• 제목/요약/키워드: shear span

검색결과 629건 처리시간 0.024초

철근콘크리트 연속 깊은 보의 전단내력 평가에 대한 실험적 연구 (An Experimental Study on the Evaluation of Shear Strength in Reinforced Concrete Continuous Deep Beams)

  • 양근혁;정헌수;박정화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.393-396
    • /
    • 2004
  • The objective of this experimental study is to understand the shear behavior of reinforced concrete continuous deep beams. The main variables considered were concrete strength and shear span-to-depth ratio. Specimens of 4 two-span continuous deep beams were tested and compared with the strength of simple span beams. The results show that the influence of concrete strength on the shear strength of continuous deep beams is comparable to that on simple span deep beams. However, the effect of span-to-depth ratio is significantly greater than simple span deep beams.

  • PDF

전단-스팬비가 작은 고강도철근콘크리트 보의 전단성능 (Shear Capacity of Higth-Strength Concrete Beams With a Shear Span-Depth Ratio Between 1.5 and 2.5)

  • 문정일;안종문;김대근;이광수;이승훈;오정근;장일영;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.106-110
    • /
    • 1992
  • This paper is an experimental study on shear capacity of the high strength R/C beams with a shear span-depth ratio between 1.5 and 2.5. a total of 15 beams was tested to determine diagonal cracking and ultimate shear strength. The major variables are shear span-depth ratio (a/d=1.5, 2.0. 2.5) , vertical shear reinforcements ratio(Vs = 0 , 25, 50, 75, 100% ( Vs = Pv/Pv(ACI)), and concrete compressive strength (f'c= 747㎏/㎠). Test results indicate that ACI 318-89 Eq(11-31) generally underestimates shear strength carried by vertical shear reinforcements, and the mode of failure may change from shear tension to shear compression for the beams having higher Vs than 75%, thus the effectiveness of r-fy on ultimate shear strength (vu) decreased.

  • PDF

Design for shear strength of concrete beams longitudinally reinforced with GFRP bars

  • Thomas, Job;Ramadassa, S.
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.41-55
    • /
    • 2015
  • In this paper, a model for the evaluation of shear strength of fibre reinforced polymer (FRP)-reinforced concrete beams is given. The survey of literature indicates that the FRP reinforced beams tested with shear span to depth ratio less than or equal to 1.0 is limited. In this study, eight concrete beams reinforced with GFRP rebars without stirrups are cast and tested over shear span to depth ratio of 0.5 and 1.75. The concrete compressive strength is varied from 40.6 to 65.3 MPa. The longitudinal reinforcement ratio is varied from 1.16 to 1.75. The experimental shear strength and load-deflection response of the beams are determined and reported in this paper. A model is proposed for the prediction of shear strength of beams reinforced with FRP bars. The proposed model accounts for compressive strength of concrete, modulus of FRP rebar, longitudinal reinforcement ratio, shear span to depth ratio and size effect of beams. The shear strength of FRP reinforced concrete beams predicted using the proposed model is found to be in better agreement with the corresponding test data when compared with the shear strength predicted using the eleven models published in the literature. Design example of FRP reinforced concrete beam is also given in the appendix.

Effect of shear wall location in rigid frame on earthquake response of roof structure

  • Ishikawa, Koichiro;Kawasaki, Yoshizo;Tagawa, Kengo
    • Structural Engineering and Mechanics
    • /
    • 제11권6호
    • /
    • pp.605-616
    • /
    • 2001
  • The purpose of this study is to investigate the effect of the shear wall location in rigid frames on the dynamic behavior of a roof structure due to vertical and horizontal earthquake motions. The study deals with a gabled long span beam supported by two story rigid frames with shear walls. The earthquake response analysis is carried out to study the responses of the roof: vibration mode, natural period, bending moment and horizontal shear force of the bearings. The study results in the following conclusions: First, a large horizontal stiffness difference between the side frames is caused by the shear wall location, which results in a large vertical vibration of the roof and a large shear force at the side bearings. Second, in this case, the seismic design method for ordinary buildings is not useful in determining the distribution of the static equivalent loads for the seismic design of this kind of long span structures.

Experimental study on shear capacity of circular concrete filled steel tubes

  • Xiao, Congzhen;Cai, Shaohuai;Chen, Tao;Xu, Chunli
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.437-449
    • /
    • 2012
  • Concrete filled steel tube (CFST) structures have recently seen wide use in China, but studies of the shear problem of CFST are inadequate. This paper presents an experimental study on the shear capacity of circular concrete filled steel tube (CCFT) specimens with and without axial compression force. Shear capacity, ductility, and damage modes of CCFTs were investigated and compared. Test results revealed the following: 1) CCFTs with a small shear span ratio may fail in shear in a ductile manner; 2) Several factors including section size, material properties, shear span ratio, axial compression ratio, and confinement index affect the shear capacity of CCFTs. Based on test results and analysis, this paper proposes a design formula for the shear capacity of CCFTs.

