• Title/Summary/Keyword: shunt

Search Result 1,335, Processing Time 0.023 seconds

A Filter Synthesis Method without Bandwidth Reduction for Dual-Band Filters Based on Coupled Lines (결합 선로 이중 대역 필터의 대역폭이 줄지 않는 설계 방법)

  • Lee, Seung-Ku;Ha, Jung-Je;Lee, Yong-Shik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • This paper proposes an improved filter synthesis method for dual-band filters based on coupled lines loaded with shunt stubs. The conventional design method relies on equality of the response of the conventional single-band filter and its dual-band counterpart at two frequencies. On the other hand, the proposed method is based on equivalence of the propagation constants and the image impedances of the two filters. Therefore, the proposed method does not suffer from bandwidth reduction phenomena, which requires complex compensating process in the conventional method. Also, the alternative design parameters provided by the demonstrated method enable to construct dual-band filters with more flexibility. For experimental verification, a Chebyshev type dual-band filter with center frequencies at 1 GHz and 3.5 GHz is designed and fabricated. The measured results are in excellent agreement with the full-wave simulated results.

A Case of Alagille's Syndrome (Alagille 증후군의 1예)

  • Kim, Sung-Eun;Choe, Won-Sick;Chun, Yong-Soon;Yoon, Hye-Kyoung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.154-158
    • /
    • 2000
  • This is a case report of a 5-month-old male who was brought in to hospital for evaluation of jaundice from birth. The baby had a history of ileal atresia operated 2 days after birth. At the age of one month, Tc-99m DISIDA hepatobiliary scintigraphy was performed at other hospital and reported to show good hepatic uptake of the tracer but no uptake in the biliary tree, gall bladder, or intestine for 24 hours post injection. He was judged to have biliary atresia. However, subsequent exploratory laparotomy revealed that the hepatobiliary tree appeared intact and that there was a gall bladder. Additionally, the patient had central aorto-pulmonary shunt for the right ventricular septal defect with pulmonary stenosis of a peripheral type at the age of 4 months. The second hepatobiliary scintigraphy was performed on admission at the age of 5 months, showing a gall bladder but no intestinal uptake up to 24 hours. Retrospectively, the histological specimen of the liver obtained at the exploratory laparotomy was re-evaluated, and by the histological findings coupled with clinical data, arteriohepatic dysplasia (Alagille's syndrome) was diagnosed. In this report, we emphasize the diagnostic limitation of hepatobiliary scintigraphy and the importance of overall clinical and histologic evaluation in a case of Alagille's syndrome.

  • PDF

A Novel Parameter Extraction Method for the Solar Cell Model (새로운 태양전지 모델의 파라미터 추출법)

  • Kim, Wook;Kim, Sang-Hyun;Lee, Jong-Hak;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.372-378
    • /
    • 2009
  • With the increase in capacity of photovoltaic generation systems, studies are being actively conducted to improve system efficiency. In order to develop the high performance photovoltaic power system it is required to understand the physical characteristics of the solar cell. However, solar cell models have a non-linear form with many parameters entangled and conventional methods suggested to extract the parameters of the solar cell model require some kind of assumptions, which accompanies the calculation errors, thereby lowering the accuracy of the model. Therefore, in this paper a novel method is proposed to calculate the ideality factor and reverse saturation current of the solar cell from the I-V curve measured and announced by solar cell manufacturers, derive the ideal I-V curve, and then extract the series and shunt resistances value from the difference between the ideal and measured I-V curve. Also, validity of the proposed method is demonstrated by calculating the correlation between I-V curve based on modeling parameters and I-V curve actually measured through least squares method.

