• Title/Summary/Keyword: short test

Search Result 3,371, Processing Time 0.035 seconds

A Novel Testing Method for Operational Amplifier Using Offset and High Frequency (오프셋과 고주파수를 이용한 연산증폭기의 새로운 테스트 방식)

  • 송근호;백한석;문성룡;서정훈;김강철;한석붕
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.189-192
    • /
    • 2000
  • In this paper, we propose the novel test method to detect short and open faults in CMOS Op-amp. The proposed method is composed of two test steps - the offset and the high frequency test. Using HSPICE simulation, we get a 100% fault coverage. To verify the proposed method, we design and fabricate the CMOS op-amp that contains various short and open faults through Hyundai 0.65$\mu\textrm{m}$ 2-poly 2-metal CMOS process. Experimental results of fabricated chip demonstrate that the proposed test method can detect short and open faults in CMOS Op-amp.

  • PDF

Artificial line for short-line fault test (근거리선로고장전류 차단시험용 Artificial line)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1783-1785
    • /
    • 2001
  • With the 4-MJ synthetic testing facilities completed, KERI can perform the circuit breaker testing up to 420 kV, 50 kA ratings. The short-line fault test is one of the necessary test items which are required for the circuit breaker, and in order to perform the short-line fault test KERI(Korea Electrotechnology Institute) has used the "new artificial line" which has small dimension and is easy to generate the saw-tooth wave. This paper describes the following items of the new artificial line. -Description of 4-kinds of artificial lines and determination of the circuit parameter of artificial line. -TRV characteristics of saw-tooth waves for each circuit. -KERI's artificial line.

  • PDF

Design and Implementation of the Automatic cable assembly test system that can test cable assembly effectively

  • Jang, Ki-Mang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.1-10
    • /
    • 2018
  • In this paper, we propose the principles and design details of Automatic cable assembly test system and show its utility. Testing the cable assembly is required periodically or non-periodically in the system that the cable assembly performance is quite important like military equipment. There are several weaknesses when humans test the cable assembly manually. It not only takes much time but also could happen human error. To improve these disadvantages, I developed Automatic cable assembly test system. The system can be implemented by building switching control system that connect and disconnect the cable assembly and measuring devices. Through the result of the cable assembly test with this test system, we show this system makes test time short and improves of test reliability as compared with manual test.

Shear behavior of short square tubed steel reinforced concrete columns with high-strength concrete

  • Li, Xiang;Zhou, Xuhong;Liu, Jiepeng;Wang, Xuanding
    • Steel and Composite Structures
    • /
    • v.32 no.3
    • /
    • pp.411-422
    • /
    • 2019
  • Six shear-critical square tubed steel reinforced concrete (TSRC) columns using the high-strength concrete ($f_{cu,150}=86.6MPa$) were tested under constant axial and lateral cyclic loads. The height-to-depth ratio of the short column specimens was specified as 2.6, and the axial load ratio and the number of shear studs on the steel shape were considered as two main parameters. The shear failure mode of short square TSRC columns was observed from the test. The steel tube with diagonal stiffener plates provided effective confinement to the concrete core, while welding shear studs on the steel section appeared not significantly enhancing the seismic behavior of short square TRSC columns. Specimens with higher axial load ratio showed higher lateral stiffness and shear strength but worse ductility. A modified ACI design method is proposed to calculate the nominal shear strength, which agrees well with the test database containing ten short square TSRC columns with shear failure mode from this study and other related literature.

The Effects of Interactive Metronome on Short-term Memory and Attention for Children With Mental Retardation (상호작용식 메트로놈(Interactive Metronome: IM) 훈련이 지적장애 아동의 집중력과 단기기억력에 미치는 영향)

  • Bak, Ah-Ream;Yoo, Doo-Han
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.14 no.1
    • /
    • pp.19-30
    • /
    • 2016
  • Objective : The purpose of this study was to identify the effects of Interactive Metronome (IM) training on short-term memory and attention for children with mental retardation. Methods : For this study, single-subject experimental research was conducted using an ABA design. We observed two children, twice a week for 9 weeks, which was 18 sessions in total. We evaluated the children's brain waves without intervention and the child's pseudo randomly selected sample of one short-term memory task as assessed in the baseline A phase for three sessions. In the intervention phase the children received 40-50 minutes of Interactive Metronome training twice a week, a total of 12 sessions. The short-term memory test and long form test as assessed after treatment, without brain wave in short form test measuring. During the baseline A phase, data were collected using the same procedure as the baseline A phase. Results : After the interactive metronome training, positive changes was observed in brain waves, attentions and short-term memory. Conclusion : The results of this study expect that IM training has a potential for improving cognitive functions of children with mental retardation. In addition, the results of this study can be used as basic data in attention and short-term memory of occupational therapy intervention for children with mental retardation.

