• Title/Summary/Keyword: shielding materials

Search Result 553, Processing Time 0.023 seconds

The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials (방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定))

  • Huh, Joon;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

A Study on the Electromagnetic Shielding Characteristics of Crash Pad Using Electrically Conductive Powders and Al-coated Glass Fiber as Filler in Automotive (전기전도성 분말과 알루미늄 코팅 유리섬유를 사용한 자동차용 크래쉬패드의 전자파 차폐 특성에 관한 연구)

  • Cho, Hong;Jeoung, Sun-Kyoung;Kim, Byeong-Woo
    • Journal of Powder Materials
    • /
    • v.21 no.2
    • /
    • pp.124-130
    • /
    • 2014
  • The automotive industry is moving from the internal combustion engine to electric drive motors. Electric motors uses a high voltage system requiring the development of resources and components to shield the system. Therefore, in this study, we analyze electromagnetic interference (EMI) shielding effectiveness (SE) characteristics of an auto crash pad according to the ratio of electrically conductive materials and propylene. In order to combine good mechanical characteristics and electromagnetic shielding of the automotive crash pad, metal-coated glass fiber (MGF) manufacturing methods are introduced and compared with powder-type methods. Through this study, among MGF methods, we suggest that the chopping method is the most effective shielding method.

Effect of Heat Treatment on Radiation Shielding Properties of Concretes

  • Singh, Vishwanath P.;Tekin, Huseyin O.;Badiger, Nagappa M.;Manici, Tubga;Altunsoy, Elif E.
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • Background: Heat energy produced in nuclear reactors and nuclear fuel cycle facilities interactions modifies the physical properties of the shielding materials containing water content. Therefore, in the present paper, effect of the heat on shielding effectiveness of the concretes is investigated for gamma and neutron. The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors. Materials and Methods: The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors of ordinary and heavy concretes were investigated using NIST data of XCOM program and Geometric Progression method. Results and Discussion: The improvement in shielding effectiveness for photon and reduction in fast neutron for ordinary concrete was observed. The change in the neutron shielding effectiveness was insignificant. Conclusion: The present investigation on interaction of gamma and neutron radiation would be very useful for assessment of shielding efficiency of the concrete used in high temperature applications such as reactors.

Effect of different tungsten compound reinforcements on the electromagnetic radiation shielding properties of neopentyl glycol polyester

  • Can, Omer;Belgin, Ezgi Eren;Aycik, Gul Asiye
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1642-1651
    • /
    • 2021
  • In this study, isophtalic neopentyl glycol polyester (NPG-PES) based composites with different loading ratios of pure tungsten metal (W), tungsten (VI) oxide (WO3), tungsten boron (WB) and tungsten carbide (WC) composites were prepared as alternative shielding materials for ionizing electromagnetic radiation (IEMR) shielding. Structural characterizations of the composites were done. Gamma spectrometric analysis of composites for 80-2000 keV energy range was performed and their usability as IEMR shielding was discussed. As a result, the produced composites showed a shielding performance of 60-100% of the lead (the most widely used IEMR shielding material) depending on the reinforcement material, reinforcement loading rate and experimental conditions. Thus, it was reported that produced composites could be an alternative to lead shieldings that have several disadvantages as toxic properties, difficulty of processing and inelasticity.

Study on Effective Shielding of Secondary Radiation Generated by High Energy Proton Accelerator (고 에너지 양성자 가속기에서 생성되는 2차 방사선의 효과적인 차폐에 관한 연구)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.383-388
    • /
    • 2020
  • High-energy proton accelerators continue to be increasingly used in medical, research and industrial settings. However, due to the high energy of protons, a large number of secondary radiation occurs. Among them, neutrons are accompanied by difficulties of shielding due to various energy distribution and permeability. So In this study, we propose a shielding method that can shield neutrons most efficiently by using multiple-shielding material used as a decelerating agent or absorbent as well as a single concrete shielding. The flux of secondary neutrons showed a greater decrease in the flux rate when heavy concrete was used than in the case of ordinary concrete, and the maximum flux reduction was observed at the front position when using multiple shields. Multiple shielding can increase shielding efficiency more than single shielding however, As the thickness of the multiple shielding materials increased, the decline in flux was saturated. The mixture material showed higher shielding results than the polyethylene when using boron carbonate.

Establishment of the Electromagnetic Shielding Effectiveness Measurement System (전자파차폐효과 측정시스템의 구현)

  • 정연춘;강태원;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.3
    • /
    • pp.45-53
    • /
    • 1993
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power to that which passes through the material under test. The measurement system is constructed using several test fixtures, tracking generator, spectrum analyzer, step attenuator, RF switches, and amplifiers, etc.. The automation of measurements is completed using a personal computer. Especially, incident power, reflected power, and transmitted power are measured with only one spectrum analyzer using a dual directional coupler and RF switches. Therefore the system is to be used in design of shielding materials, as well as shielding effectiveness measurements. This system has dynamic range of more than 120 dB in the frequency range of 10 MHz to 1 GHz, and it can be used to measure shielding effectiveness of composite materials.

