• 제목/요약/키워드: short through ratio

검색결과 303건 처리시간 0.031초

단락시간비를 이용한 GMAW의 비드 높이 제어에 관한 연구 (A Study on Bead Height Control of GMAW by Short Circuit Time Ratio)

  • 감병오;조상명;김상봉
    • 한국해양공학회지
    • /
    • 제16권2호
    • /
    • pp.53-59
    • /
    • 2002
  • This paper shows the experimental results controlling the height of surface and back bead in GMAW by analyzing the unexpected gaps between base metals produced in welding and by controlling welding velocity due to the variation of the gap between base metals in thin-plate welding. The back bead behavior and burn-through in I-type butt joint $CO_2$ welding of thin mild steel are analyzed in the views of short circuit time ratio and short circuit frequency. It is shown through experimental consideration that the short circuit time ratio method is more reasonable than the short circuit frequency method in analyzing the formulation of back bead under changing the gap between base metals. Based on the these results, welding manipulator is designed so as to satisfy the bead height control in real time by measuring the short circuit time ratio. To show the effectiveness of the developed bead formulation control system, the experiment is implemented under two welding conditions such as increasing gap from 0mm to 0.8mm and gradually increasing gap from 0mm to 1.2mm. The experimental results show that the bead formulation can be controlled uniformly in spite of the variation of the gap between base metals.

Proposal for a virtual museum with vertical aspect ratio for the convergence of metaverse and short-form content

  • Il-hyun Cho
    • International journal of advanced smart convergence
    • /
    • 제12권3호
    • /
    • pp.119-126
    • /
    • 2023
  • This study explores the convergence of metaverse and short-form content, proposing a new approach for viewing short-form content with a vertical aspect ratio on a metaverse platform and within a virtual museum. Short-form content has gained popularity due to the snack culture and is proving to be advantageous in e-commerce. By studying the relationship between vertical ratio screens and gaze, we confirm the effectiveness of vertical ratio short-form content in providing immersive experiences and fostering sharing and communication. The proposed virtual museum offers opportunities for innovative businesses to market through fandom. This research highlights the value of vertical proportion short-form content and its significance in the convergence of metaverse and short-form content. It aims to contribute to industry development, provide new creative directions, enhance personal visual experiences, and expand applicability in related fields.

Seismic performance of RC columns with full resistance spot welding stirrups

  • Yu, Yunlong;Dang, Zhaohui;Yang, Yong;Chen, Yang;Li, Hui
    • Structural Engineering and Mechanics
    • /
    • 제73권5호
    • /
    • pp.543-554
    • /
    • 2020
  • This paper aims to investigate the seismic performance of RC short columns and long columns with welding stirrups. Through the low-cyclic horizontal loading test of specimens, the seismic performance indexes such as failure modes, hysteretic curve, skeleton curve, ductility, energy dissipation capacity, stiffness degradation and strength degradation were emphatically analyzed. Furthermore, the effects of shear span ratio, stirrups ratio and axial compression ratio on the performance of specimens were studied. The results showed that the seismic performance of the RC short columns with welding stirrups were basically the same as that of the RC short columns with traditional stirrups, but the seismic performance of RC long columns with welding stirrups was better than that of RC long columns with traditional stirrups. The seismic performance of RC short columns and long columns with welding stirrups could be improved by increasing stirrup ratio and shear span ratio and reducing axial pressure ratio. Moreover, the welding stirrup have the advantages of steel saving, industrialization and standardization production, convenient construction, and reducing time, which indicated that the welding stirrups could be applied in practical engineering.

피크전류제한 설정에 따른 피크전류제한 기능을 갖는 자속구속형 초전도한류기의 고장전류제한 특성 분석 (Analysis on Fault Current Limiting Characteristics According to Peak Current Limiting Setting of a Flux-Lock Type SFCL with Peak Current Limiting Function)

  • 고석철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.68-73
    • /
    • 2012
  • In this paper, the fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) with peak current limiting function were analyzed through its short-circuit tests. The setting condition for the peak current limiting operation was derived from its electrical equivalent circuit, which was dependent on the inductance ratio between the third coil and the first coil. Through the analysis on the short-circuit tests for the flux-lock type SFCLs with the different inductance ratio between the third coil and the first coil, the setting value for the peak current limiting operation of the flux-lock type SFCL with peak current limiting function could be confirmed to be adjusted with the variation of the inductance ratio between the third coil and the first coil.

