• Title/Summary/Keyword: shear interaction

Search Result 707, Processing Time 0.03 seconds

Prediction of Effective Wake Considering Propeller-Shear-Flow Interaction (선미후류-프로펠러 상호작용을 고려한 유효반류 추정법)

  • Chang-Sup,Lee;Jin-Tae,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.2
    • /
    • pp.1-12
    • /
    • 1990
  • Interactions between a propeller and vortex system contained in a ship stern flow is treated theoretically. A new formulation to determine the effective velocity distributions is developed, which may be immediately applicable to the design and analysis of compound propulsors under the influence of severe vortical cross-flows around ship stern. An axisymmetric shear flow is represented by a system of ring vortices and the axial variation of the stream lines due to the action of propeller is represented by a cubic function. The strengths of ring vortices, which are varying along the stream lines, are determined by the conservation of angular momentum. Two simplified effective velocity models are proposed to confirm the theory. Sample calculations using the simplified models are made to compare with the results by other investigators.

  • PDF

The influence of tunnelling on the behaviour of pre-existing piled foundations in weathered soil

  • Lee, Cheol-Ju;Jeon, Young-Jin;Kim, Sung-Hee;Park, Inn-Joon
    • Geomechanics and Engineering
    • /
    • v.11 no.4
    • /
    • pp.553-570
    • /
    • 2016
  • A series of three-dimensional (3D) parametric finite element analyses have been performed to study the influence of the relative locations of pile tips with regards to the tunnel position on the behaviour of single piles and pile groups to adjacent tunnelling in weathered soil. When the pile tips are inside the influence zone, which considers the relative pile tip location with respect to the tunnel position, tunnelling-induced pile head settlements are larger than those computed from the Greenfield condition. However, when the pile tips are outside the influence zone, a reverse trend is obtained. When the pile tips are inside the influence zone, the tunnelling-induced tensile pile forces mobilised, but when the pile tips are outside the influence zone, compressive pile forces are induced because of tunnelling, depending on the shear stress transfer mechanism at the pile-soil interface. For piles connected to a cap, tensile and compressive forces are mobilised at the top of the centre and side piles, respectively. It has been shown that the increases in the tunnelling-induced pile head settlements have resulted in reductions of the apparent factor of safety up to approximately 43% when the pile tips are inside the influence zone, therefore severely affecting the serviceability of the piles. The pile behaviour, when considering the location of the pile tips with regards to the tunnel, has been analysed in great detail by taking the tunnelling-induced pile head settlements, axial pile forces, apparent factor of safety of the piles and shear transfer mechanism into account.

Evaluation of rock load based on critical shear strain concept on tunnels (한계전단변형률 개념을 이용한 터널의 지반이완하중 평가)

  • Kim, Jung-Joo;Lee, Jae-Kook;Kim, Jong-Uk;Yoo, Han-Kyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.6
    • /
    • pp.637-652
    • /
    • 2013
  • After studying the characteristics of three different evaluation methods of rock load; namely theoretical method, empirical method and numerical method, there were too many limitations for them to be applied on tunnels. Therefore, in this research paper, the method based on numerical analysis is selected to use as this method is the most reasonable one since it considers all parameters that are necessary for rock load estimations, and it also considers the interaction between ground and tunnel support. The critical shear strain concept formulated by Sakurai (1981) was used in order to measure exact rock load values based on numerical analysis. Evaluation on a Level 1 rock load height, which is depicted by the stable region in the graph shows that rock load is not affecting between ground grade 1~3, and it was evaluated that the fourth and fifth grades show less values of rock load height which led to the conclusion of a more economical design of concrete lining.

Estimation of Rheological Properties of Highly Concentrated Polymer Bonded Explosive Simulant by Microstructure Analysis (미세구조 해석을 통한 고농축 복합화약 시뮬란트의 유변물성 예측)

  • Lee, Sangmook;Hong, In-Kwon;Lee, Jae Wook;Shim, Jung Seob
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.225-231
    • /
    • 2014
  • The rheological properties of highly concentrated polymer bonded explosive simulant were studied by using poly(ethylene-co-vinyl acetate) with 30 and 60% vinyl acetate (VA) content as a binder, respectively. Calcium carbonate and Dechlorane, whose physical properties are similar to resarch department explosive (RDX)'s, were used as fillers. The suspensions were mixed in a batch melt mixer and it was possible to fill 75 v% at maximum. From dynamic mechanical analysis, Dechlorane showed higher interaction with binder resins than that with calcium carbonate fillers. The effects of microstructural change on the rheological properties of the suspensions were investigated by a plate-plate rheometer with constant shear rate and constant shear stress modes, respectively. The theoretical maximum packing fraction of EVA31/Dechlorane suspension obtained from Krieger-Dougherty equation was 70 v% and it was thought that 2000 Pa was proper shear stress condition for this melt processing.

