• 제목/요약/키워드: shear frame

검색결과 720건 처리시간 0.03초

Aspect ratios of code-designed steel plate shear walls for improved seismic performance

  • Verma, Abhishek;Sahoo, Dipti R.
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.107-121
    • /
    • 2022
  • Past studies have shown that the aspect ratio (width-to-height) of a steel plate shear wall (SPSW) can significantly affect its seismic response. SPSWs with lower aspect ratio (narrow SPSW) may experience low lateral stiffness and flexure dominated drift response. As the height of the frame increases, the narrow SPSWs prove to be uneconomical and demonstrate inferior seismic response than their wider counterparts. Moreover, the thicker web plates required for narrow SPSWs exerts high inward pull on the VBEs. The present study suggests the limiting values of the aspect ratio for an SPSW system by evaluating the seismic collapse performance of 3-, 6- and 9-story SPSW systems using FEMA P695 methodology. For this purpose, nonlinear models are developed. These models are validated with the past quasi-static experimental results. Non-linear static analyses and Incremental dynamic analyses are then carried. The results are then utilized to conservatively suggest the limiting values of aspect ratios for SPSW system. In addition to the conventional-SPSW (Conv-SPSW), the collapse performance of staggered-SPSW (S-SPSW) is also explored. Its performance is compared with the Conv-SPSW and the use of S-SPSW is suggested in the cases where SPSW with lower than recommended aspect ratio is desired.

Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel (L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석)

  • Yu, Sung-Yong;Ju, Ho-Seong;Ha, Soo-Kyoung
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

A Study on the Nonlinear Analysis of R/C Frames Structures subjected to Static Loads (철근콘크리트뼈대 구조물의 정적 비선형 해석에 관한 연구)

  • 심종성;조민수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.196-201
    • /
    • 1992
  • The purpose of this study is to develop the computer software for the nonlinear analysis of R/C frame structure under static loads. For this purpose, strain-rate dependant material model and physical element model considering both flexural and shear deformation are adopted and they are connected with 'TWO-D'which is commerical software for elastic structural analysis. The analytical results using the developed software are compared to the experiment results and they are generally satisfactory.

  • PDF

the Application and Structural Behavior of Ultra High Strength Concrete on Sam Sung Sin-Dae Bang project. (초고층 주상복합 건물에의 초고강도 콘크리트의 시공 및 구조적 성능)

  • 신성우;이광수;최종수;유석형;안종문;윤영수;성상래;백승준;이승훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.313-318
    • /
    • 1994
  • This paper present the application and Structural Behavior of Ultra-High Strength Concrete on Samsung Sin Dae-Bang Housing-Commercial Combined building with 28 story including 8 story basement in seoul. 70 MPa compressive strength has been placed for all 8 basement shear wall. 42 MPa design strength concrete was used for other basement and frame up to 10th floor which us used for commercial purposes

  • PDF

A Study on the Economical Design of Apartment House (경제적인 아파트 설계에 대한 연구)

  • 강문영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.378-384
    • /
    • 1995
  • This paper descrides on the economical design of apartment house. * The optimal problems are made by considering the objective function which minimize the construction cost of frame. * The object functions are taken as the codfficient equations of the cost function for a unit area. * Constraints are the design limits defined by the ultimate flexural strength, the ultimate shear strength. the minimum thickness, and the ratio of steel in accordance with ACI 318-89 Code. * Optimization is achieved by optimum nonlinear GINO(General interactive Optimizer)program. In design examples, it is compared with the optimum design results of apartment house and underground parking lot for structural systems.

  • PDF

A Study on Theoretical Analysis for Reinforced Concrete Transfer Girder of Hybrid Structures (복합구조의 철근콘크리트 전이보에 대한 이론적 해석 연구)

  • 권기혁;이춘호;김민수;이한선;고동우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.623-628
    • /
    • 2000
  • In this paper, the behavior for transfer girder of the upper-wall and lower-frame structures was studied by the nonlinear finite element analysis. It was analyzed and compared with the experimental results. Analysis results showed that failure modes were progressed by a initial diagonal crack in the shear span between the edges of the load and intermediate support plate. The nonlinear finite element analysis could predict deformation, principal stress, ultimate load and concrete crack. Also analysis results showed good agreement the test results.