  • PDF

Impacts of the calcination temperature on the structural and radiation shielding properties of the NASICON compound synthesized from zircon minerals

  • Islam G. Alhindawy;Hany Gamal;Aljawhara.H. Almuqrin;M.I. Sayyed;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1885-1891
    • /
    • 2023
  • The present work aims to fabricate Na1+xZr2SixP3-xO12 compound at various calcination temperatures based on the zircon mineral. The fabricated compound was calcinated at 250, 500, and 1000℃. The effect of calcination temperature on the structure, crystal phase, and radiation shielding properties was studied for the fabricated compound. The X-ray diffraction diffractometer demonstrates that, the monoclinic crystal phase appeared at a calcination temperature of 250℃ and 500℃ is totally transformed to a high-symmetry hexagonal crystal phase under a calcination temperature of 1000℃. The radiation shielding capacity was also qualified for the fabricated compounds using the Monte Carlo N-Particle transport code in the g-photons energy interval between 15keV and 122keV. The impacts of calcination temperature on the g-ray shielding behavior were clarified in the present study, where the linear attenuation coefficient was enhanced by 218% at energy of 122keV, when the calcination temperature increased from 250 to 1000℃, respectively.

Verification of Shielding Materials for Customized Block on Metal 3D Printing (금속 3D 프린팅을 통한 맞춤형 차폐블록 제작에 사용되는 차폐 재료 검증)

  • Kyung-Hwan, Jung;Dong-Hee, Han;Jang-Oh, Kim;Hyun-Joon, Choi;Cheol-Ha, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • As 3D printing technology is used in the medical field, interest in metal materials is increasing. The Department of Radiation Oncology uses a shielding block to shield the patient's normal tissue from unnecessary exposure during electron beam therapy. However, problems such as handling of heavy metal materials such as lead and cadmium, reproducibility according to skill level and uncertainty of arrangement have been reported. In this study, candidate materials that can be used for metal 3D printing are selected, and the physical properties and radiation dose of each material are analyzed to develop a customized shielding block that can be used in electron beam therapy. As candidate materials, aluminum alloy (d = 2.68 g/cm3), titanium alloy (d = 4.42 g/cm3), and cobalt chromium alloy (d = 8.3 g/cm3) were selected. The thickness of the 95% shielding rate point was derived using the Monte Carlo Simulation with the irradiation surface and 6, 9, 12, and 16 energies. As a result of the simulation, among the metal 3D printing materials, cobalt chromium alloy (d = 8.3 g/cm3) was similar to the existing shielding block (d = 9.4 g/cm3) in shielding thickness for each energy. In a follow-on study, it is necessary to evaluate the usefulness in clinical practice using customized shielding blocks made by metal 3D printing and to verify experiments through various radiation treatment plan conditions.

A Study on the Electromagnetic Shielding of Conductive Powder (도전성(導電性) 분체(粉體)의 전자차폐(電磁遮蔽)에 관한 연구(硏究))

  • Kim, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.244-249
    • /
    • 2004
  • In this paper, shielding effectiveness(SE) of the shielding paint of electromagnetic(EM) waves was investigated with actual experiments. The shielding paint used in this study were made of powder of conductive materials - Ag, Cu, Al, Sn, Ni. Cr, Graphite and Charcoal etc. with a solubility in oil and water. Also, the paper was used as a base sheet. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that silver, copper, nickel were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of density of particles on the SE were studied about the EM shielding paint. The SE strongly depended on the electric resistance by density of painting particles. SE increased as the density of particles was increasing.

  • PDF

Development of Heat Absorbing and High Electromagnetic Shielding Pre-Painted Steel Sheet

  • Hosokawa, Tomoaki;Ueda, Kohei;Yuasa, Kensei;Nakazawa, Makoto
    • Corrosion Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.153-158
    • /
    • 2010
  • Electrical appliances such as audiovisual equipment and personal computers have recently had heat and electromagnetic problems. In order to solve those problems, 'High heat absorbing pre-painted steel sheet (hereinafter referred to as PSS)', 'High electromagnetic shielding PSS' and 'High heat absorbing and high electromagnetic shielding PSS' have been developed. In this paper, the heat characteristics and electromagnetic shielding properties of PSS are investigated by methods that use enclosures and their mechanisms are discussed. It was found that 'High heat absorbing PSS' and 'High heat absorbing and high electromagnetic shielding PSS'could reduce the heat problem. The mechanism of the heat characteristics was presumed for the high heat absorptivity of the back coating inside the enclosure. And it was also found that 'High electromagnetic shielding PSS' and 'High heat absorbing and high electromagnetic shielding PSS' could shield electromagnetic waves well. The mechanism of the electromagnetic shielding properties was considered for the low transfer impedance of the back coating inside the enclosure. 'High heat absorbing PSS' and 'High electromagnetic shielding PSS' have been adopted as materials for electrical appliances and 'High electromagnetic shielding and high heat absorbing PSS' have been tested for that purpose.