The fabrication of ITO/p-InP solar cells (ITO/p-InP 태양전지 제작)

  • 맹경호;김선태;송복신;문동찬
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.243-251
    • /
    • 1994
  • ITO(Indium Tin Oxide) film with thickness of 1500.angs. was prepared by an e-beam evaporator onto a glass and a p-type InP wafer (100) LEC grown Zn-doped p=2.3*10$\^$16/cm$\^$-3/), in which the components of ITO used for evaporation source were hot pressed pellets 1 mole% ln$\_$2/O$\_$3/+9 mole% SnO$\_$2/, and evaporated in O$\_$2/ ambient. The optimum conditions to preparation of ITO thin film were the substrate temperature of 350.deg. C, the injected oxygen pressure of 2*10$\^$-4/ torr, and the evaporation speed of 0.2-0.3.angs./sec, respectively. In these optimum conditions, the resistivity and the carrier concentration were 5.3*10$\^$-3/ .ohm.-cm, 6.5*10$\^$20/cm$\^$-3/, and the transmittance was over 80%. From the results of J-V measurements in ITO/p-InP structure solar cells, the higher pressure of injected oxygen, the more open circuit voltage. The efficiency of ITO/p-InP solar cell without the grid line contact, prepared by the optimum evaporation conditions, was 7.19%. By using the grid line contact, the efficiency, the open circuit voltage, the short circuit current density, the fill factor, the series resistance, and the shunt resistance were 8.5%, 0.47V, 29.48 mAcm$\^$-2/ , 61.35%, 3.ohm., and 26.6k.ohm., respectively.

  • PDF

Heterologous Expression of a Model Polyketide Pathway in Doxorubicin-overproducing Streptomyces Industrial Mutants (방선균 항생제 고생산 산업균주를 기반으로 한 모델 폴리케타이드의 이종숙주 발현)

  • Kim, Hye-Jin;Lee, Han-Na;Kim, Eung-Soo
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.1
    • /
    • pp.10-16
    • /
    • 2012
  • The Streptomyces peucetius OIM (Overproducing Industrial Mutant) strain is a recursively-mutated and optimally-screened strain used for the industrial production of polyketide antibiotics, such as doxorubicin (DXR). Using the S. peucetius OIM mutant strain as a surrogate host, a model minimal polyketide pathway for aloesaponarin II, an actinorhodin shunt product, was cloned in a high-copy conjugative plasmid, followed by functional pathway expression and quantitative metabolite analysis. The level of aloesaponarin II production was noted as being significantly higher in the OIM strain than in the wild-type S. peucetius, as well as in the regulatory network-stimulated S. coelicolor mutant strain. Moreover, the aloesaponarin II production level was seen to be even higher in a down-regulator $wblA_{spe}$-deleted S. peucetius OIM strain, implying that the rationally-engineered S. peucetius OIM mutant strain could be used as an efficient surrogate host for the high expression of foreign polyketide pathways.

Design and Fabrication of a LTCC Diplexer for GSM/CDMA Applications (GSM/CDMA 대역용 LTCC Diplexer설계 및 제작)

  • Kim, Tae-Wan;Lee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1267-1271
    • /
    • 2009
  • In this paper, a diplexer circuit to separate GSM from CDMA band is designed using a LTCC (Low Temperature Cofired Ceramic) multi-layer technology. In order to increase a integration capability of the diplexer, it is designed using 3-dimensional (3-D) multi-layer compact inductor and capacitors in e-layer LTCC substrate with a relative dielectric constant of 7. In order to achieve high selectivity of the bands, a shunt capacitor and inductor are designed in the high-pass filter (HPF) and low-pass filter (LPF), respectively. The size of the fabricated diplexer including CPW pads is 3,450 ${\times}$4,000 ${\times}$694 ${\mu}m^3$An insertion loss (IL) and return loss in GSM band are less than -1.35dB and more than -5.66dB,respectively. In the case of CDMA band, the IL of -1.54dBandRLof above -9.30dBare archived.

Design of the Robust Active Power Filter under the Unbalanced and Distorted Source Voltages in Three-phase Four-wire Systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min Joon-Ki;Kim HyoSung;Choi Jaeho;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • This paper proposes a novel current control strategy on active power filters using PQR instantaneous power theory which can compensate the line current harmonics and the neutral line current under the unbalanced and/or distorted source conditions in three-phase four-wire systems. The characteristics of the inverter ac filters are analyzed and a novel digital controller are proposed to overcome the inherent time delay problem in digital controllers with designed control gain in this paper. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation compared with a conventional hysteresis PWM. PSiM simulation results verify the good performance of the proposed current control strategy on shunt type APFs.