Seismic performance of RC short columns with light transverse reinforcement

  • Tran, Cao Thanh Ngoc;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.93-104
    • /
    • 2018
  • The seismic behavior of reinforced concrete (RC) short columns with limited transverse reinforcement is investigated in this paper through an experimental program. The experimental program consists of four small-scale RC columns with an aspect ratio of 1.7, which are tested to the axial failure stage. The cracking patterns, hysteretic responses, strains in reinforcing bars, displacement decomposition and cumulative energy dissipation of the tested specimens are reported in detail in the paper. The effects of column axial load are investigated to determine how this variable might influence the performance of the short columns with limited transverse reinforcement. Brittle shear failure was observed in all tested specimens. Beneficial and detrimental effects on the shear strength and drift ratio at axial failure of the test specimens due to the column axial load are found in the experimental program, respectively.

Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1789-1794
    • /
    • 2014
  • This paper suggests an application method for a superconducting fault current limiter (SFCL) using an evaluation index to estimate the risk regarding the short-circuit capacity of the circuit breaker (CB). Recently, power distribution systems have become more complex to ensure that supply continuously keeps pace with the growth of demand. However, the mesh or loop network power systems suffer from a problem in which the fault current exceeds the short-circuit capacity of the CBs when a fault occurs. Most case studies on the application of the SFCL have focused on its development and performance in limiting fault current. In this study, an analysis of the application method of an SFCL considering the risk of the CB's short-circuit capacitor was carried out in situations when a fault occurs in a loop network power system, where each line connected with the fault point carries a different current that is above or below the short-circuit capacitor of the CB. A loop network power system using PSCAD/EMTDC was modeled to investigate the risk ratio of the CB and the effect of the SFCL on the reduction of fault current through various case studies. Through the risk evaluations of the simulation results, the estimation of the risk ratio is adequate to apply the SFCL and demonstrate the fault current limiting effect.

저단락비 HVDC 시스템에서웨 무효편력수급 최적 방안 연구 (Study on Optimized Scheme of Reactive Power Compensation for Low Short-Circuit-Ratio HVDC System)

  • 백승택;한병문;오세승;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.434-440
    • /
    • 2005
  • This paper describes an optimized Scheme of reactive-power compensation for the low short-circuit-ratio AC system interconnected with the HVDC system. An HVDC system interconnected with tile low SCR AC system is vulnerable to the ac voltage variation, which brings about the commutation failure of the converter. This problem can be solved using optimized compensation of reactive power. In this study, a benchmark system for HVDC system interconnected with low SCR AC system is derived using PSS/E simulation. Then an optimized srheme for reactive power compensation was derived using integer programming. The feasibility of proposed scheme was analyzed through silnulations with PSS/E and PSCAD/EMTDC. The proposed scheme can compensate the reactive power accurately and minimize the number of switching for harmonic filters and shunt reactors.

유도전동기의 권선 단락 상에 따른 팍스 벡터 패턴 왜곡률의 영향 해석 (Interpretation of Influence Winding Short Phase of Induction Motor to Distortion Ratio of Park's Vector Pattern)

  • 양철오;김종선;김준영;박규남;송명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2075-2076
    • /
    • 2011
  • The stator winding faults diagnosis technique based on MCSA is as follows. Firstly, collecting the 3 phase motor currents, that signal is transformed by (d-q transform, $i_d$, $i_q$). Park's vector pattern, the circle that is down by d-q transformed currents($i_d$, $i_q$). The circle is widely used for stator winding faults detection. The current distortion ratio(DR), defined by the ratio of max-axis and min-axis of ellipse of Park's vector's pattern. In this study, distortion ratio of Park's vector pattern is suggested for Auto diagnosis of stator winding short fault and usefulness of distortion ratio is verified through simulation using LabVIEW program.

  • PDF

대구지역의 고도와 위치에 따른 하절기 장·단파복사 관측과 해석 (Observation and Analysis of the Long and Short Wave Radiation According to Different Altitudes and Locations in Daegu During Summer)

  • 최동호;이부용;오호엽
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.71-81
    • /
    • 2012
  • This study for the understanding of the radiation environment according to the altitude in urban area in the summer observes the long and short wave radiation environment at the 4 urban areas with different height and the 1 suburban area. The results of this study are as follows. (1) When the altitude was high, the more short wave radiation was observed. (2) As the altitude was high, the temperature of atmosphere got lower. And because of that the downward long wave radiation was also lower. This general trend was confirmed through the study. (3) Through the observation of long wave radiation, the upper atmosphere of suburban area had the atmosphere characteristic which the temperature was rising and decreasing faster. Therefore, the difference radiation characteristics between the urban and suburban area were confirmed. (4) The result of the ratio of short wave radiation to long wave radiation(short wave radiation/long wave radiation) according to the altitude and location, the value was increased when the distance was far from the artificiality structure or a heat source, and the urban effect became smaller. Thus, it is expected that the ratio will be an evaluation index for evaluating urbanization effect.

Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구 (A Study on Future System Construction Using WSCR Strengthness Index based on Python)

  • 박성준;허진;김현진;조윤성
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.