• Title/Summary/Keyword: shear construction

Search Result 1,766, Processing Time 0.031 seconds

Shear-lag behavior of prestressed concrete box-girder bridges during balanced cantilever construction

  • Zhong, Xingu;Zhang, Tianyu;Shu, Xiaojuan;Xu, Hongliang
    • Advances in concrete construction
    • /
    • v.5 no.5
    • /
    • pp.469-479
    • /
    • 2017
  • Balanced cantilever construction is extensively used in the construction of prestressed concrete (PSC) box-girder bridges. Shear-lag effect is usually considered in finished bridges, while the cumulative shear-lag effect in bridges during balanced cantilever construction is considered only rarely. In this paper, based on the balanced cantilever construction sequences of large-span PSC box-girder bridges, the difference method is employed to analyze the cumulative shear-lag effect of box girders with varying depth under the concrete segments' own weight. During cantilever construction, no negative shear-lag effect is generated, and the cumulative shear-lag effect under the balanced construction procedure is greater than the instantaneous shear-lag effect in which the full dead weight is applied to the entire cantilever. Three cross-sections of Jianjiang Bridge were chosen for the experimental observation of shear-lag effect, and the experimental results are in keeping with the theoretical results of cumulative shear-lag effect. The research indicates that only calculating the instantaneous shear-lag effect is not sufficiently safe for practical engineering purposes.

Shear Resistance Performance of Vertical Construction Joints in Slurry Walls Using Concrete Shear Keys (콘크리트 전단키에 의한 지하연속벽 수직시공이음부의 전단저항 성능)

  • Lee, Jeong-Young;Kim, Seung-Weon;Kim, Doo-Kie
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.399-400
    • /
    • 2023
  • Current building structural standards require the shear strength and rigidity in the design of vertical construction joints in a slurry wall. This paper proposes a shear key resistance method for shear connection of vertical construction joints, and compares its structural performance with the currently prevalent method of shear friction rebar. The study found the structural performance of the shear key resistance method was significantly better than that of the shear friction rebar method.

  • PDF

Construction Method for Forming Concrete Shear Keys at Vertical Construction Joints of Slurry Walls (지하연속벽 수직시공이음부에 콘크리트 전단키를 형성하는 시공기술)

  • Lee, Jeong-Young;Kim, Seung-Weon;Kim, Doo-Kie
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.401-402
    • /
    • 2023
  • The shear connection of the vertical construction joint of a slurry wall by the concrete shear key has excellent structural performance and is economical and eco-friendly. However, technology for forming concrete shear keys in the underground is still underdeveloped. This paper proposes the development of the construction technology required to form a concrete shear key at the vertical construction joint of the slurry wall.

  • PDF

Force-Displacement Relationship Diagram for Shear Connections in Vertical Construction Joints of Slurry Walls (지하연속벽 수직시공이음부의 전단접합부에 대한 힘-변위 상관도)

  • Lee, Jeong-Young;Kim, Seung-Weon;Kim, Doo-Kie
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.397-398
    • /
    • 2023
  • To design the shear connections for vertical construction joints of slurry walls, it is necessary to create a force-displacement curve that represents the structural performance of the shear connections. This paper proposes a method for preparing the force-displacement curve of the shear connections including major considerations.

  • PDF

Mechanically fastened shear connectors in prefabricated concrete slabs - experimental analysis

  • Gluhovic, Nina;Markovic, Zlatko;Spremic, Milan;Pavlovic, Marko
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.369-381
    • /
    • 2020
  • Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen's layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.

Push-out Test on Welded Angle Shear Connectors used in Composite Beams (합성보에 적용된 앵글 전단연결재의 Push-out 실험)

  • Kim, Young Ju;Bae, Jae Hoon;Ahn, Tae Sang;Jang, Dong Woon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.155-167
    • /
    • 2014
  • Steel-concrete composite beam has been used for a considerable time in building construction. An essential component of a composite beam is the shear connection between the steel section and the concrete slabs, which is provided by mechanical shear connectors. A variety of shapes and devices have been in use as shear connectors. This study summarizes the results of an experimental investigation involving the testing of push-out specimens with angle shear connectors. All of 22 push-out specimens were designed to study the effect of a number of parameters on the shear capacity of angle shear connectors such as the height of the angle connector, the length of welding, and the pitch of angles. Based on the test results, a design equation was developed for predicting the shear strength of angle shear connectors.

