• 제목/요약/키워드: shear structure

Search Result 2,353, Processing Time 0.035 seconds

Numerical finite element study of a new perforated steel plate shear wall under cyclic loading

  • Farrokhi, Ali-Akbar;Rahimi, Sepideh;Beygi, Morteza Hosseinali;Hoseinzadeh, Mohamad
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.539-548
    • /
    • 2022
  • Steel plate shear walls (SPSWs) are one of the most important and widely used lateral load-bearing systems. The reason for this is easier execution than reinforced concrete (RC) shear walls, faster construction time, and lower final weight of the structure. However, the main drawback of SPSWs is premature buckling in low drift ratios, which affects the energy absorption capacity and global performance of the system. To address this problem, two groups of SPSWs under cyclic loading were investigated using the finite element method (FEM). In the first group, several series of circular rings have been used and in the second group, a new type of SPSW with concentric circular rings (CCRs) has been introduced. Numerous parameters include in yield stress of steel plate wall materials, steel panel thickness, and ring width were considered in nonlinear static analysis. At first, a three-dimensional (3D) numerical model was validated using three sets of laboratory SPSWs and the difference in results between numerical models and experimental specimens was less than 5% in all cases. The results of numerical models revealed that the full SPSW undergoes shear buckling at a drift ratio of 0.2% and its hysteresis behavior has a pinching in the middle part of load-drift ratio curve. Whereas, in the two categories of proposed SPSWs, the hysteresis behavior is complete and stable, and in most cases no capacity degradation of up to 6% drift ratio has been observed. Also, in most numerical models, the tangential stiffness remains almost constant in each cycle. Finally, for the innovative SPSW, a relationship was suggested to determine the shear capacity of the proposed steel wall relative to the wall slenderness coefficient.

Effect of water distribution on shear strength of compacted loess

  • Kang-ze, Yuan;Wan-kui, Ni;Xiang-fei, Lu;Hai-man, Wang
    • Geomechanics and Engineering
    • /
    • v.31 no.5
    • /
    • pp.519-527
    • /
    • 2022
  • Shear failure in soil is the primary cause of most geotechnical structure failures or instability. Soil water content is a significant factor affecting soil shear strength. In this study, the shear strength of samples with different water contents was tested. The shear strength, cohesion, and internal friction angle decreased with increasing water content. Based on the variation of cohesion and internal friction angle, the water content zone was divided into a high-water content zone and low-water content zone with a threshold water content of 15.05%. Cohesion and internal friction angle have a good linear relationship with water content in both zones. Environmental Scanning Electron Microscopy (ESEM) test presented that the aggregates size of the compacted loess gradually increases with increasing water content. Meanwhile, the clay in the compacted loess forms a matric that envelops around the surface of the aggregates and fills the inter-aggregates pores. A quantitative analysis of bound water and free water under different water contents using a nuclear magnetic resonance (NMR) test was carried out. The threshold water content between bound water and free water was slightly below the plastic limit, which is consistent with the results of shear strength parameters. Combined with the T2 distributions obtained by NMR, one can define a T2 relaxation time of 1.58 ms as the boundary point for bound water distribution without free water. Finally, the effects of bound water and free water on shear strength parameters were analyzed using linear regression analysis.

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

Investigation of Load Transfer Characteristics at Slab Joints In The Floating Slab Track by Equivalent Shear Spring Model (등가 전단 스프링 모델을 이용한 플로팅 슬래브궤도 연결부에서의 하중전달 특성 분석)

  • Jang, Seung-Yup;Ahn, Mi-Kyoung;Choi, Won-Il;Park, Man-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2838-2843
    • /
    • 2011
  • Recently, the floating slab track that can effectively mitigate the vibration and structure-borne noise is being discussed to be adopted. The floating slab track which is a track system isolated from the sub-structure by vibration isolators. Unsimilarly to conventional track and the slab deflection is large. Therefore, the running safety and ride comfort should be investigated. Especially at slab joint since the load cannot be transferred, the possibility that the dynamic behavior of track and train became unstable is high. Thus, in general dowel bar are often installed at slab joints. To determine the appropriate dowel ratio the load transfer characteristics should be investigated. In this study, dowel bar joint is modeled by equivalent shear spring and this model is verified by comparison with experimental results. Using the proven model, the load transfer efficiency and deflection at slab joint according to dowel ratio, and stiffness and spacing of vibration isolator were examined.

  • PDF

Efficient Vibration Analysis of Floors in A Shear Wall Building Structure (벽식구조물 바닥의 효율적인 진동해석)

  • 김현수;이동근;이선화
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.357-364
    • /
    • 2004
  • Recently, many high-rise apartment buildings using the box system composed of only reinforced connote walls and slabs, have been constructed In residential buildings such as apartments, vibrations occur from various sources and these vibrations transfer to neighboring residential units through walls and slabs. It is necessary to use a refined finite element model for an accurate vibration analysis of shear wall building structures. But it would take significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. Therefore an efficient analytical method, which has only translational DOFs perpendicular to walls or slabs by the matrix condensation technique, is proposed in this study to obtain accurate results in significantly reduced computational time.