Short-circuit Protection Circuit Design for SiC MOSFET Using Current Sensing Circuit Based on Rogowski Coil (Rogowski Coil 기반의 전류 센싱 회로를 적용한 SiC MOSFET 단락 보호 회로 설계)

  • Lee, Ju-A;Byun, Jongeun;Ann, Sangjoon;Son, Won-Jin;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.214-221
    • /
    • 2021
  • SiC MOSFETs require a faster and more reliable short-circuit protection circuit than conventional methods due to narrow short-circuit withstand times. Therefore, this research proposes a short-circuit protection circuit using a current-sensing circuit based on Rogowski coil. The method of designing the current-sensing circuit, which is a component of the proposed circuit, is presented first. The integrator and input/output filter that compose the current-sensing circuit are designed to have a wide bandwidth for accurately measuring short-circuit currents with high di/dt. The precision of the designed sensing circuit is verified on a double pulse test (DPT). In addition, the sensing accuracy according to the bandwidth of the filters and the number of turns of the Rogowski coil is analyzed. Next, the entire short-circuit protection circuit with the current-sensing circuit is designed in consideration of the fast short-circuit shutdown time. To verify the performance of this circuit, a short-circuit test is conducted for two cases of short-circuit conditions that can occur in the half-bridge structure. Finally, the short-circuit shutdown time is measured to confirm the suitability of the proposed protection circuit for the SiC MOSFET short-circuit protection.

The Homogeneity and Short-term Stability Test of Bio-matrix Reference Material for Total Mercury Analysis of Freshwater Fish (담수 어류 총수은 분석용 생물 표준물질 균질성, 안정성 시험평가)

  • Lee, Soo Yong;Lee, Jangho;Chung, David;Shim, Kyu-Young;Lee, Ha-Eun;Park, Ki-Wan
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.1033-1040
    • /
    • 2019
  • The National Environmental Specimen Bank (NESB) has set up a plan to develop reference materials in the facility for assuring analytical quality and validating analytical methods for its monitoring samples. Some of the crucial characteristics that reference materials must consist of are homogeneity and stability of both intra and inter-bottles. In this study, we examined the homogeneity and stability of cryogenically-milled muscle samples, from Common Carp (Cyprinus carpio) for total mercury. Homogeneity was tested using ANOVA analysis and regression analysis was used to test short-term stability. The variations of total mercury concentration did not significantly differ between the intra and the inter-bottle (F=0.8, p=0.37). Additionally, relative standard deviation of the total mercury concentration showed low values (2.28%). For the short-term stability test, total mercury variations were not statistically significant as demonstrated by the result of the regression analysis (F ratio = 3.11, p = 0.18). This suggests that the cryogenic-milling process has statistically proven the degree of homogeneity and short-term stability for samples of carp muscles in the chemical analysis for total mercury.

Study on the analysis of impulse test wave in the short coil (layer)of transformer winding (변압기 권선(층간)단락시의 충격파시험파형분석에 관한 연구)

  • 박민호
    • 전기의세계
    • /
    • v.25 no.5
    • /
    • pp.75-78
    • /
    • 1976
  • The most difficult problem encountered in impulse test of transformer is the determination of exact fauly for coil layer short. This paper is to establish one of improved standards in the above case by means of wave form analysis, based on the equivalent circuits and experimental investigation. During the fault occurs, the local oscillation in fault circuit is applicable where as the reflection wave is utilized to the main circuit. The result current wave form at neutral impeadance point is similar to the wave form by impulse test and has the singular wave form respectively.

  • PDF

The Intrinsic Safety Evaluation of Solar Photovoltaic Cell (태양전지셀의 본질안전 방폭성능 평가)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Si-Kuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.

Modification of Creep-Prediction Equation of Concrete utilizing Short-term Creep Test (단기 크리프 시험 결과를 이용한 콘크리트의 크리프 예측시의 수정)

  • 송영철;송하원;변근주
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.69-78
    • /
    • 2000
  • Creep of concrete is the most dominating factor affecting time-dependent deformations of concrete structures. Especially, creep deformation for design and construction in prestressed concrete structures should be predicted accurately because of its close relation with the loss in prestree of prestressed concrete structures. Existing creep-prediction models for special applications contain several impractical factors such as the lack ok accuracy, the requirement of long-term test and the lack of versatility for change in material properties, ets., which should be improved. In order to improve those drawbacks, a methodology to modify the creep-prediction equation specified in current Korean concrete structures design standard (KCI-99), which underestimates creep of concrete and does not consider change of condition in mixture design, is proposed. In this study, short-term creep tests were carried out for early-age concrete within 28 days after loading and their test results on influencing factors in the equation are analysed. Then, the prediction equation was modified by using the early-age creep test results. The modified prediction equation was verified by comparing their results with results obtained from long-term creep test.