• Title/Summary/Keyword: shear structure

Search Result 2,353, Processing Time 0.043 seconds

A Study on the Block Shear Strength according to the Layer Composition of and Adhesive Type of Ply-Lam CLT (Ply-Lam CLT의 층재 구성 및 접착제 종류에 따른 블록전단강도에 관한 연구)

  • CHOI, Gyu Woong;YANG, Seung Min;LEE, Hyun Jae;KIM, Jun Ho;CHOI, Kwang Hyeon;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.791-806
    • /
    • 2020
  • In this study, a block shear strength test was conducted to compare and analyze the strength and failure mode on the glued laminated timber, CLT, and Ply-lam CLT, which are mainly used for the construction of wood construction as engineering wood. Through this, the Ply-lam CLT manufacturing conditions for optimum production, such as the type of lamina, plywood, adhesive, and layer composition, were investigated. The results are as follow. Through block shear strength test, it showed high strength in the order of glued laminated timber, Ply-lam CLT and CLT. In particular, the shear strength of Ply-lam CLT, which is made of a composite structure of larch plywood and larch lamina, passed 7.1 N/㎟, which is a Korean industrial standards for block shear strength of structural glued laminated timber. In addition, in this study, there was no different in shear strength according to the adhesive type used for glulam, CLT, and Ply-lam CLT adhesion. However, in the case of Ply-lam CLT, the difference in shear strength of Ply-lam CLT was shown according to the type of lamina and plywood. The results showed high strength in the order of Larix kaempferi > Mixed light hardwood ≒ Pinus densiflora, sieb, et, Zucc plywood. The optimal configuration of Ply-lam CLT is when larch plywood and larch lamina are used, and it is decided that the adhesive can be used by selecting PRF and PUR according to the application. The results of block shear strength failure mode by type of wood based materials were analyzed. The failure mode showed shear parallel-to-grain for glulam, rolling shear for CLT, and shear parallel-to-grain and rolling for ply-lam CLT. This is closely related to shear strength results and is decided to indicate higher shear strength in Ply-lam CLT than in CLT due to rolling shear.

Effects on Bond Strength between Zirconia and Porcelain according to Etching Treatment and Low Temperature Degradation (지르코니아 표면에칭처리와 저온열화현상이 지르코니아와 전장도재의 결합강도에 미치는 영향)

  • Park, Jin-Young;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.140-149
    • /
    • 2014
  • The purpose of this study was to investigate the influence of etching surface treatment and aging treatment of zirconia on the shear bond strength between zirconia core and veneered ceramic. Four groups of zirconia-ceramic specimens were prepared; 1) NEZ group (no etching zirconia), 2) EZ group (etching zirconia), 3) ANEZ group (aging and no etching zirconia), 4) AEZ group (aging and etching zirconia). The shear bond strength between zirconia and porcelain was measured using Instron Universal Testing Machine. Surface texture with crystalline structure of zirconia surface was examined by the field emission scanning electron microscopy (FE-SEM) with ingredient analysis. The fractured surfaces of specimens were examined to determine the failure pattern by a digital microscope. The mean${\pm}$standard deviation of shear bond strengths were $23.47{\pm}3.47$ Mpa in NEZ, $28.30{\pm}4.34$ Mpa in EZ, $21.85{\pm}4.65$ Mpa in ANEZ, $24.65{\pm}3.65$ Mpa in AEZ group, respectively, and were significantly different (p<0.05). The average shear bond strength was largest in EZ group, followed by AEZ, NEZ, and ANEZ groups. Most specimens in NEZ group showed adhesive failure and most specimens in EZ, AEZ, and ANEZ group showed mixed failure. Surface of etching treatment group (EZ and AEZ) showed complex micro-structure and irregular surface texture which may facilitate mechanical interlocking, while untreated zirconia surface presented simpler micro-structure. In conclusion, an etching treatment improved bonding strength between zirconia and porcelain by forming mechanical interlocking.