A Study on the Steering Characteristics of Tandem Tracked Vehicle on Extremely Cohesive Soft Soil (연약지반 직렬 무한궤도 주행차량의 선회특성 연구)

  • Kim, Hyung-Woo;Lee, Chang-Ho;Hong, Sup;Choi, Jong-Su;Yeu, Tae-Kyeong;Kim, Sea-Moon
    • Ocean and Polar Research
    • /
    • v.32 no.4
    • /
    • pp.361-367
    • /
    • 2010
  • The principal objective of this paper was to evaluate the steering characteristics of a tandem tracked vehicle, each side of which features two tandem tracks, when crawling on extremely cohesive soft soil. The tandem tracked vehicle is assumed to be a rigid-body with 6-dof. The dynamic analysis program of the tandem tracked vehicle was developed via Newmark's method and the incremental-iterative method. A terra-mechanics model of extremely cohesive soft soil was implemented according to the relationships of normal pressure to sinkage, of shear resistance to shear displacement, and of dynamic sinkage to shear displacement. In order to simplify the characteristics of contact interaction between track segments and cohesive soft soil, the characteristics of soil are equated to the properties of intact soil. In an effort to evaluate the steering characteristics of a tandem tracked vehicle crawling on extremely cohesive soft soil, a series of dynamic simulations were conducted for a tandem tracked vehicle model with respect to the front and rear steering angle, the steering ratio, and the initial velocity.

Characteristics of Shear Layer Vortices in Crossflow Jets According to the Inlet Conditions (초기조건변화에 따른 횡단류 제트 유동의 전단층와류 거동 특성)

  • Kim, Gyeong-Cheon;Kim, Sang-Gi;Yun, Sang-Yeol;Lee, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.394-401
    • /
    • 2002
  • The instantaneous flow characteristics of a round jet issuing normally into a crossflow has been studied using a flow visualization technique and particle image velocimetry. The effects of parameters such as jet inflow profile and turbulence intensity of the jet are evaluated for various Reynolds numbers in range between 735 and 3150, which are based on the crossflow velocity and jet-pipe diameter. The jet-to-crossflow velocity ratio is fixed at the value of 3.3. Instantaneous later tomographic images of the symmetry plane of the crossflow jet show that there exist very different natures in the flow structures of the near-field of the jet even though the velocity ratio is same. It is found that when the turbulence intensity of jet is elevated, the shear layer becomes much thicker due to the strong entrainment of the ambient fluid by turbulent interaction between the jet and crossflow. The detailed characteristics of instantaneous velocity and vorticity fields are presented to illustrate the effects of the above parameters on the vertical structures of the crossflow jet.

Analysis of the Relationship between Unconfined Compression Strength and Shear Strength of Frozen Soils (동결토의 일축압축강도와 전단강도 상관관계 분석에 관한 연구)

  • Kang, Jae-Mo;Lee, Jang-Guen;Lee, Joonyong;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.23-29
    • /
    • 2013
  • The mechanical behavior of frozen soils is different from that of unfrozen soils due to the phase change between water and ice. The strength characteristics of frozen soils are governed by the intrinsic material properties such as grain size, ice and water content, air bubbles, and by externally imposed testing conditions such as temperature, freezing time, and strain rate. Especially, the strength of the frozen soils is generally higher than that of unfrozen soils due to ice binding capacity with soil particles, and is strongly affected by a highly complex interaction between the solid soil skeleton and the pore matrix, composed of ice and unfrozen water. In this study, the direct shear test and unconfined compression test are carried out inside of a large-scaled freezing chamber, and the relationships between cohesion and unconfined compression strength under various freezing temperature conditions are discussed.

