• 제목/요약/키워드: shear stud

검색결과 197건 처리시간 0.018초

Load-slip curves of shear connection in composite structures: prediction based on ANNs

  • Guo, Kai;Yang, Guotao
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.493-506
    • /
    • 2020
  • The load-slip relationship of the shear connection is an important parameter in design and analysis of composite structures. In this paper, a load-slip curve prediction method of the shear connection based on the artificial neural networks (ANNs) is proposed. The factors which are significantly related to the structural and deformation performance of the connection are selected, and the shear stiffness of shear connections and the transverse coordinate slip value of the load-slip curve are taken as the input parameters of the network. Load values corresponding to the slip values are used as the output parameter. A twolayer hidden layer network with 15 nodes and 10 nodes is designed. The test data of two different forms of shear connections, the stud shear connection and the perforated shear connection with flange heads, are collected from the previous literatures, and the data of six specimens are selected as the two prediction data sets, while the data of other specimens are used to train the neural networks. Two trained networks are used to predict the load-slip curves of their corresponding prediction data sets, and the ratio method is used to study the proximity between the prediction loads and the test loads. Results show that the load-slip curves predicted by the networks agree well with the test curves.

CFT 구조에 적용된 스터드 전단연결재의 파괴 거동에 대한 실험 및 해석적 연구 (Experimental and Analytical studies on Failure Behavior of Stud Shear Connectors in CFT Structures)

  • Lee, Sangyoon
    • 한국재난정보학회 논문집
    • /
    • 제9권4호
    • /
    • pp.400-412
    • /
    • 2013
  • CFT 구조는 내부의 콘크리트와 강관의 합성거동을 위한 전단연결재를 필요로 한다. 하지만, 현행 설계기준에서는 통상적으로 무근콘크리트로 채워지는 CFT 구조에 적용할 수 있는 전단연결재에 대한 설계기준을 제시하고 있지 않다. 본 연구는 강-콘크리트 합성구조에 널리 사용되는 스터드 전단연결재를 CFT 구조에 적용하기 위한 설계기준 즉, CFT 구조에 적용된 스터드 전단연결재의 전단강도를 제안하기 위한 연구의 일환으로 수행되었다. 본 연구에서는 CFT 구조에 적용된 스터드의 전단강도를 결정하는 주된 파괴모드를 검토하기 위하여 무근콘크리트를 적용한 직접전단실험체를 이용하여 실험을 수행하고 파괴모드를 분석하기 위한 유한요소해석을 실시하였다. 직접전단실험 및 유한요소해석결과로부터 CFT 구조에 적용된 스터드 전단연결재의 주된 파괴모드는 콘크리트의 쪼갬파괴이며, 이러한 파괴모드로 인하여 철근콘크리트에 적용된 스터드에 비해 전단강도가 감소한다는 사실을 확인할 수 있었다.

이중합성 교량의 복합스터드 전단연결부의 정적강도 평가 (Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges)

  • 김현호;심창수;윤광중;이필구
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.549-559
    • /
    • 2005
  • 철도교는 강성이 주요한 설계인자이기 때문에 기존의 2거더 교량의 구조적 효율성을 높이기 위해서 이중합성 구조를 가진 철도교를 제안하였다. 일반적으로 강합성 연속교를 설계할 경우, 부모멘트 구간에 존재하는 콘크리트 바닥판은 인장에 저항하지 못한다고 가정하고 바닥판 단면을 무시하게 된다. 부모멘트 구간에서는 합성단면의 강성이 감소하게 되므로 이를 보완하기 위해 강재단면이 커지게 되는데, 이러할 경우 변단면의 적용이 불가피하게 되고 강합성형으로서의 장점이 반감된다고 할 수 있다. 이와 같은 문제점을 해결하기 위한 다양한 접근법이 존재하지만 그 중에서도 경간을 확대하고 강성이 중요한 설계인자가 되는 경우에 적절하게 사용될 수 있도록 제안된 교량의 형태가 이중합성구조이다. 따라서 본 연구에서는 이중합성 전단연결부의 거동을 파악하기 위하여 수평스터드, 수평스터드와 수직스터드가 함께 배치된 복합스터드 부재에 대한 push-out 실험을 수행하였다. 실험결과의 분석을 통하여 기존의 설계식과의 비교를 수행하고 정적 거동을 평가하였다.

