• 제목/요약/키워드: shim coil

검색결과 64건 처리시간 0.025초

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

소형 광디스크 드라이브용 선형 구동기의 설계 및 특성 해석 (Design and Analysis of a Linear Motor for Slim-line ODD)

  • 심민택;박준혁;백윤수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.794-798
    • /
    • 2002
  • This paper deals with a moving coil type linear motor for fast access of the miniature ODD. This slim-line motor is composed of the mover supported by guide mechanism, the coil wound into it, and the yoke attached to the permanent magnet for stator. The driving force is generated by the PM of the stator and the current in the coils of the mover. Magnetic circuit analysis and Finite Element Method are applied to estimate the thrust force at air gap. In order to compare the force characteristics between two methods, various experiment results are applied to verify on a prototype. Also the flexible modes of the motor are predicted through the FEM and the structural components are modified to locate this on high frequency region.

  • PDF

소형 ODD용 선형 구동기의 설계 및 특성 해석 (Design and Analysis of linear motor for slim-line ODD)

  • Shim, Min-Taek;Park, Joon-Hyuk;Baek, Yoon-Su
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.378.2-378
    • /
    • 2002
  • This paper deals with a moving coil type linear motor for fast access of the miniature ODD. This slim-line motor is composed of the mover supported by guide mechanism, the coil wound into it, and the yoke attached to the permanent magnet for stator. The driving force is generated by the PM of the stator and the current in the coil of the mover. Magnetic circuit analysis and Finite Element Method are applied to estimate force at air gap. (omitted)

  • PDF

Temperature-difference Flow Sensor Using Multiple Fiber Bragg Gratings

  • Kim, Kyunghwa;Eom, Jonghyun;Sohn, Kyungrak;Shim, Joonhwan
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.297-303
    • /
    • 2022
  • Multiple fiber Bragg gratings (FBGs) have been proposed and demonstrated for gas-flow measurements in a flow channel, using the temperature-difference method. This sensor consists of two FBG temperature sensors and two coil heaters. Coil heaters are used to heat the FBGs. The flow rate of the gas can be obtained by monitoring the difference in the Bragg-wavelength shifts of the two FBGs, which has features that exclude the effect of temperature fluctuations. In this study, experiments are conducted to measure the wavelength shift based on the flow rate, and to evaluate the gas-flow rate in a gas tube. Experimental results show that the sensor has a linear characteristic over a flow-rate range from 0 to 25 ℓ/min. The measured sensitivity of the sensor is 3.2 pm/(ℓ/min) at a coil current of 120 mA.

인삼박(人蔘粕) 및 인삼엽(人蔘葉)으로 제조(製造)한 Mosquito Coil Powder가 Rat 및 Mouse에 미치는 독성(毒性)에 관한 연구(硏究) (Toxicity Test of Mosquito Coil Powder Made of Ginseng Leaf and Ginseng Residue after Extraction with Ethanol- Water System)

  • 허재두;심순주;김용주;오정균;김재백
    • Journal of Pharmaceutical Investigation
    • /
    • 제9권3호
    • /
    • pp.22-26
    • /
    • 1979
  • This report was carried out toxicity test for the mosquito coil made of Ginseng leaf and the residue after extraction of Ginseng root. This results are as follows: In the first group, was not shown any special difference on the body weight, the motion and dissection. In the second group, was not shown any Special difference on the body weight, considerable difference on the motion and considerable loss of appetite besides very slight loss, but came cack soon again to normal state by change of air after a moment. In the third group, the body weight and appetite was depressed very slightly and the motion was shown very slightly difference, but came back soon again to normal state by chenge of air after a moment too. No one was died, and all the animal were the normal state on the reslt of dessection, Therefore, we have positive evidence that this mosquito coil powder is applied to animals without any toxicity.

  • PDF

Gas-Flow Sensor using Optical Fiber Bragg Grating(FBG)

  • Shim, Joon-Hwan;Cho, Seok-Je;Yu, Yung-Ho;Sohn, Kyung-Rak
    • 한국항해항만학회지
    • /
    • 제32권9호
    • /
    • pp.717-722
    • /
    • 2008
  • We have proposed and demonstrated an gas-flow sensor using optical fiber bragg grating(FEG). The flow sensor has no electronics and no mechanical parts in its sensing part and the structure is th11s simple and immune to electromagnetic interference(EMI). The FEG sensor was consisted qf the sensing element and a coil heater. The metal coil was used to supply the current to the FEG. While some currents supply to the coil, the refractive index of the FEG under the coil is changed and thus the wavelength shift of fiber optic sensor was induced In this work, the wavelength shift according to flow-rate was experimentally studied and was used to evaluate the gas flow-rate in a gas tube. As a result, it was possible to measure the flow-rate in a linear range from 5 to $20{\ell}/min$ with a resolution of approximately $1{\ell}/min$ at the applied currents of 100 mA and 120 mA. The measured sensitivities were $15.3\;pm/\ell/min$ for 100 mA and $20.2\;pm/\ell/min$ for 120 mA.

