• Title/Summary/Keyword: shear structure

Search Result 2,353, Processing Time 0.037 seconds

Reynolds Shear Stress Distribution in Turbulent Channel Flows (난류 채널 유동 내부의 레이놀즈 전단 응력 분포)

  • Kim, Kyoung-Youn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.829-837
    • /
    • 2012
  • Direct numerical simulations were carried out for turbulent channel flows with $Re_{\tau}$ = 180, 395 and 590 to investigate the turbulent flow structure related to the Reynolds shear stress. By examining the probability density function, the second quadrant (Q2) events with the largest contribution to the mean Reynolds shear stress were identified. The change in the inclination angle of Q2 events varies with wall units in $y^+<50$ and with the channel half height in y/h > 0.5. Conditionally averaged flow fields for the Q2 event show that the flow structures associated with Reynolds shear stress are a quasi-streamwise vortex in the buffer layer and a hairpin-shaped vortex in the outer layer. Three-dimensional visualization of the distribution of high Reynolds shear stress reveals that the organization of hairpin vortices in the outer layer having a size of 1.5~3 h is associated with large-scale motions with high Reynolds shear stress in the outer layer.

EFFECT OF LASER IRRADIATION ON DENTIN SURFACE STRUCTURE AND SHEAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER. (상아질 표면 구조와 광중합형 글라스 아이오노머의 전단강도에 대한 레이저 조사의 효과)

  • Park, Mi-Ryoung;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.76-92
    • /
    • 1998
  • The purpose of this study was to evaluate the possible efficacy of Nd-YAG laser as a dentin conditioner by observing the laser irradiation dentin surface under scanning electron micrograph and measuring shear bond strength of restored light-cured glass ionomer mold. Fifty intact premolars were prepared for shear bond strength tests. The teeth were randomly divided into five groups as follows; Group I. no treatment Group II. 10% poly acrylic acid, 20 sec Group III. laser treatment 2 w, 20 Hz, 2 sec Group IV. laser treatment 2 w, 20 Hz, 5 sec Group V. laser treatment 2 w, 20 Hz, 10 sec Samples of each group were restored with light-cured glass ionomer cement after dentin conditioning and then measuring the shear bond strength of each specimen were measured using universal testing machine. Additional ten premolars were prepared for SEM analysis The result from the this study can be summarized as follows. 1. Shear bond strength of polyacrylic acid-treated group (II) was significantly higher than other groups (p<0.05). 2. No statistically significant difference could be found between three laser-treated groups (III, IV, V) in shear bond strength(p>0.05) 3. According to the result of observation under SEM, Polyacrylic acid was shown to have removed the smear layer effectively and opened the dentinal tubules, whereas the laser has produced the irregular surface mainly composed of melted and fused structure. The microcracks found in laser-treated groups increased in number with irradiation time and formed the regular mesh-type in 10 sec-irradiation group. 4. The ultrastructural change of dentin surface created by laser irradiation was found to the improper for bonding of the glass ionomer restorative materials. And the lower shear bond strength of laser irradiated group might have been due to the failure to form the suit able dentin surface for the glass ionomer to penetrated into and form the proper micromechanical retention.

  • PDF

Seismic performance assessments of precast energy dissipation shear wall structures under earthquake sequence excitations

  • Zhang, Hao;Li, Chao;Wang, Zhi-Fang;Zhang, Cai-Yan
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.147-162
    • /
    • 2020
  • This paper presents a novel precast energy dissipation shear wall (PEDSW) structure system that using mild steel dampers as dry connectors at the vertical joints to connect adjacent wall panels. Analytical studies are systematically conducted to investigate the seismic performance of the proposed PEDSW under sequence-type ground motions. During earthquake events, earthquake sequences have the potential to cause severe damage to structures and threaten life safety. To date, the damage probability of engineering structures under earthquake sequence has not been included in structural design codes. In this study, numerical simulations on single-story PEDSW are carried out to validate the feasibility and reliability of using mild steel dampers to connect the precast shear walls. The seismic responses of the PEDSW and cast-in-place shear wall (CIPSW) are comparatively studied based on nonlinear time-history analyses, and the effectiveness of the proposed high-rise PEDSW is demonstrated. Next, the foreshock-mainshock-aftershock type earthquake sequences are constructed, and the seismic response and fragility curves of the PEDSW under single mainshock and earthquake sequences are analyzed and compared. Finally, the fragility analysis of PEDSW structure under earthquake sequences is performed. The influences of scaling factor of the aftershocks (foreshocks) to the mainshocks on the fragility of the PEDSW structure under different damage states are investigated. The numerical results reveal that neglecting the effect of earthquake sequence can lead to underestimated seismic responses and fragilities, which may result in unsafe design schemes of PEDSW structures.

Performance Assessment of Precast Concrete Segmental Bridge Columns with Shear Resistance Connecting Structure (전단저항 연결체를 갖는 프리캐스트 세그먼트 교각의 성능평가)

  • Kim, Tae-Hoon;Kim, Young-Jin;Kim, Seong-Woon;Shin, Hyun-Mock
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.591-601
    • /
    • 2008
  • The purpose of this study was to investigate the performance of precast concrete segmental bridge columns with shear resistance connecting structure. The system can reduce work at a construction site and makes construction periods shorter. A model of precast concrete segmental bridge columns with shear resistance connecting structure was tested under a constant axial load and a cyclically reversed horizontal load. A computer program, RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. An bonded or unbonded tendon element based on the finite element method, that can represent the interaction between tendon and concrete of prestressed concrete member, is used. A joint element is newly modified to predict the inelastic behaviors of segmental joints. The proposed numerical method gives a realistic prediction of performance throughout the loading cycles for several test specimens investigated.

