• 제목/요약/키워드: shielding thickness

검색결과 266건 처리시간 0.041초

Novel Fabrication Process of Vertical Spring for Micro Mirror

  • Lim, Tae-Sun;Shin, jong-Woo;Kim, Yong-Kweon;Park, Bumkyoo
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.245-250
    • /
    • 1998
  • Novel fabrication process of vertical spring for micro mirror array is proposed. The proposed fabrication process adopts a shadow evaporation process using shielding screen structure on top of the sacrificial layer. The 50${\times}$50 micro mirror arrays are fabricated using the proposed process and ceramic packaged. The static and dynamic characteristics of mirror are measured. The mirror plate touches substrate at 16V and the response time of about 16.8 ${\mu}\textrm{s}$. The resonant frequency of mirror is 16kHz. The spring thickness is calculated from static characteristic to be 1075${\AA}$.

  • PDF

Validation of Some Protection Guidelines for Neighboring Pipelines against Fault Currents from Power Transmission Tower

  • Lee, Seong-Min;Song, Hong-Seok;Kim, Young Geun
    • Corrosion Science and Technology
    • /
    • 제6권2호
    • /
    • pp.77-81
    • /
    • 2007
  • Fault current can be discharged from power transmission tower due to lightning or inadvertent contact of crane, etc. Pipelines in proximity to either the source of the ground fault or the substation grounding grid may provide convenient conductive path for the fault current to travel. Inappropriate measures to the neighboring pipelines against the fault current may cause severe damages to the pipes such as coating breakdown, arc burn, puncture, loss in wall thickness, or brittle heat-affected zone. Like inductive and conductive AC coupling, steadily induced fault current right after the coating breakdown can lead to corrosion of the pipeline. In this work, some protection guidelines against fault currents used in the field have been validated through the simulation and analytical method.

방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증 (Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities)

  • 이기윤;정경환;한동희;김장오;한만석;길종원;백철하
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.489-495
    • /
    • 2023
  • 방사선 방어시설은 진단용 방사선 발생장치가 설치되어 있는 장소에 구축되어 환자, 방사선 작업 종사자 등의 피폭을 방지한다. 본 연구에서는 이러한 방사선 방어시설의 주 재료인 납에 대해 최대관전압별 차폐 두께의 경향성을 몬테칼로 시뮬레이션과 실측을 통해 비교 검증하고자 한다. 몬테칼로 시뮬레이션 코드 중 Monte Carlo N-Particle 6를 활용하였으며 해당 시뮬레이션 상에 모사한 납 차폐 구조도는 선원과 납 시트 사이의 거리는 100 cm, 조사야 크기는 10 × 10 cm2이며 관전압은 80, 100, 120, 140 kVp로 설정하였다. 각 관전압별 에너지 스펙트럼을 산출하여 시뮬레이션에 적용하였다. 80, 100, 120, 140 kVp별 각각 50, 70, 90, 95% 차폐율을 보이는 납 두께를 산출하였다. 80 kVp에서 각 차폐율에 해당하는 두께는 각각 0.03, 0.08, 0.2 1, 0.33 mm이며, 100 kVp에서는 0.05, 0.12, 0.30, 0.50 mm, 120 kVp에서는 0.06, 0.14, 0.38, 0.56 mm, 140 kV p에서는 0.08, 0.16, 0.42, 0.61 mm로 나타났다. 산출된 납 두께에 대해 실측을 진행하였으며 사용된 방사선 발생장치는 GE Healthcare 사의 Discovery XR 656이며 선량계측기의 경우 IBA 사의 MagicMax이다. 실측결과 80 kVp에서 각 두께별 차폐율은 43.56, 70.33, 89.85, 93.05%였으며 100 kVp에서는 52.49, 72.26, 86.31, 92.17%, 120 kVp에서는 48.26, 71.18, 87.30, 91.56%, 140 kVp에서는 50.45, 68.75, 89.95, 91.65%.로 나타났다. 시뮬레이션과 실측을 비교한 결과 두 값의 차이가 평균 약 3% 이내로 작은 것으로 확인되었다. 본 연구의 결과는 몬테칼로 시뮬레이션의 신뢰성을 검증함과 동시에 향후 방사선 방어시설의 구축에 있어 기초 데이터로 활용될 수 있을 것으로 사료된다.

PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가 (Evaluation of the Apron Effectiveness during Handling Radiopharmaceuticals in PET/CT Work Environment)

  • 조용인;예수영;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.237-244
    • /
    • 2015
  • 핵의학 종사자는 PET/CT 업무 환경 중 방사성 의약품 취급 시 상당히 높은 피폭선량을 받는다고 알려져 있으며, 이를 최소화하기 위해 적절한 차폐기구의 사용이 요구된다. 이에 본 연구에서는 몬테카를로 기법을 기반으로 한 모의실험과 실측을 통해 18F-FDG 선원 취급 시 Apron 착용에 대한 차폐효과에 대해 분석하였다. 그 결과, 모의실험의 경우 선원의 취급 위치에 따라 인체 장기별 선량 분포가 각각 다른 양상을 나타냈고, Apron 납 두께별 선량 감소율은 선원과 장기와의 위치가 근접할수록, 선원과의 접촉 거리가 멀수록 낮은 경향을 나타냈다. 선량 측정 장비를 통한 실측의 경우, 측정 장비간 특성으로 인해 평균 공간 선량률 분포는 상이한 결과를 보였으나, 거리별 납 당량의 증가에 따라 지수함수분포로 공간 선량률이 감소되었다.

New polyester composites synthesized with additions of different sized ZnO to study their shielding efficiency

  • M. Elsafi;M.I. Sayyed;Aljawhara H. Almuqrin
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2821-2827
    • /
    • 2024
  • This investigation developed a novel polyester composite based on the addition of zinc oxide (ZnO) of different sizes. We prepared nine samples Containing different percentages and sizes of ZnO as well as the control sample (Pol-ZnO0). The attenuation factors of Pol-micro ZnO were estimated using Phy-x software, while the HPGe detector and various gamma sources were used to experimentally measure the all-prepared composites. In terms of the two methods for micro composites, good agreement was observed. The linear attenuation coefficient (LAC) of Pol-ZnO20, Pol-ZnO40, and Pol-ZnO60, two more samples one with ZnO nanoparticles instead of microparticles, and the other with half microparticles and half nanoparticles (referenced as 0.5 M + 0.5 N) were determined. For all the Polyester composites and energies, the mixture of microparticles and nanoparticles had greater LAC values than each of the particles on their own. For example, the LAC values for the Pol-ZnO20 polymer at 1.330 MeV are 0.0836, 0.0888, and 0.0903 cm-1 for the microparticles, nanoparticles, and mixture, respectively. The values of the prepared polymer samples' radiation protection efficiency (RPE) against energy with a thickness of 2 cm was determined experimentally. The Pol-ZnO60 0.5 M + 0.5 N sample has the highest RPE out of all the samples, followed by its nanoparticle counterpart, and then its microparticle counterpart. On the other hand, the Pol-ZnO0 sample, the polymer with no ZnO content, at all energies has the lowest RPE, followed by the three Pol-ZnO20 samples.

디스플레이용 SiO2/ITO 투명전도막의 반사특성 (Reflection Properties of SiO2/ITO Transparent and Conductive Thin Films for Display)

  • 신용욱;김상우;윤기현
    • 한국세라믹학회지
    • /
    • 제39권3호
    • /
    • pp.233-239
    • /
    • 2002
  • CRT의 전면에 전자파차폐, 정전기 방지 및 저반사 효과를 위해 코팅되는 $SiO_2$/ITO (Indium Tin Oxide) 이층박막의 반사특성에 관하여 연구하였다. 실리카층 및 ITO층의 두께를 변화시키며 나타나는 반사율의 경향을 고찰하고, 이론적인 2층, 3층 저반사코팅의 디자인에 적용시켜 보았다. 입자 상으로 코팅된 ITO는 두께가 증가할수록 기공에 의해 박막의 불균일성이 증가하면서 이론적인 반사모델과의 차이가 커졌다. 실리카와 ITO의 계면에 존재하는 혼합층의 영향으로 인하여 실제측정반사율은 2층으로 디자인한 이론반사율보다 $SiO_2$/$SiO_2$+ITO/ITO의 3층으로 디자인한 반사모델에 보다 잘 적용되었다. 이론적인 저반사 디자인은 근거로 $SiO_2$/ITO 박막의 두께를 90, 65 nm로 조절한 이층막은 기준파장에서 2.5%의 반사율을 나타내었고, 가시광선 영역에서 이론반사율과 유사한 거동을 보였다.