정상 압연 구간의 특징을 이용한 판 파단의 상태감시 (Condition Monitoring for Coil Break Using Features of Stationary Rolling Region)

  • 오준석;양승욱;심민찬;와휴 세사렌드라;양보석;이원호
    • 한국소음진동공학회논문집
    • /
    • 제19권12호
    • /
    • pp.1252-1259
    • /
    • 2009
  • Due to the international competition and global pressure, the roll speed is increased. However, higher speeds increase the power density in the process as well as the plant's potential to react with vibrations. Under certain operating conditions, vibrations may occur, which again cause chattermarks, strip rupture or coil break fault. The appropriate condition monitoring is needed to improve product quality and availability. The aim of condition monitoring is to reduce maintenance costs, increase productivity and improve product quality. This paper proposes a condition monitoring tool designed for the classification of coil break fault. This method is used to cold rolling mill for faults monitoring based on vibration and motor current signals. The results show that the performance of classification has high accuracy based on experimental work.

바코드 리더용 스캐닝 미러를 위한 무빙 코일 타입 VCM 설계 (Design of Electromagnetic Moving-coil type Voice Coil Motor for Scanning mirror of Barcode reader)

  • 신부현;이정우;심현호;박상구;이승엽
    • 대한기계학회논문집A
    • /
    • 제40권1호
    • /
    • pp.17-22
    • /
    • 2016
  • 바코드 리더를 위한 전자기력을 이용한 소형 회전 무빙 코일 타입 보이스 코일 구동기를 개발하였다. 본 구동기는 1 개의 자석과 1 개의 코일 그리고 1 개의 복원핀으로 이루어진 간단한 구조이다. 구동기는 DC 모터의 선형으로 근사화한 이론적인 모델링으로 해석하고, 유한 요소 해석 프로그램으로 모터 상수와 복원력 상수를 계산하여 동적 성능을 예측하였다. 공진 주파수는 64 Hz 이며 바코드 리더를 위한 50 Hz 의 주파수에서 60 deg 의 반사각을 가짐으로 예측되었다. 시작품을 제작하여 실험을 통하여 3 V 의 입력 전압에서 50 Hz 의 주파수에서 61.8 deg 의 반사각을 가짐을 확인하였다. 제안된 구동기는 Op-amp 를 이용하여 간단한 개루프 제어 회로 구성이 가능하다.

MRI 마그네트용 보정코일 설계 (Design of the Shimming Coils for MRI Magnet)

  • 배준한;고락길;진홍범;심기덕;권영길;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF

The safety and efficacy of double microcatheter technique in small and tiny ruptured aneurysms: A single center study

  • Hyeong Kyun Shim;Byung Jou Lee;Chae Heuck Lee;Moon Jun Sohn;Sook Young Shim;Chan Young Choi;Sung Rok Han;Kwang Hyeon Kim;Hae Won Koo
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제26권2호
    • /
    • pp.141-151
    • /
    • 2024
  • Objective: Double microcatheter technique (dMC) can be the alternative to Single microcatheter technique (sMC) for challenging cases, but there is lack of studies comparing dMC to sMC especifically for small ruptured aneurysms. Our objective was to compare the safety and efficacy of dMC to sMC in treating small (≤5 mm) and tiny (≤3 mm) ruptured aneurysms. Methods: This study focused on 91 out of 280 patients who had ruptured aneurysms and underwent either single or double microcatheter coil embolization. These patients were treated with either single or double microcatheter coil embolization. We divided the patients into two groups based on the procedural method and evaluated clinical features and outcomes. Subgroup analyses were conducted specifically for tiny aneurysms, comparing the two methods, and within the dMC group, we also examined whether the aneurysm was tiny or not. In addition, univariate logistic regression analysis was performed to assess the impact of coil packing density. Results: The mean values for most outcome measures in the dMC group were higher than those in the sMC group, but these differences did not reach statistical significance (coil packing density, 45.739% vs. 39.943%; procedural complication, 4.17% vs. 11.94%; recanalization, 8.3% vs. 10.45%; discharge discharge modified Rankin Scale (mRS), 1.83 vs. 1.97). The comparison between tiny aneurysms and other sizes within the dMC group did not reveal any significant differences in terms of worse outcomes or increased risk. The only factor that significantly influenced coil packing density in the univariate logistic regression analysis was the size of the aneurysm (OR 0.309, 95% CI 0.169-0.566, p=0.000). Conclusions: The dMC proved to be a safe and viable alternative to the sMC for treating small ruptured aneurysms in challenging cases.