VORTEX STRUCTURE IN THE SCOUR HOLE BY GATE OPENING OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Choe, Jae-Wan
    • Water Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.83-92
    • /
    • 2000
  • Jet flow can occur by gate opening at downstream of a hydraulic structure such as weir of drainage gate. If the stream bed is not hard or the bed protection is not sufficient, vortex erosion occurs and a resulting scour hole will be formed due to the high shear stress of the jet flow. Once the scour hole is formed, a vortex occurs in ti and this vortex causes additional erosion. If this erosion continues and reaches to the hydraulic structure, it can undermine the bottom of the hydraulic structure and this will lead to failure of the structure itself. Thus, it is necessary to define the physical features of the vortex structure in the scour hole for the design of the bed protection. This study presents the turbulent vortex structure in the scour hole by the gate opening of the hydraulic structure. Characteristics of vortex motion, circulation, vortex scale and vortex were analyzed through experiments. Experimental results of the vortex velocity were compared with theoretical ones. From these, circulation and vortex scale were obtained with known values of inflow depth, inflow velocity and scale of scour hole

  • PDF

Effect of Adhesive Shear Strength of CFRP/Ni-Cr Alloy Under Severe Environmental Condition (가혹 환경이 복합재/Ni-Cr 합금 접착전단강도에 미치는 영향 연구)

  • Cho, Hyeon-Tae;Park, Seong-Min;Kim, Min-Jun;Hoang, Van-Tho;Kim, Hak-Inn;Son, Myung-Sook;Ahn, Jong-Kee;An, Ji-Min;Choi, Jin-Ho;Nam, Young-Woo;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.275-281
    • /
    • 2020
  • The mechanical property related to lap shear strength of the joint structure between carbon fiber reinforced polymer (CFRP) composite and metal (Ni-Cr Alloy) under varying environmental conditions (temperature and humidity) was studied in order to apply to the aircraft fan blade. Room temperature dry (RTD), elevated temperature wet (ETW), and cold temperature dry (CTD) environmental conditions were chosen for investigation based on the flight conditions of aircraft. Lap shear strength tests were conducted according to ASTM Standard D3528 to evaluate the shear strength. The microstructure characteristic of failure zone was analyzed by SEM images to check the adhesive shear strength with the three environmental conditions. In comparison with shear strength for the RTD condition, the shear strength in the ETW condition was reduced by 72.8% while those for the CTD condition increased by 56.5%. The moisture absorption and high temperature in ETW condition strongly had an affect on mechanical property of adhesive, while cold temperature could enhance the adhesive shear strength due to the higher brittleness.

Experimental Evaluation of the Punching Shear Strength with Lightweight Aggregate Concrete Slabs (경량골재 콘크리트 바닥판의 펀칭전단강도의 실험적 평가)

  • Kim, Jung-Joong;Moon, Ji-Ho;Youm, Kwang-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.361-367
    • /
    • 2014
  • This paper investigates the punching shear strength of lightweight aggregate concrete (LWAC) slabs through a series of experimental study. Five full scale slabs were constructed using normal concrete and four different types of LWAC. Each lightweight aggregate (LWA) used in this study had different sources (clay, shale, or slate) and shapes (crushed or spherical shape). Based on the test results, the effect of the lightweight aggregates (LWA) on the punching shear behavior was investigated. From the test results, it was found that the punching shear failure surface of LWAC slab with spherical shape coarse aggregate was less inclined than that with crushed shape coarse aggregate, which resulted in an increase of the area of the shear failure surface. As a result, it leads to the increased punching shear strength of the slab. On the other hand, the failure surfaces of LWAC slab with crushed shape coarse aggregate and normal coarse aggregate were inclined similarly. Finally, the test results of this study were compared with the punching shear strength obtained from current design models, such as ACI and CEB-FIP, to examine the validation of current design model to predict the punching shear strength of the LWAC slab.

Shear Resisting Effects of Protruded Nails by Pressure Grouting (가압식 돌기네일의 전단저항 효과)

  • Hong, Cheorhwa;Lee, Sangduk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.7
    • /
    • pp.13-20
    • /
    • 2017
  • Soil nailing is ground reinforcement method using the shear strength of ground and the pullout shear resistance force of nail. It is mainly used for reinforcement of cut slopes, earth retaining structures and retaining walls, etc. It may be designed considering the pullout resistance of nail in the case of earth retaining structure and retaining wall, but it should be designed considering not only pullout resistance but also shear and bending resistance in the case of slope. However, conservative designs considering only pullout resistance are being done and most of the studies are about increasing pullout resistance by improving of material, shape and construction method of nail. Actually, Shear bending deformations occur centering on the active surface in ground reinforced with the nail. The grout with relatively low strength is destroyed and separated from the reinforcing material. As a result, the ground is collapsed while reducing the frictional resistance rapidly. Therefore, it is necessary to develop the method to increase the shear resistance while preventing separation of nail and grout body. In this study, an experimental study was conducted on new soil nailing method which can increase shear resistance by forming protrusions through pressurized grouting after installing a packer on the outside of deformed bar.