  • PDF

Three-dimensional effective properties of layered composites with imperfect interfaces

  • Sertse, Hamsasew;Yu, Wenbin
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.6
    • /
    • pp.639-650
    • /
    • 2017
  • The objective of this paper is to obtain three-dimensional (3D) effective properties for layered composites with imperfect interfaces using mechanics of structure genome. The imperfect interface is modeled using linear traction-displacement model that allows small infinitesimal displacement jump across the interface. The predictions obtained from the current analysis are compared with the 3D finite element analysis (FEA). In this study, it is found that the present model shows excellent agreement with the results obtained using 3D FEA by employing periodic boundary conditions. The prediction also reveals that in-plane longitudinal and shear moduli, and all Poisson's ratios are observed to be not affected by the interfacial stiffness while the predictions of transverse longitudinal and shear moduli are significantly influenced by interfacial stiffness.

Development of a Wall Analysis Model Grafting FE-BEM (FE-BEM을 결합한 벽체의 해석모델 개발)

  • Jung , Nam-Su;Choi, Won;Lee, Ho-Jae;Kim , Han-Joong;Lee , Jeong-Jae;Kim, Jong-Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.61-68
    • /
    • 2004
  • Methodologies of the finite element and boundary element are combined to achieve an efficient and accurate analysis model of frame structure containing shear wall. This model analyzes the frame by employing the finite element method and the shear wall by boundary element method. This study is applicable to a specific situation, where the boundary element is surrounded by finite elements. By employing FE dominant method in which boundary stiffness matrix is transformed into finite element stiffness matrix, boundary element and finite element method are combined to analyze frame structure with walls.

Structure of Turbulent Premixed Opposed Impinging Jet Flame with Simultaneous PIV/OH PLIF Measurements (PIV/OH PLIF 동시측정을 이용한 난류 대향 분출 예혼합화염 구조 연구)

  • Cho, Yong-Jin;Kim, Ji-Ho;Cho, Tae-Young;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.1
    • /
    • pp.36-45
    • /
    • 2003
  • The subject of turbulent premixed flames has been focused by many researchers for a number of decades. Especially, Borghi suggested a magnificent diagram classifying turbulent combustion areas and Lipatnikov and Chomiak modified this diagram. Recently, experimental techniques have been developed so that we can use PIV for measuring 2D velocity field and apply OH PLIF techniques for obtaining flame locations. In present study, a new diagram is proposed using strain rates and OH signal intensity. Thus, simultaneous PIV and OH PLIF measurements are used for shear strain rates and flame locations, respectively. It is believed that the shear strain rates represent flow characteristics such as turbulence intensity and the OH intensity indicates the flame characteristics such as burning velocities.

  • PDF

Flight Loads Analysis for Conceptual Study of the Regional Aircraft Wing Structure (중형항공기 주익 구조개발 선행연구를 위한 비행하중해석)

  • Shin, Jeong-Woo;Kang, Wang-gu;Kim, Sung-Joon;Hwang, In-Hee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.4
    • /
    • pp.67-73
    • /
    • 2011
  • For loads analysis of airplane, applicable regulation should be determined. Then, loads conditions are prepared from the regulation. Modeling for aerodynamic, mass, and structure are performed. Panel method is usually adopted for aircraft loads analysis to obtain air loads. The ARGON which is a multidisciplinary fixed wing aircraft design software co-developed by the KARI and TsAGI are used for loads analysis. The ARGON can be utilized for flutter and stress analysis as well as for flight and ground loads analysis. In this paper, flight loads analysis for wing structural design of the regional aircraft at the conceptual design phase are performed with the ARGON. FAR 25 is used for the regulation for the load analysis. Shear force, bending moment and torsion diagrams for the wing and shear force and hinge moment for the aileron are presented.

Turbulence Structures of Flow in Concentric Annuli with Rough Outer Wall (외벽에 거칠기가 있는 이중동심관 유동의 난류구조)

  • 김경천;안수환;이병규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2443-2453
    • /
    • 1994
  • The structure of turbulence of fully developed flow through four concentric annuli with the rough outer wall was investigated experimentally for a Reynolds number range Re=15, 000-93, 000. Turbulence intensities were measured in three(u, v, w) directions, and turbulence shear stresses in annuli of radius=0.13, 0.26, 0.4 and 0.56, respectively. Due to the square roughness element attached periodically along the axial direction, the radial velocity fluctuations show similar distribution regardless of the different .alpha.cases. However, the axial and circumferential velocity fluctuation profiles demonstrate the longitudinal turbulence structures are strongly influenced by the .alpha. values. The turbulent eddy viscosity deduced form mean velocity distributions and the measured Reynolds shear stresses are also presented and discussed.