Comparison of Characteristics of Gamma-Ray Imager Based on Coded Aperture by Varying the Thickness of the BGO Scintillator

  • Seoryeong Park;Mark D. Hammig;Manhee Jeong
    • Journal of Radiation Protection and Research
    • /
    • 제47권4호
    • /
    • pp.214-225
    • /
    • 2022
  • Background: The conventional cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)) scintillator-based gamma-ray imager has a bulky detector, which can lead to incorrect positioning of the gammaray source if the shielding against background radiation is not appropriately designed. In addition, portability is important in complex environments such as inside nuclear power plants, yet existing gamma-ray imager based on a tungsten mask tends to be weighty and therefore difficult to handle. Motivated by the need to develop a system that is not sensitive to background radiation and is portable, we changed the material of the scintillator and the coded aperture. Materials and Methods: The existing GAGG(Ce) was replaced with Bi4Ge3O12 (BGO), a scintillator with high gamma-ray detection efficiency but low energy resolution, and replaced the tungsten (W) used in the existing coded aperture with lead (Pb). Each BGO scintillator is pixelated with 144 elements (12 × 12), and each pixel has an area of 4 mm × 4 mm and the scintillator thickness ranges from 5 to 20 mm (5, 10, and 20 mm). A coded aperture consisting of Pb with a thickness of 20 mm was applied to the BGO scintillators of all thicknesses. Results and Discussion: Spectroscopic characterization, imaging performance, and image quality evaluation revealed the 10 mm-thick BGO scintillators enabled the portable gamma-ray imager to deliver optimal performance. Although its performance is slightly inferior to that of existing GAGG(Ce)-based gamma-ray imager, the results confirmed that the manufacturing cost and the system's overall weight can be reduced. Conclusion: Despite the spectral characteristics, imaging system performance, and image quality is slightly lower than that of GAGG(Ce), the results show that BGO scintillators are preferable for gamma-ray imaging systems in terms of cost and ease of deployment, and the proposed design is well worth applying to systems intended for use in areas that do not require high precision.

철근 콘크리트에 의한 전자기파 차폐 효과 모델링 (Electromagnetic Modeling of Shielding Effectiveness of Reinforced Concrete Walls)

  • 현세영;이경원;김민석;육종관
    • 한국전자파학회논문지
    • /
    • 제23권3호
    • /
    • pp.384-391
    • /
    • 2012
  • 본 논문은 철근 콘크리트에 대한 전자기적 모델링을 하고, 전파에 대한 차폐 효과를 분석하였다. 철근 콘크리트는 대부분의 건축물에 쓰이고 있으며, 내부에 격자 구조의 철근을 설치하기 때문에 특정 주파수 대역에서 전파의 차폐 효과가 있다. 철근 콘크리트의 해석은 3D EM(3-dimensional electromagnetic) 시뮬레이션 툴을 이용하여 철근과 콘크리트를 각각 해석한 뒤 그 영향을 고려하여 전체 철근 콘크리트의 해석을 하였다. 콘크리트의 경우 주파수가 높아짐에 따라 손실 특성 역시 높아져 차폐 효과가 커진다. 단층 철근의 경우 철근의 두께가 두꺼워질수록 차폐 효과가 커지며 주파수가 낮을수록 철근에 의한 차폐 효과가 커지는 것을 분석하였다. 또한, 철근과 철근 사이의 간격이 넓어질수록 차폐 효과가 낮아진다. 철근 구조를 2층으로 확장한 경우에 대해서도 철근과 철근 층 사이의 거리에 따른 차폐 효과에 대한 분석을 하였다. 철근 콘크리트 단층 철근을 사용한 경우, 철근두께 가 10, 20, 30 mm일 때 500 MHz에서 각각 철근 콘크리트 두께 10 cm당 -1.89, -2.73, -4.76 dB/10 cm의 투과 특성 값을 가지며, 두 층 철근을 이용한 경우에도 철근 두께에 대하여 -2.46, -6.16, -9.55 dB/10 cm의 투과 특성을 나타낸다.

