• 제목/요약/키워드: shorted turn

검색결과 38건 처리시간 0.027초

Winding Fault Diagnosis of Induction Motor Using Neural Network

  • Song Myung-Hyun;Park Kyu-Nam;Woo Hyeok-Jae;Lee Tae-Hun;Han Min-Kwan
    • Journal of information and communication convergence engineering
    • /
    • 제3권2호
    • /
    • pp.105-109
    • /
    • 2005
  • This paper proposed a fault diagnosis technique of induction motors winding fault based on an artificial neural network (ANN). This method used Park's vector pattern as input data of ANN. The ANN are firstly learned using this pattern, and then classify between 'healthy' and 'winding fault' (with 2, 10, and 20 shorted turn) induction motor under 0, 50, and $100\%$ load condition. Also the possibility of classification of untrained turn-fault and load condition are tested. The proposed method has been experimentally tested on a 3-phase, 1 HP squirrel-cage induction motor. The obtained results provided a high level of accuracy especially in small turn fault, and showed that it is a reliable method for industrial application

발전기 회전자 감시용 센서의 효과적인 설치방법 고찰 (A study on Effetive Installation Method for Shorted-Turn Sensor)

  • 이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1619-1620
    • /
    • 2011
  • 본 논문에서는 발전소 현장에서 전력을 생산하는 발전기의 중요 구성품인 회전자 계자권선의 단락 현상을 감지할 수 있는 센서를 개발하여 현장 발전기에 설치함에 있어, 설치시 발생할 수 있는 문제점으로 인해 센서가 제 기능을 발휘하지 못하는 것을 사전에 차단하고자, 그동안 현장설치시 나타난 문제점을 고찰하고 향후 발전기 내에 단락 감시용 센서 설치시 이러한 문제점이 발생하지 않도록 효과적인 설치방법에 대하여 기술하였다.

  • PDF

발전기 운전중 종합 진단시스템 개발 (Development of On line Diagnosis System for Generator)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.975-977
    • /
    • 2005
  • The generator on-line diagnosis system has been developed. This system monitor the insulation condition of stator winding by on-line measurements of partial discharge and the shorted-turn condition of rotor winding by on-line measurements of slot leakage flux. Sensor, such as SSC(Stator Slot Coupler) and flux probe are used for generator on-line diagnosis.

  • PDF

저전압 펄스신호를 이용한 발전기 회전자 턴단락 진단 (Shorted-Turn Diagnosis Test for Generator Rotor Windings using Low Voltage Pulse Signal)

  • 이영준;김병래;황영하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2019_2020
    • /
    • 2009
  • A recurrent surge oscillograph(RSO) test was performed at the Taean thermal power plant on #5 turbine generator. The test was conducted using a rotor reflectometer and digital oscilloscope. A DC voltage step is applied to each end of the rotor winding in turn. Each reflected wave, at the input end of the winding, is monitored and the two waveforms are superimposed automatically and monitored on a single channel oscilloscope. As the half windings in a rotor are identical, the two waveforms monitored at each end of the rotor will also be identical for a healthy winding. A winding with a fault will cause different voltages to be monitored at the two ends.

  • PDF

Park's Vector Approach의 위상각 변이를 활용한 유도전동기 고정자 고장진단 (A Stator Fault Diagnosis of an Induction Motor based on the Phase Angle of Park's Vector Approach)

  • 고영진;이범;송명헌;김경민
    • 제어로봇시스템학회논문지
    • /
    • 제20권4호
    • /
    • pp.408-413
    • /
    • 2014
  • In this paper, we propose a fault diagnosis method based on Park's Vector Approach using the Euler's theorem. If we interpreted it as Euler's theorem, it is possible to easily find the phase angle difference between the healthy condition and the fault condition. And, we analyzed the variation of the phase angle and performed the diagnostic method of the induction motor using feature vectors that were obtained by using a Fourier transform. The analysis of time and speed variation of the motor was performed and, as a result, we could find more soft variations than rough variations. In particular, the analysis of the distortion through each phase shows that two-turn and four-turn shorted motors are linearly separable. In this experiment, we know that the maximum breakdown threshold value for determining steady-state fault detection is 49.0788. Simulation and experimental results show the more detectable than conventional method.

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

발전기 회전자 권선 층간단락 진단에 관한 연구 (Shorted-Turn Test for Generator Rotor Windings)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1747-1749
    • /
    • 2003
  • 발전기 회전자 권선에 종종 발생하는 층간단락 현상을 찾아내는 진단기법에는 크게 두가지가 있으며, 정지중 진단기법인 분담전압 시험과 운전중 진단기법인 flux probe 시험이다. 본 논문에서는 서인천복합화력발전소 #2 스팀터빈 발전기에 대하여 분담전압 및 flux probe 시험을 시행하여 회전자 권선의 건전성을 확인하고, 그 결과를 상호 비교, 분석하여 정지중 및 운전중 진단기법의 신뢰성을 평가하였다.

  • PDF

권선 단락 및 스위치 개방 고장 시의 인버터 구동 영구자석 동기전동기의 고장 진단 기법 (A Fault Diagnosis Technique of an Inverter-fed PMSM under Winding Shorted Turn and Inverter Switch Open Fault)

  • 김경화
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.94-105
    • /
    • 2010
  • 인버터 구동 영구자석 동기전동기에서 고정자 권선과 인버터 스위치에 고장이 존재할 때 동작 중 실시간으로 고장을 검출하고 고장의 유형을 판별할 수 있는 진단 기법이 제시된다. 제안된 기법은 q축 전류의 2차 고조파를 실시간으로 관찰함으로써 이루어지며 고장이 없는 정상 조건에서의 고조파 데이터와 비교를 통해서 고장을 판별한다. 임의의 정상 동작 조건에서의 고조파 데이터는 선형 보간법을 이용해 구해진다. 고장 검출 시 진단 알고리즘은 고장 유형 판별모드로 전환되어 상전류의 파형 분석을 통해 고장의 유형을 판별한다. 제안된 고장 검출 기법의 타당성을 입증하기 위해 내부 권선 단락이 가능한 전동기가 제작되었으며 전체 시스템과 고조파 분석 및 고장 검출 알고리즘이 DSP TMS320F28335에 의해 구현된다. 제안된 방법은 부가적인 진단 장비를 요구하지 않으며 정상상태 조건이 만족된다면 동작 중 실시간으로 고장을 검출할 수 있다.