경량기포모르터와 합성한 경량형강 벽체의 전단 저항 (Shear Resistance of Light-gauge Steel Stud Wall infilled with light-weight foamed mortar)

  • 이상섭;배규웅
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.397-406
    • /
    • 2004
  • 본 논문은 경량형강으로 제작한 프레임에 경량기포모르터를 채운 경량합성벽체의 전단 거동에 대한 실험 결과와 전단 강도 및 강성 평가를 제시한 것이다. 경량기포모르터는 스틸하우스 벽체의 구조 성능 및 단열 성능의 향상과 마감에 대한 시공성 개선을 위해 도입되었다. 연구 결과 단열 성능에 대한 기여도는 낮으나, 경량기포모르터의 슬러리 비중이 0.8 이상인 경우 구조 성능의 향상과 마감성이 좋은 것으로 나타났다. 본 연구에서는 전단 거동에 미치는 경량기포모르터의 영향을 알아보기 위해 경량기포모르터의 비중(0.6, 0.8, 1.0, 1.2) 벽체의 스터드 배치간격(450mm, 600mm, 900mm), 마감재(경량기포모르터, OSB, 석고보드) 및 브레이싱 등을 변수로 한 14개의 경량합성벽체를 제작하였고 비교를 위해 대표적인 스틸하우스 벽체 3개를 제작하였다. 면내전단 실험결과, 경량기포모르터를 타설한 경량합성벽체가 기존의 스틸스터드 벽체에 비해 최대 내력은 1.15~5.38배, 초기강성은 1.45~13.7배 증가한 것으로 나타났다. 또한 벽체 내부의 스터드를 900mm까지 확장하여도 무리가 없는 것으로 나타났다. 그러나 이와 같은 결과는 건조수축 균열이 억제되지 않은 상태에서 나온 것으로 경량합성벽체의 내력을 향상시키기 위해서는 경량기포모르터의 초기 건조수축균열을 억제하고 스터드와 경량기포모르터 사이의 부착력을 확보하는 것이 무엇보다도 중요한 것으로 나타났다.

프리캐스트 바닥판 합성형 교량에서의 베딩층의 두께를 고려한 전단연결재의 피로강도 (Fatigue strength of stud shear connector considering bedding layer thickness in precast deck composite bridges)

  • 류형근;심창수;정철헌;장승필
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.113-120
    • /
    • 2002
  • 프리캐스트 바닥판 합성형 교량의 전단연결부는 전단포켓과 베딩층이 존재하여 현장타설 강합성 교량과는 다른 구조적 특징을 갖고 있다. 따라서 프리캐스트 바닥판의 전단연결재 설계의 기초를 수립하기 위해서는 실험을 통한 연구가 수행되어야 한다. 프리캐스트 바닥판 합성형 교량의 전단연결재의 피로수명을 평가하기 위하여 베딩층의 두께를 변수로 한 전단연결재의 push-out 피로 시험을 수행하였다. push-out 피로 시험의 수행 결과, 전단연결재의 파괴모드를 확인하였고, 이를 통해 프리캐스트 바닥판 합성형 교량의 전단연결재의 피로수명 곡선식을 유도하였다.

Study on flexural capacity of simply supported steel-concrete composite beam

  • Liu, Jing;Ding, Fa-xing;Liu, Xue-mei;Yu, Zhi-wu
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.829-847
    • /
    • 2016
  • This paper investigates the flexural capacity of simply supported steel-concrete composite I beam and box beam under positive bending moment through combined experimental and finite element (FE) modeling. 24 composite beams are included into the experiments and parameters including shear connection degree, transverse reinforcement ratio, section form of girder, diameter of stud and loading way are also considered and investigated. ABAQUS is employed to establish FE models to simulate the behavior of composite beams. The influences of a few key parameters, such as the shear connection degree, stud arrangement, stud diameter, beam length and loading way, on flexural capacity are discussed. In addition, three methods including GB standard, Eurocode 4, and Nie method are also used to estimate the flexural capacity of composite beams and also for comparison with experimental and numerical results. The results indicate that Nie method may provide a better estimation in comparison to other two standards.

Nonlinear numerical model of headed shear stud anchors for composite open web steel joists

  • Yanez, Sergio J.;Dinehart, David W.;Pina, Juan Carlos;Guzman, Carlos Felipe
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.545-555
    • /
    • 2022
  • Empirical relationships that capture the nonlinear behavior of headed steel shear stud anchors have been derived from standard push out tests, where the specimens are comprised of large wide flanged steel sections attached to flat concrete slabs via the anchors. However, many composite systems used in practice utilize much smaller steel members and/or steel decking as part of the slab system. Composite open web steel joist systems generally include both of these elements and consequently the nonlinear performance ofthe anchor is not accurately represented by existing models. In this paper, a new empirical relation is presented for open web steel joist systems based on experimental results from a modified push out test that more realistically represent a composite open web steel joist system. The methodology for obtaining the proposed nonlinear function where the response of the system is characterized by two parameters(α and β) is presented. The two-step process for obtaining the two parameters is described and the empirical relation is calibrated with the experimental data. In comparison with existing expressions, the new proposal herein more accurately predicts the high initialstiffness of the system and overall nonlinear system performance.