저성능 자기차폐실에서 64채널 DROS 2차 미분계 시스템의 잡음 특성 (Noise Characteristics of 64-channel 2nd-order DROS Gradiometer System inside a Poorly Magnetically-shielded Room)

  • 김진목;이용호;유권규;김기웅;권혁찬;박용기
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.33-39
    • /
    • 2006
  • We have developed a second-order double relaxation oscillation SQUID(DROS) gradiometer with a baseline of 35 mm, and constructed a poorly magnetically-shielded room(MSR) with an aluminum layer and permalloy layers for magnetocardiography(MCG). The 2nd-order DROS gradiometer has a noise level of 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz inside the heavily-shielded MSR with a shielding factor of $10^3$ at 1 Hz and $10^4-10^5$ at 100 Hz. The poorly-shielded MSR, built of a 12-mm-thick aluminum layer and 4-6 permalloy layers of 0.35 mm thickness, is 2.4mx2.4mx2.4m in size, and has a shielding factor of 40 at 1 Hz, $10^4$ at 100 Hz. Our 64-channel second-order gradiometer MCG system consists of 64 2nd-order DROS gradiometers, flux-locked loop electronics, and analog signal processors. With the 2nd-order DROS gradiometers and flux-locked loop electronics installed inside the poorly-shielded MSR, and with the analog signal processor installed outside it, the noise level was measured to be 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz on the average even though the MSR door is open. This result leads to a low noise level, low enough to obtain a human MCG at the same level as that measured in the heavily-shielded MSR. However, filters or active shielding is needed fur clear MCG when there is large low-frequency noise from heavy air conditioning or large ac power consumption near the poorly-shielded MSR.

  • PDF

치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과 (Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography)

  • 이태희;정승훈;김동우;박명환;김태형
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.459-464
    • /
    • 2019
  • 치과 콘빔 전산화단층 검사 시 갑상선 부위의 방사선 피폭선량을 최소화하기 위하여 보루스 (Bolus)를 이용한 차폐체를 제작하고, 방사선 차폐 효과와 영상의 적정성을 평가하였다. 치과용 콘빔 전산화단층검사장비를 사용하여 치과방사선 두부 팬텀을 대상으로 갑상선의 좌, 우측 부위에 유리선량계를 부착시켜 방사선량을 측정하였다. 차폐체의 두께를 각각 10 mm, 20 mm, 30 mm로 다르게 하여 각 차폐체별로 흡수선량을 측정하여 차폐체를 사용하지 않았을 경우와 비교하였다. 8명의 평가자가 진료영상의 적정성을 여부를 평가하였다. 왼쪽 갑상선 부위에 30 mm Bolus 차폐체를 사용한 경우에는 결과값이 평균 $342.67{\mu}Gy$로 Bolus 차폐체를 사용하지 않고 측정한 결과값의 평균 $431.22{\mu}Gy$보다 20.7% 감소하였고, 오른쪽 갑상선 부위에 30 mm Bolus 차폐체를 사용한 경우에는 평균 $424.56{\mu}Gy$로 21.9%의 선량감소효과를 보였다. 진료 영상의 적정성은 평가자 모두 사용 가능하다 판단하였다. 결론적으로, 치과 콘빔 전산화단층검사 시 갑상선 부위의 방사선 피폭선량을 최소화하기 위해 제작된 Bolus 차폐체는 장해음영 없이 적정한 진단 영상 처리가 가능하고, 방사선차폐 효과가 있어 유용한 차폐체로 적용 가능할 것으로 사료된다.