Shape Optimal Design of Variable Sandwich Structure (가변 샌드위치 구조물의 형상최적설계)

  • 박철민;박경진;이완익
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2162-2171
    • /
    • 1993
  • Geneal Structure optimization is utilized to minimize the weight of structures while satisfying constraints imposed on stress, displacements and natural frequencies, etc. Sandwich structures consist of inside core and outside face sheets. The selected sandwich structures are isotropic sandwich beams and isotropic sandwich plate. The face sheets are treated as membrane and assumed to carry only tensions, while the core is assumed to carry only transverse shear. The characteristic of the varying area are considered by adding the projected component of the tension to the transverse shear. The bending theory and energy method are adopted for analyzing sandwich beams and plates, respectively. In the optimization process, the cost function is the weight of a structure, and a deflection and stress constraints are considered. Design variable are thickness and tapering coefficients which determine the shape of a structure. An existing optimization code is used for solving the formulated problems.

Transmitted Force Estimation of Prototype HIF System Considering Flexibility of Mount System (지지부 동특성을 고려한 HIF 시스템의 충격력 예측)

  • Kim Hyo Jun;Choe Eui Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.107-112
    • /
    • 2005
  • In this study, the dynamic analysis is performed fur predicting the transmitted force to flexible human body induced by prototype HIF(High Impulsive force) device operation, which is partially assembled by major parts. A beam-mass model and a shear-structure model are used for the flexible mount structure and their dynamic behavior are investigated by experimental results under rigid/flexible mount conditions using a general purpose device. From the test result of prototype device in rigid mount condition, the transmitted force to human body which can not be measured directly, is estimated based on the proved mount structure model.

Dynamic buckling of smart sandwich beam subjected to electric field based on hyperbolic piezoelasticity theory

  • Shokravi, Maryam
    • Smart Structures and Systems
    • /
    • v.22 no.3
    • /
    • pp.327-334
    • /
    • 2018
  • In this paper, dynamic buckling of the smart subjected to blast load subjected to electric field is studied. The sandwich structure is rested on Pasternak foundation with springs and shear elements. Applying piezoelasticity theory and hyperbolic shear deformation beam theory (HSDBT), the motion equations are derived by energy method. For calculating the dynamic instability region (DIR) of the sandwich structure, differential quadrature method (DQM) along with Bolotin method is used. The aim of this study is to investigate the effects of applied voltage, geometrical parameters of structure and boundary conditions on the DIR of the structure. The results show that applying negative voltage, the DIR will be happened at higher excitation frequencies. In addition, the clamped-clamped beam leads to higher excitation frequency with respect to simply supported boundary condition.

Relationship between Replication and Structure of Micro/Nano Molded Parts

  • Ito, Hiroshi;Kazama, Kunihiko;Kikutani, Takeshi
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.368-368
    • /
    • 2006
  • Micro-molded parts can be defined as parts with microgram weight, parts with micro-structured surface, and parts with micro-precision. In this study, various micro-scale molded parts for various polymers were produced by using a precision micro-molding machine. Molded parts with nano-structure surface were also produced to analyze the effect of molding conditions on replication of surface pattern and higher-order structure development of molded parts. Replication of molded parts was influenced by material properties, molding conditions and size of surface pattern. Higher-order structure of molded parts was investigated by using polarized microscope. Skin-shear-core regions inside the molded parts were observed and shear region affected to surface replication.

  • PDF

Fluid-structure interactions of physiological flow in stenosed artery

  • Buriev, Bahtiyor;Kim, Tae-Dong;Seo, Tae-Won
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.1
    • /
    • pp.39-46
    • /
    • 2009
  • Atherosclerosis is a disease that narrows, thickens, hardens, and restructures a blood vessel due to substantial plaque deposit. The geometric models of the considered stenotic blood flow are three different types of constriction of cross-sectional area of blood vessel; 25%, 50%, and 75% of constriction. The computational model with the fluid-structure interaction is introduced to investigate the wall shear stresses, blood flow field and recirculation zone in the stenotic vessels. The velocity profile in a compliant stenotic artery with various constrictions is subjected to prescribed physiologic waveform. The computational simulations were performed, in which the physiological flow through a compliant axisymmetric stenotic blood vessel was solved using commercial software ADINA 8.4 developed by finite element method. We demonstrated comparisons of the wall shear stress with or without the fluid-structure interaction and their velocity profiles under the physiological flow condition in the compliant stenotic artery. The present results enhance our understanding of the hemodynamic characteristics in a compliant stenotic artery.

Nonlinear Seismic Analysis of Steel Structure Buildings Considering the Stiffnesses of the Foundation-Soil System (기초지반강성을 고려한 철골 건축구조물의 비선형 지진해석)

  • Oh, Young-Hee;Kim, Yong-Seok
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.137-144
    • /
    • 2005
  • Seismic responses of a building are affected due to the site soil conditions. In this study, linear time history seismic analysis and nonlinear pushover static seismic analysis were performed to estimate the base shear forces of the 3, 5 and 7-story steel structure buildings considering the rigid and soft soil conditions. According to the study results, the steel structure buildings designed for the gravity loads and wind load showed the elastic responses with the moderate earthquake of 0.11g, and the soft soil layer increased the displacement and the base shear force of a building. Therefore it is more resonable to perform an elastic seismic analysis of a building structure with the moderate earthquakes considering the characteristics of the soft soil layer.

  • PDF