집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 관한 실험적 연구 (An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads)

  • 이진섭;김상식
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.191-200
    • /
    • 1999
  • 집중하중을 받는 단순지지 철근콘크리트 깊은 보를 대상으로 콘크리트의 압축강도, 전단스팬비, 웨브 수직 및 수평 보강철근비를 변수로 하여 깊은 보의 구조거동과 전단강도를 실험적으로 조사하였으며, 각 변수의 영향을 고찰하고 규준식 및 제안식 등과 비교, 검토하였다. 42개의 시험체를 실험한 결과, 모든 시험체는 전단스팬 내에서 콘크리트의 과도한 균열 및 압괴에 의해 파괴되었고, 시험체의 초기강성은 압축강도에 관계없이 전단 스팬비가 작을수록 크게 나타났으며, 경사균열 발생 이후 보의 강성이 점진적으로 감소되었다. 전단스팬비가 증가함에 따라 경사균열 및 최대하중은 일정하게 감소하며, 콘크리트 압축강도가 증가할수록 최대하중은 증가하나 경사균열 하중은 거의 변화가 없었고, 전단스팬비의 증가에 따라 콘크리트의 압축강도가 전단강도에 미치는 영향 또한 일정하게 감소하는 것으로 보인다. 웨브의 전단보강근 효과는 전단스팬비의 영향을 받으며, 전단스팬비가 작아지면 수평보강근의 효과가, 전단스팬비가 커지면 수직보강근의 효과가 상대적으로 커짐을 알 수 있었다. 실험결과와 비교하여, 이론식은 de Paiva의 제안식이, 규준식은 CIRIA guide가 실험결과에 가장 부합하는 것으로 나타났으며, 국내 규준식은 실험값에 비해 상당히 낮은 강도로 계산되고 있어 안전 측에 있는 것으로 판단된다.

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

전단경간비와 주인장철근비가 철근콘크리트 보의 최소전단철근비에 미치는 영향 (Effects of Shear Span-to-depth Ratio and Tensile Longitudinal Reinforcement Ratio on Minimum Shear Reinforcement Ratio of RC Beams)

  • 이정윤;김욱연;김상우;이범식
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.795-803
    • /
    • 2004
  • 현행 구조설계기준식에서는 취성적으로 파괴하는 최소전단보강철근 파괴를 방지하기 위하여 철근콘크리트 보에 최소전단보강철근을 배근하도록 규정하고 있다. 최소전단철근비는 콘크리트의 압축강도와 함께 주인장철근비와 전단경간비에 영향을 받는다. 이 연구에서는 주인장철근비와 전단경간비가 철근콘크리트 보의 최소전단철근비에 미치는 영향을 파악하기 위하여 14개의 철근콘크리트 보를 실험하였다. 실험에 의하면 전단 여유율은 주인장철근비가 증가할수록 증가하였고, 전단경간비가 증가할수록 감소하였다. 실험 결과는 ACI 318-02 기준식과 선행 연구의 제안식과 비교되었다.

FRP 보강근을 사용한 콘크리트 보의 콘크리트 전단강도 (Concrete Shear Strength of FRP Reinforced Concrete Beam)

  • 조재민;장희석;김명식;김충호
    • 대한토목학회논문집
    • /
    • 제29권3A호
    • /
    • pp.259-266
    • /
    • 2009
  • 본 연구에서는 전단보강이 없는 FRP 보강근을 사용한 콘크리트 보의 제작 및 파괴실험을 통하여 FRP bar와 철근의 탄성계수비, 휨보강근비 및 전단지간비의 영향을 동시에 고려하여 콘크리트 전단강도를 평가할 수 있는 수식을 제안하였다. 실험변수로서 2종류의 FRP bar, 3종류의 전단지간비 및 3종류의 휨보강근비를 사용하였으며, 총 36개의 FRP 보강근을 사용한 콘크리트 보를 제작하고 4점 휨 실험을 수행하였다. 전단지간비의 영향을 상세히 분석하기 위하여 앞서 연구된 2종류의 전단지간비에 대한 실험결과를 인용하였다. 실험자료들을 회귀분석하여 콘크리트 전단강도 계산에 필요한 전단강도보정계수를 구하는 수식을 제안하였다. 제안된 수식의 검증을 하기 위하여 여러 문헌으로부터 조사된 31개의 실험결과에 대하여 본 연구의 제안식과 다른 연구자들이 제안한 수식들을 함께 적용하여 비교 분석하였다. 그 결과, 본 연구에서 제안된 수식은 실험결과에 가장 근접하는 결과를 주는 것을 알 수 있었다.

산업부산물을 활용한 고강도경량 콘크리트보의 거동 특성 (A Study on the Behavior Properties of the High-Strength Lightweight Concrete Beam Using the Industrial By-Products)

  • 이승조;박정민;손영호;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.188-191
    • /
    • 2004
  • We experimented variables of four kinds(a/d=1.5, 2.5, 3.5, 4.5) of shear span ratio to consider a structural characteristic of high-strength lightweight concrete beam used industrial by-product. Through the research of serials, the more increase of shear span ratio, the more ductility is superior. Rating the capacity of high-strength concrete beam and the capacity of lightweight concrete beam, in existing lightweight concrete beam evaluation formula, if a shear strength formula for normal concrete multiplies 0.85(reduction factor), it is rated as safety side over shear span ratio 2.5, but it is riskful at low shear span ratio. Therefore it is important that these factors are considered as the evaluation.

  • PDF