Mechanical behavior of prefabricated steel-concrete composite beams considering the clustering degree of studs

  • Gao, Yanmei;Fan, Liang;Yang, Weipeng;Shi, Lu;Zhou, Dan;Wang, Ming
    • Steel and Composite Structures
    • /
    • 제45권3호
    • /
    • pp.425-436
    • /
    • 2022
  • The mechanical behaviors of the prefabricated steel-concrete composite beams are usually affected by the strength and the number of shear studs. Furthermore, the discrete degree of the arrangement for shear stud clusters, being defined as the clustering degree of shear stud λ in this paper, is an important factor for the mechanical properties of composite beams, even if the shear connection degree is unchanged. This paper uses an experimental and calculation method to investigate the influence of λ on the mechanical behavior of the composite beam. Five specimens (with different λ but having the same shear connection degree) of prefabricated composite beams are designed to study the ultimate supporting capacity, deformation, slip and shearing stiffness of composite beams. Experimental results are compared with the conventional slip calculation method (based on the influence of λ) of prefabricated composite beams. The results showed that the stiffness in the elastoplastic stage is reduced when λ is greater than 0.333, while the supporting capacity of beams has little affected by the change in λ. The slip distribution along the beam length tends to be zig-zagged due to the clustering of studs, and the slip difference increases with the increase of λ.

Behavior of optimized prestressed concrete composite box-girders with corrugated steel webs

  • Lu, Yanqiu;Ji, Lun
    • Steel and Composite Structures
    • /
    • 제26권2호
    • /
    • pp.183-196
    • /
    • 2018
  • The traditional prestressed concrete composite box-girders with corrugated steel webs have several drawbacks such as large deflection and potential local buckling. In this study, two methods were investigated to optimize and improve the prestressed concrete composite box-girders with corrugated steel webs. The first method was to replace the concrete bottom slab with a steel plate and the second method was to support the concrete bottom slab on the steel flanges. The behavior of the prestressed concrete composite box-girders with corrugated steel webs with either method was studied by experiments on three specimens. The test results showed that behavior of the optimized and upgraded prestressed concrete composite box-girders with corrugated steel webs, including ultimate bearing capacity, flexural stiffness, and crack resistance, is greatly improved. In addition, the influence of different shear connectors, including perfobond leisten (PBL) and stud shear connectors, on the behavior of prestressed concrete composite box-girders with corrugated steel webs was studied. The results showed that PBL shear connectors can greatly improve the ultimate bearing capacity, flexural stiffness and crack resistance property of the prestressed concrete composite box-girders with corrugated steel webs. However, for the efficiency of prestressing introduced into the girder, the PBL shear connectors do not perform as well as the stud shear connectors.

강합성 교량 스터드 전단연결재의 피로 설계식 평가 및 제안 (Assessment and Recommendation of Fatigue Design Codes for Stud Shear Connectors in Composite Bridge)

  • 이경찬;윤기용
    • 한국방재학회 논문집
    • /
    • 제9권5호
    • /
    • pp.15-21
    • /
    • 2009
  • AASHTO LRFD 설계 기준에 따른 합성형 교량 전단연결재 설계는 주로 강도보다는 피로에 의해 지배되는 것으로 알려져 있다. 이 피로 설계는 1966년 Slutter와 Fisher의 연구에 근거하고 있다. 당시의 시험은 1면으로 수행되었기 때문에 편심이 작용하였고, 이로 인하여 전단연결재에 별도의 인장력이 가해지게 되어 피로 강도가 감소되는 결과를 낳은 것으로 보인다. 또한, 피로 S-N 곡선은 응력변동폭과 하중반복 횟수 각각의 로그 스케일에 대하여 선형 관계를 보이는 것으로 Fisher에 의해 후에 밝혀졌으나, 전단연결재의 경우에 대해서만은 아직도 응력변동폭에 로그를 취하지 않고 있다. 이 연구는 현재 미국, 영국, 유럽, 일본에서 사용 중인 피로 설계 곡선을 비교 검토한 결과 미국 설계 기준이 비교적 보수적인 설계를 하고 있음을 확인하였다. 나아가, 당시의 실험 세팅과 데이터를 재분석하고 최근까지 전 세계에 공개된 피로 실험 데이터를 수집하여 분석 비교하고, 이를 바탕으로 적절한 설계식을 추천하고자 한다.