• Title/Summary/Keyword: short length

Search Result 2,372, Processing Time 0.026 seconds

Prediction d Fatigue Growth Behavior of Short Cracks (짧은 균열의 피로성장거동예측)

  • 최용식;우흥식;한지원
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.47-53
    • /
    • 1993
  • The growth of short cracks can be well described in terms of the effective stress intensity factor range, which is calculated on the base of crack closure. The relation between the crack opening SIF and crack length is determined from the experimental results. The crack opening SIF of short cracks, Kop, can be predicted from the crack opening SIF at threshold of long crack, Kop.L. The growth rate of short cracks at notch root can be predicted from the crack opening SIF of short cracks, Kop, and the growth equation of long cracks in region II.

  • PDF

A Study of Spraying Curing Compound for Concrete Pavement Considering Environmental Condition in Tunnel (터널내 환경을 고려한 콘크리트 포장의 양생제 살포기준 연구)

  • Ryu, SungWoo;Kwon, OhSun;Song, GeoRuemSoo;Lee, MinKyung;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : This study is to suggest tunnel length to spray curing compound, based on the field tests. METHODS : At first field test, length from the entrance of tunnel to wet wall was checked by visual survey. The second and third test, various sensors were installed in concrete or in tunnel, such as RH sensor, temperature sensor, portable weather station and etc.. And also, test for bleeding and retaining water of concrete were conducted to evaluate environmental effect on concrete pavement. RESULTS : The result of the field experiment for tunnel length to spray curing compound indicates that length changes depending on tunnel length, season, and location. Environmental condition of a short tunnel was not much different between location near entrance and at center of tunnel. However, in case of a medium and long tunnel, effect of outside environmental condition decreased, when location moved into tunnel center of it. CONCLUSIONS : From the testing results, it can be proposed that optimum tunnel length to spray curing compound is 60m for a medium and long tunnel, and whole length for a short tunnel.

Analysis on Torso Somatotype of Adult Females by Tight Fitting Technique (입체재단에 의한 성인여성의 체간부 유형분석)

  • 홍정민
    • Journal of the Korean Society of Costume
    • /
    • v.42
    • /
    • pp.163-172
    • /
    • 1999
  • The purpose of this study is to classify the types of torso of adult females using the tight fitting technique and pattern development figure. The subjects are 106 females of 19 to 24 years old. 59 different items are measured from body surface development and analyzed by factor analysis and cluster analysis. The results are as follows; 1. Eight somatotype factors are obtained through factor analysis and orthogonal rotation by the method of Varimax Factor 1 is the length of upper body factor 2 the length of lower body factor 3 the circumference and width of the back of upper body factor 4 the circumference and width of front torso factor 5 the dart type of the back of upper body factor 6 the size of the back neck factor 7 the type of the front shoulder and factor 8 the size of the back arm hole. 2. As a result of cluster analysis the somatotype of torso is classified into 5 types. Type 1 is normal in length circumference and width of upper body. Type 2 is shortest length circumference and width of torso. Type 3 is long in length circumference and width of torso. Type 4 is normal length and short in circumference and width especially short in bust circumference. Type 5 is longest in length circumference and width of torso.

  • PDF

Yarn Hairiness Affecting Fluff Generation

  • Koo, Young-Seok
    • Fibers and Polymers
    • /
    • v.4 no.3
    • /
    • pp.119-123
    • /
    • 2003
  • Fluff (lint, fiber fly) generation, especially related to yarn structure, was investigated. Research centered on the fiber length related to fluff generation during the knitting process. Short fiber length composing yarn structure was a main source of the fluff shedding. High quality spun yarn with longer length of fiber was recommended to the high speed knitting industry in order to reduce process troubles such as yarn breakage, etc. but the cost is doubtable to the manufacturers. A trial to reduce the fluff trouble by using chemicals to hold the short fiber on the surface of the yam was suggested and the research showed a positive effect to the problem. However, another factors including a by-product of chemical residue and searching more feasible material need to be concerned for the future research.

STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS (상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석)

  • Kim, Han-Koo;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

Body Characteristics, Perceived Body Size and Body-Cathexis for Short Women Aged 18 to 59 (18~59세 키 작은 여성의 체형특징, 신체인식과 신체만족도 분석)

  • Lee, Jeong-Yim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.11
    • /
    • pp.1346-1361
    • /
    • 2011
  • This study examined the body characteristics, perceived body size and body-cathexis according to the stature of women aged 18 to 59. Special focus was on women of short stature; in addition, the study searched for the proper clothing fit and satisfaction level for short women. The 2010 SizeKorea data of 2,586 women aged 18 to 59 was analyzed statistically to find the distribution of stature according to 4 age groups along with the body characteristics and proportion of 3 stature groups in each age group. A questionnaire was conducted with responses from 412 women aged 18 to 59, and the perceived body size and satisfaction with body size of 3 stature groups were studied with 5 Likert scales. Although the stature of Korean women has increased, short stature women (those under 155cm) still represent a high percentage of individuals in Korea. Short women (small in height and length) had unique body characteristics in width, depth, and girth that were distinguished from the characteristics of medium or tall women. Especially, the lower body part of short women had distinct characteristics. Accordingly, it is undesirable to reflect the same ease or same body proportion in clothing construction for the 3 stature groups. Short women perceived their stature and length of upper or lower body as too short and the satisfaction with their body size was lower than medium or tall women. To upgrade the clothing fit and satisfaction of short women, it is necessary to reflect the unique body characteristics of short women in clothing design and construction.