Racking shear resistance of steel frames with corner connected precast concrete infill panels

  • Hoenderkamp, J.C.D.;Snijder, H.H.;Hofmeyer, H.
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1403-1419
    • /
    • 2015
  • When precast concrete infill panels are connected to steel frames at discrete locations, interaction at the structural interface is neither complete nor absent. The contribution of precast concrete infill panels to the lateral stiffness and strength of steel frames can be significant depending on the quality, quantity and location of the discrete interface connections. This paper presents preliminary experimental and finite element results of an investigation into the composite behaviour of a square steel frame with a precast concrete infill panel subject to lateral loading. The panel is connected at the corners to the ends of the top and bottom beams. The Frame-to-Panel-Connection, FPC4 between steel beam and concrete panel consists of two parts. A T-section with five achor bars welded to the top of the flange is cast in at the panel corner at a forty five degree angle. The triangularly shaped web of the T-section is reinforced against local buckling with a stiffener plate. The second part consists of a triangular gusset plate which is welded to the beam flange. Two bolts acting in shear connect the gusset plate to the web of the T-section. This way the connection can act in tension or compression. Experimental pull-out tests on individual connections allowed their load deflection characteristics to be established. A full scale experiment was performed on a one-storey one-bay 3 by 3 m infilled frame structure which was horizontally loaded at the top. With the characteristics of the frame-to-panel connections obtained from the experiments on individual connections, finite element analyses were performed on the infilled frame structures taking geometric and material non-linear behaviour of the structural components into account. The finite element model yields reasonably accurate results. This allows the model to be used for further parametric studies.

Study on the behaviour of pre-existing single piles to adjacent shield tunnelling by considering the changes in the tunnel face pressures and the locations of the pile tips

  • Jeon, Young-Jin;Jeon, Seung-Chan;Jeon, Sang-Joon;Lee, Cheol-Ju
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.187-200
    • /
    • 2020
  • In the current work, a series of three-dimensional finite element analyses have been conducted to investigate the behaviour of pre-existing single piles in response to adjacent tunnelling by considering the tunnel face pressures and the relative locations of the pile tips with respect to the tunnel. Via numerical modelling, the effect of the face pressures on the pile behaviour has been analysed. In addition, the analyses have concentrated on the ground settlements, the pile head settlements and the shear stress transfer mechanism at the pile-soil interface. The settlements of the pile directly above the tunnel crown (with a vertical distance between the pile tip and the tunnel crown of 0.25D, where D is the tunnel diameter) with a face pressure of 50% of the in situ horizontal soil stress at the tunnel springline decreased by approximately 38% compared to the corresponding pile settlements with the minimum face pressure, namely, 25% of the in situ horizontal soil stress at the tunnel springline. Furthermore, the smaller the face pressure is, the larger the tunnelling-induced ground movements, the axial pile forces and the interface shear stresses. The ground settlements and the pile settlements were heavily affected by the face pressures and the positions of the pile tip with respect to the tunnel. When the piles were inside the tunnel influence zone, tensile forces were induced on piles, while compressive pile forces were expected to develop for piles that are outside the influence zone and on the boundary. In addition, the computed results have been compared with relevant previous studies that were reported in the literature. The behaviour of the piles that is triggered by adjacent tunnelling has been extensively examined and analysed by considering the several key features in substantial detail.

Experimental Study for Concrete Base to Sleeve connection of Hybrid Substructure for Offshore Wind Turbine (하이브리드 해상풍력발전 지지구조물의 콘크리트 베이스-슬리브 연결부에 대한 실험 연구)

  • Lee, Jeong-Hwa;Byun, Nam-Joo;Kim, Seong-Hwan;Park, Jae-Hyun;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.79-87
    • /
    • 2016
  • In this paper, concrete base to sleeve connections of hybrid substructures for offshore wind turbines were suggested and investigated experimentally. Punching shear strength tests with well-instrumented three connections under different reinforcement ratios and loading conditions were conducted to investigate the punching shear strength and the behavior of the concrete base to a sleeve connection. The test results showed that the punching strength and stiffness of the connections are affected mainly by the reinforcement ratios. The loading conditions with an axial load and proportional moment cannot affect the stiffness but affect the strength of the connections because of the axial load-moment interaction. The punching shear failure and critical section of the each test specimen are also discussed.