

  • Lee, Yong-Ho;Gwon, Hyeok-Chan;Kim, Jin-Mok;Park, Jong-Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.277-281
    • /
    • 1992
  • We have designed, fabricated and tested an integrated planar DC SQUID which incorporates input coil and mofulation coil in thin film structure. The SQUID uses Nb /Al-oxide /Nb Josephson junctions and Pd shunt resistors, and the SQUID loop incorporates two rings connected in series forming figure '8' structure and has the advantage of a negligibly small circulating current for the spatially homogeneous noise fields. The devices were fabricated using photolithographic technique, RF magnetron sputtering, anodic oxidation for insulation and lift-off process. The preliminary test of the fabricated SQUID at 4.2 K showed that the flux-voltage characteristics were smooth enough to adopt standard readout system, and the voltage noise was too small to be measured by direct method and so the white noise was thought to be less than $10^{-4}\;{\phi}_o/\;\sqrt{H_z}$.

  • PDF

Fabrication and Fault Test Results of Bi-2212/Cu-Ni Tubes for Superconducting Fault Current Limiting Elements (Bi-2212/Cu-Ni 튜브로 제작한 초전도 한류소자의 단락사고시험 결과)

  • Oh, S.Y.;Yim, S.W.;Yu, S.D.;Kim, H.R.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.45-49
    • /
    • 2008
  • For the development of superconducting fault current limiters (SFCLs), fault current limiting elements were fabricated out of Bi-2212 bulk tubes and tested. The SFCL elements consisted of tube shaped Bi-2212 bulks and metal shunts for the stabilizers. Firstly, the Bi-2212 bulk tubes were processed based on a design of monofilar coils in order to acquire large resistance and high voltage rating. 300 mm-long Bi-2212 tubes were designed to have the current path of 410 cm in length with 24 turns and 41 mm in diameter. The processed monofilar coil, as designed, had 300 A $I_c$ at 77 K. The fabricated superconducting monofilar coils were affixed to Cu-Ni alloy as that of stabilizers. The Cu-Ni alloys were processed to have the same shape of the superconducting monofilar coils. The Cu-Ni coil had resistivity of 32 ${\mu}{\Omega}$-cm at 77 K and 37 ${\mu}{\Omega}$-cm at 300 K. The metal shunts were attached to the outside of the Bi-2212 monofilar coil by a soldering technique. After the terminals made of copper were attached to both ends of the superconductor-metal shunt composite, the gap between the turns and the surface of the elements was filled with an epoxy and a dense mesh made of FRP in order to enhance the mechanical strength. The completed SFCL elements went through fault tests, and we confirmed that the voltage rating of 143 $V_{rms}$ (E =0.35 $V_{rms}$/cm) could be accomplished.

  • PDF

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.

Two Case of Pulmonary Arteriovenous Fistula Treatment Depending on the Presence of Pulmonary Hypertension (폐동맥고혈압 동반여부에 따른 폐동정맥루의 치료)

  • Huh, Yun Jeong;Kim, Jeong Tae;Choi, Jae Young
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.216-220
    • /
    • 2005
  • Pulmonary arteriovenous fistulas(PAVFs) is a rare disorder that occurs in two to three children per 100,000 population. It is presented as absence of intervening capillary beds between the pulmonary artery and vein with resultant persistent right to left shunt. Other causes include trauma, liver cirrhosis, malignancy and schistosomiasis. It is mostly asymptomatic, but it may present with respiratory difficulty, cyanosis, clubbed fingers induced by right to left shunt or hemoptysis, polycythemia and epistaxis. Major complications, such as brain abscess, brain embolism, paradoxical embolism and subacute infective endocarditis can be devastating, so therapeutic intervention is recommended in all patients. However, removal of low-resistance fistulas can aggrevate pulmonary hypertension, so detection of increased pulmonary pressure is important. We report two patients : One a 42 year-old male with PAVFs treated with coil embolization, and a 42 year-old female who was treated with anticoagulants due to pulmonary hypertension.

Characteristic Analysis of Transformer Type SFCL with Shunt Resistance of Secondary Coil (변압기형 고온 초전도 전류제한기의 2차측 션트에 의한 특성 분석)

  • Choi, Byoung-Hwan;Du, Ho-Ik;Park, Chung-Ryul;Doo, Seung-Gyu;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.235-236
    • /
    • 2007
  • 변압기형 전류제한기는 1차측이 선로와 연결되어 있고 2차측은 고온 초전도 소자가 연결되어 있다. 사고 시 고온 초전도 소자의 부담을 줄이고자 2차측에 무유도 션트 저항을 연결하여 특성을 분석하였다. 션트가 없을 때 선로전류 제한율은 좋은나 2차측에 있는 초전도 소자가 부담해야하는 전력은 크다. 션트가 있을 때는 선로전류 제한율은 감소하는 반면 초전도 소자가 부당해야하는 전력은 크게 줄어들었다. 이때 2차측의 전압과 전류 중 전압의 감소 폭이 더 컸으며 션트저항 값이 작을수록 전압의 크기는 더 작아졌다. 결론적으로 션트저항의 연결에 따라 제한율은 낮아지지만 소자가 부담해야하는 전력은 크게 줄어든다.

  • PDF

Gain characteristics of SQUID-based RF amplifiers depending on device parameters

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.10-14
    • /
    • 2019
  • Radio-frequency (RF) amplifiers based on direct current (DC) superconducting quantum interference device (SQUID) have low-noise performance for precision physics experiments. Gain curves of SQUID RF amplifiers depend on several parameters of the SQUID and operation conditions. We are developing SQUID RF amplifiers for application to measure very weak RF signals from ultra-low-temperature high-magnetic-field microwave cavity in axion search experiments. In this study, we designed, fabricated and characterized SQUID RF amplifiers with different SQUID parameters, such as number of input coil turn, shunt resistance value of the junction and coupling capacitance in the input coil, and compared the results.

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.