  • PDF

Crack Modelling to Determine Concrete Contribution to Shear Resistance (콘크리트 전단 기여분 결정을 위한 균열묘사 방법)

  • 조순호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.872-877
    • /
    • 2003
  • The fixed-angle based modified compression field theory (MCFT) was developed to include the slip deformation across the crack, thereby allowing for the non-coincident directions of the principal strain and stress. To investigate the significance of crack modelling on the analysis, a series of tests on beams without transverse reinforcement was predicted by both rotating- and fixed-angle crack models within the frame of the MCFT. The results predicted by the fixed-angle MCFT were comparable to those by the rotating-angle MCFT when the initial crack angle of 45deg. and the related friction law are used.

  • PDF

Simplified Collapse Analysis of Ship Transverse Structures

  • Yang, Park-Dal-Chi
    • Selected Papers of The Society of Naval Architects of Korea
    • /
    • 제1권1호
    • /
    • pp.26-36
    • /
    • 1993
  • In this paper, a thoery for the static analysis of large plastic deformations of 3-dimentional frames, aiming at application to the collapse analysis of ship structures, is presented. In the frame analysis formulation, effects of shear deformations are included. A plastic hinge is inserted into the field of a beam and post-failure deformation of the plastic hinge is characterized by finite rotations and extensions. In order to model deep web frames of ship's structures into a framed structures, collapse of thin-walled plate girders is investigated. The proposed analysis method is applied to several ship structural models in the references.

  • PDF

Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate (매입형(슬림플로어) 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강 철골보-)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • 제16권2호통권69호
    • /
    • pp.235-245
    • /
    • 2004
  • The advantages of composite construction are now well understood in terms of structural economy, good performance in service, and ease of construction. However, these conventional composite construction systems have some problems in application to steel framed buildings due to their large depth. So, in this study we executed an experimental test with the "Slim Floor"system which could reduce the overall depth of composite beam. Slim Floor system is a method of steel frame multi-story building construction in which the structural depth of each floor is minimized by incorporating the steel floor beams within the depth of the concrete floor slab. Presented herein is an experimental study that focuses on the flexural behaviour of the partially connected slim floor system with asymmetric steel beams encased in composite concrete slabs. Eight full-scale specimens were constructed and tested in this study with different steel beam height, slab width, with or without shear connection and concrete topping thickness. Observations from experiments indicated that the degree of shear connection without additional shear connection was $0.53{\sim}0.95$ times that of the full shear connection due to inherent mechnical and chemical bond stress.

Effect of tip configuration of an oil fence on wake structure behind the fence (오일펜스의 tip 형상이 후류유동에 미치는 영향에 관한 연구)

  • Koh, Min-Seok;Lee, Sang-Joon;Lee, Choung-Mook;Chung, Sang-Kook
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.772-776
    • /
    • 2001
  • The flow structures of turbulent shear layer behind oil fences with different tip configurations were investigated experimentally using flow visualization and PIV velocity field measurement. An oil fence was installed in a circulating water channel and the flow structure around the fence tip was mainly analyzed in this experiment. The four tip configurations tested in this experiment are knife edge; semi-circle edge, circular edge and rectangular edge. The 300 instantaneous velocity fields were measured using the single-frame PIV system and they were ensemble averaged to give the mean velocity field and spatial distribution of turbulent statistics. Free stream velocity was fixed at 10ms/sec and the corresponding Reynolds number based on the fence height was Re=4000. As a result, for the oil fence with rectangular edge, the streamwise velocity component was decreased. On the other hand it was increased for the oil fence with circular edge. For all four fences tested in this study, general flow pattern of the lower shear layer is analogous but the upper layer shows difference depending on the tip configurations. The oil fence with circular edge has more diffusive upper shear layer than that of the others. The shear layer of the oil fence with rectangular edge has relatively thin thickness. The oil fence with circular edge was found to be proper shape for tandem fence.

  • PDF