Low Reverse Saturation Current Density of Amorphous Silicon Solar Cell Due to Reduced Thickness of Active Layer

  • Iftiquar, S M;Yi, Junsin
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.939-942
    • /
    • 2016
  • One of the most important characteristic curves of a solar cell is its current density-voltage (J-V) curve under AM1.5G insolation. Solar cell can be considered as a semiconductor diode, so a diode equivalent model was used to estimate its parameters from the J-V curve by numerical simulation. Active layer plays an important role in operation of a solar cell. We investigated the effect thicknesses and defect densities (Nd) of the active layer on the J-V curve. When the active layer thickness was varied (for Nd = 8×1017 cm-3) from 800 nm to 100 nm, the reverse saturation current density (Jo) changed from 3.56×10-5 A/cm2 to 9.62×10-11 A/cm2 and its ideality factor (n) changed from 5.28 to 2.02. For a reduced defect density (Nd = 4×1015 cm-3), the n remained within 1.45≤n≤1.92 for the same thickness range. A small increase in shunt resistance and almost no change in series resistance were observed in these cells. The low reverse saturation current density (Jo = 9.62×10-11 A/cm2) and diode ideality factor (n = 2.02 or 1.45) were observed for amorphous silicon based solar cell with 100 nm thick active layer.

Preliminary study on the quench protection of Bi-22231 Ag tape using superconducting fault current limiter (초전도 한류기를 이용한 Bi-2223/Ag 선재의 퀜치 보호를 위한 기초 연구)

  • Du, Ho-Ik;Yim, Seong-Woo;Hyun, Ok-Bae;Hwang, Si-Dole;Cho, Chul-Yong;Park, Chung-Ryul;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.243-244
    • /
    • 2006
  • As an preliminary study for the quench protection of high temperature superconducting (HTS) cable using superconducting fault current limiter (SFCL), experimental research was carried out. The test circuit was composed of Bi-2223/Ag HTS tape and a SFCL made of YBCO thin films. In the normal state, the applied current of 56 A, which was critical current of HTS tape, could be flown through the circuit without resistive loss. Increasing the currents, the quench development of both materials was investigated from the voltage signal acquired from the resistance of the quenched superconductor. Up to around 10 times of the critical current was applied to the HTS tape and the current limiting characteristics of SFCL were investigated. In addition, for the finding out the optimal operating condition of SFCL such as the numbers of elements, a shunt resistor was applied to the SFCL and quench characteristics were analyzed as well.

  • PDF

Aortoplasty with Using Gore-Tex Conduit in Dissecting Aneurysms of Descending Thoracic Aorta - Two Cases Report - (GoreTex$^{\circledR}$ 인조혈관을 이용한 해리성 하행 흉부대동맥류 성형술 - 수술치험 2례 -)

  • 정진용
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.816-822
    • /
    • 1989
  • Aneurysms of the descending thoracic aorta can be caused by various etiologies. So, its abrupt rupture leads life-threatening state, it must be operated as soon as possible. Surgical treatment of the descending thoracic aortic aneurysm requires temporary cross-clamping of major artery. The obligatory occlusion of the descending thoracic aorta during management causes proximal arterial hypertension and distal arterial hypotension. The former may leads to left ventricular failure, or cerebrovascular accident, whereas the latter may leads to spinal cord ischemia or renal injury. Some have recommended insertion of temporary shunt around the occluded descending aorta to prevent above problems. Still others would favor expeditious operation employing simple aortic occlusion during the repair of the descending aorta. Recently we had experienced two cases of dissecting aneurysms of descending thoracic aorta which performed aortoplasty with Gore-Tex conduit under simple aortic occlusion. The one was 34-year-old female patient with traumatic dissecting aortic aneurysm [5 em X 5 cm] on the descending thoracic aorta distal to the origin of the left subclavian artery and the other was 58-year-old female patient with atherosclerotic dissecting descending thoracic aortic aneurysm [6 cmX7 cm] and diffuse abdominal aortic aneurysms [3X5 cm]. Both patients performed standard left posterolateral thoracotomy. After the aneurysmal sac was mobilized, occluding vascular clamps were placed on the transverse aorta proximal to the origin of the left subclavian artery, and on the distal descending aorta without adjuvant bypass procedures for 31 and 32 minutes, respectively, and the aneurysmal sac was repaired with 18 mm ringed Gore-Tex conduit graft. Both patients postoperative courses were uneventful.

  • PDF