Shear strength of reinforced concrete dapped-end beams

  • Lin, Ing-Jaung;Hwang, Shyh-Jiann;Lu, Wen-Yao;Tsai, Jiunn-Tyng
    • Structural Engineering and Mechanics
    • /
    • v.16 no.3
    • /
    • pp.275-294
    • /
    • 2003
  • In this study, 24 high-strength concrete dapped-end beams were tested to study the effects of the amount of main dapped-end reinforcement, the nominal shear span-to-depth ratio, and the concrete strength on the shear strength of dapped-end beams. Test results indicate that the shear strength of dapped ends increases with the increase in the amount of main dapped-end reinforcement and the concrete strength. The shear strength of dapped-end beam increases with the decrease of nominal shear span-to-depth ratio. A simplified method for determining the shear strength of reinforced concrete dapped ends is also proposed in this paper. The shear strengths predicted by the proposed method and the approach of PCI Design Handbook are compared with test results. The comparison shows that the proposed method can more accurately predict the shear strength of reinforced concrete dapped-end beams than the approach of PCI Design Handbook.

Study on the Shear Key-shaped Mold making Method utilizing 3D Printers (3D 프린터를 활용한 전단키 형상 몰드 제작 방법에 관한 연구)

  • Jang, Jong-Min;Jang, Hyeon-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.5-6
    • /
    • 2016
  • Due to the construction of high-rise and long axis etc, UHPC(Ultra High Performance Concrete) has attracted attention as a material that will replace the existing concrete. In order to improve the structural performance of each member joints, after demolding the concrete, method for surface treatment of the contact surface or by modifying the mold to create a shear key will be applied. In this study, to improve the conventional shear key manufacturing process, utilizing a 3d printer to produce a shear key plate. 3D printers have advantage it is inexpensively manufactured as compared with other production methods. Therefore, this study utilizes a 3D printer, we propose the shear key-shaped mold and plate shear key production measures.

  • PDF

An Assessment of Bonding Shear Performance of Ultra-high-performance Concrete Regarding Interface Treatment (표면처리방법에 따른 초고성능 콘크리트의 전단부착성능 평가 연구)

  • Jang, Hyun-O;Park, Jin-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.81-82
    • /
    • 2016
  • The present study aims to derive optimal interface treatment conditions for emulating a monolithic construction. The joints in this construction are formed through the bonding shear evaluation method during the placement of ultra-high-performance concrete (UHPC) and normal strength concrete (NSC). The evaluation items include push-off tests for homogeneous UHPC + UHPC and heterogeneous NSC + UHPC. The experimental samples comprised a monolithic placement as the baseline, two levels for the separated placement according to the compression strength of concrete, and five levels for the interface treatment. The increase in the number of grooves and their cross-sectional areas only slightly influenced the bonding shear performance. The optimal interface treatment method for the homogeneous UHPC + UHPC construction grooves was at least 30mm. The heterogeneous NSC + UHPC construction should utilize waterjet roughening to expose the aggregate for the increased roughness.

  • PDF

An Experimental Study on Lateral Load of Vertically Suspended Shear Reinforcement for Reinforced Concrete Flat Plate slab (철근콘크리트 무량판 슬래브의 수직걸림형 전단보강재의 수평하중에 대한 실험적 연구)

  • Woo, Jong-Yeol;Kim, Jae-Ung;Yoo, Choong-Geun;Kang, Su-Min;Lee, Byeong-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.78-79
    • /
    • 2014
  • This study is concerned with the VS shear reinforcement that it can be installed easily in filed as product at the factory and seismic performance can be achieved. The method of study is as follows. first, we researched constructability and economy of existing construction method. Secondly, we made specimen and were examined structural performance tests in order to verify the performance of the shear reinforcement for lateral force like seismic load. As a result, developed VS shear reinforcement increased in shear strength and stiffness of reinforcement, structural safety is judged to be increased.

  • PDF