The effect of growth hormone treatment on craniofacial growth in short stature children (저신장 소아에서 성장호르몬 치료가 두개안면골 성장에 미치는 영향)

  • Chung, Sung-Ho;Kim, Jin-Wook;Park, Yong-Hoon;Hwang, Chung-Ju;Lee, Hee-Kyung
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.227-238
    • /
    • 2010
  • Objective: The purpose of this study was to analyze the effect of growth hormone treatment (GHT) on craniofacial growth in children of short stature. Methods: Nineteen untreated children of short stature were referred from the Pediatric Department, Yeungnam University Hospital as a subject group. All subjects had lateral cephalograms taken before, after 1 year and after 2 years of growth hormone treatment. As a reference group, we selected 19 normal children with paired sampling who matched the subjects' age and sex, from the Department of Orthodontics, Kyungpook National University Hospital. Results: Before GHT, anterior cranial base length and upper posterior facial height, posterior total facial height, mandibular ramus length, and mandibular corpus length were significantly smaller in the reference group. In angular craniofacial measurements, saddle angle and mandibular plane angle were larger. SNA and SNB were smaller in the reference group. After two years of GHT, growth hormone accelerated growth in several craniofacial components. The posterior total facial height, the anterior, posterior cranial base length, and the mandibular ramus length were increased. And the difference in mandibular plane angle and ANB values compared with the reference group was decreased. Conclusions: GHT over 2 years leads to a craniofacial catch-up growth tendency, which is pronounced in interstitial cartilage and condylar cartilage.

Influence of Tunneling Current on Threshold voltage Shift by Channel Length for Asymmetric Double Gate MOSFET (비대칭 DGMOSFET에서 터널링 전류가 채널길이에 따른 문턱전압이동에 미치는 영향)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1311-1316
    • /
    • 2016
  • This paper analyzes the influence of tunneling current on threshold voltage shift by channel length of short channel asymmetric double gate(DG) MOSFET. Tunneling current significantly increases by decrease of channel length in the region of 10 nm below, and the secondary effects such as threshold voltage shift occurs. Threshold voltage shift due to tunneling current is not negligible even in case of asymmetric DGMOSFET to develop for reduction of short channel effects. Off current consists of thermionic and tunneling current, and the ratio of tunneling current is increasing with reduction of channel length. The WKB(Wentzel-Kramers-Brillouin) approximation is used to obtain tunneling current, and potential distribution in channel is hermeneutically derived. As a result, threshold voltage shift due to tunneling current is greatly occurred for decreasing of channel length in short channel asymmetric DGMOSFET. Threshold voltage is changing according to bottom gate voltages, but threshold voltage shifts is nearly constant.

Role of telomere length in subtelomeric gene expression and its possible relation to cellular senescence

  • Hernandez-Caballero, E.;Herrera-Gonzalez, N.E.;Salamanca-Gomez, F.;Arenas-Aranda, D.J.
    • BMB Reports
    • /
    • v.42 no.11
    • /
    • pp.747-751
    • /
    • 2009
  • Transcriptional silencing of subtelomeric genes is associated with telomere length, which is correlated with age. Long and short telomeres in young and old people, respectively, coincide with gene repression and activation in each case. In addition, differential location of genes with respect to telomeres causes telomere position effect. There is very little evidence of the manner in which age-related telomere length affects the expression of specific human subtelomeric genes. We analyzed the relationship between telomere length and gene expression levels in fibroblasts derived from human donors at ages ranging from 0-70 years. We studied three groups of genes located between 100 and 150 kb, 200 and 250 kb, and >300 kb away from telomeres. We found that the chromatin modifier-encoding genes Eu-HMTase1, ZMYND11, and RASA3 were overexpressed in adults. Our results suggest that short telomere length-related overexpression of chromatin modifiers could underlie transcriptional changes contributing to cellular senescence.

Analysis of Threshold Voltage Roll-off for Ratio of Channel Length and Thickness in DGMOSFET (DGMOSFET에서 채널길이와 두께 비에 따른 문턱전압변화분석)

  • Jung, Hak-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2305-2309
    • /
    • 2010
  • In this paper, the variations of threshold voltage characteristics for ratio of channel length and thickness have been alanyzed for DG(Double Gate)MOSFET having top gate and bottom gate. Since the DGMOSFET has two gates, it has advantages that contollability of gate for current is nearly twice and SCE(Short Channel Effects) shrinks in nano devices. The channel length and thickness in MOSFET determines device size and extensively influences on SCEs. The threshold voltage roll-off, one of the SCEs, is large with decreasing channel length. The threshold voltage roll-off and drain induced barrier lowing have been analyzed with various ratio of channel length and thickness for DGMOSFET in this study.