• 제목/요약/키워드: shear bond strength test

검색결과 428건 처리시간 0.022초

샌드블라스팅 처리와 라이너가 지르코니아와 전장도재의 전단결합 강도에 미치는 영향 (Effect of sandblasting and liner on shear bond strength of veneering ceramic to zirconia)

  • 김기백;김재홍
    • 대한치과기공학회지
    • /
    • 제43권1호
    • /
    • pp.6-12
    • /
    • 2021
  • Purpose: This study aimed to compare the shear bond strength between zirconia cores and veneer ceramics as per the sand blasting and liner treatments. Methods: The following 4 groups of zirconia-veneering ceramic specimens were prepared: (1) Group I, untreated; (2) Group II, with 110 ㎛ aluminium oxide (Al2O3) sandblasting; (3) Group III, with liner (IPS e.max ZirLiner; Ivoclar Vivadent); and (4) Group IV, with 110 ㎛ Al2O3 sand blasting and liner. Surface roughness was measured for all the prepared specimens, and the surface morphology was observed using a scanning electron microscope. All the samples (n=40) were fixed with measuring jigs, and shear bond strengths were obtained using a universal testing machine with a crosshead speed of 0.5 mm/min. The shear bond strength data were analyzed using one-way analysis of variance and t-test. The post hoc comparison was performed using the Tukey's test (α=0.05). Results: A significant difference in the surface roughness was observed between the specimens of groups I and II (p<0.05). Surface treatment with liner and sandblasting showed higher shear bond strength between zirconia core and veneering ceramic (p<0.05). Conclusion: The sand blasting and liner treatment increased the shear bond strength between zirconia core and veneering ceramic.

네가지 상아질 접착제의 전단 결합 강도 비교 (COMPARISON OF SHEAR BOND STRENGTHS OF FOUR DENTINAL ADHESIVES)

  • 조경미;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.280-288
    • /
    • 1996
  • The purpose of this study was to assess comparatively the shear bond strength on dentin of four dentin bonding agents used in conjunction with light-curing composite resins. Clearfil New Bond, Scotchbond Multipurpose Dentin Adhesive, All-Bond 2 and X-R Bond were applicated on labial dentin surfaces just below dentin - enamel juction of bovine incisor teeth. After shear bond strength testing with the universal testing machine, the bonding interface of the specimens were observed under light stereomicroscope. Following results were obtained. 1. The shear bond strength was high in the order of B,C,D,A and group B Scotchbond Multipurpose Dentine Adhesive revealed greater bond strength than Clearfil New Bond and X-R Bond. (p<.001) 2. When using ANOVA and Duncan's multiple range test, there were statistical differences among the four groups, except between group Band C,group D and A. 3. There was no relationship between mode of failure and shear bond strength.

  • PDF

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

Comparative study of the shear bond strength of various veneering materials on grade II commercially pure titanium

  • Lee, Eun-Young;Jun, Sul-Gi;Wright, Robert F.;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.69-75
    • /
    • 2015
  • PURPOSE. To compare the shear bond strength of various veneering materials to grade II commercially pure titanium (CP-Ti). MATERIALS AND METHODS. Thirty specimens of CP-Ti disc with 9 mm diameter and 10 mm height were divided into three experimental groups. Each group was bonded to heat-polymerized acrylic resin (Lucitone 199), porcelain (Triceram), and indirect composite (Sinfony) with 7 mm diameter and 2 mm height. For the control group (n=10), Lucitone 199 were applied on type IV gold alloy castings. All samples were thermocycled for 5000 cycles in $5-55^{\circ}C$ water. The maximum shear bond strength (MPa) was measured with a Universal Testing Machine. After the shear bond strength test, the failure mode was assessed with an optic microscope and a scanning electron microscope. Statistical analysis was carried out with a Kruskal-Wallis Test and Mann-Whitney Test. RESULTS. The mean shear bond strength and standard deviations for experimental groups were as follows: Ti-Lucitone 199 ($12.11{\pm}4.44$ MPa); Ti-Triceram ($11.09{\pm}1.66$ MPa); Ti-Sinfony ($4.32{\pm}0.64$ MPa). All of these experimental groups showed lower shear bond strength than the control group ($16.14{\pm}1.89$ MPa). However, there was no statistically significant difference between the Ti-Lucitone 199 group and the control group, and the Ti-Lucitone 199 group and the Ti-Triceram group. Most of the failure patterns in all experimental groups were adhesive failures. CONCLUSION. The shear bond strength of veneering materials such as heat-polymerized acrylic resin, porcelain, and indirect composite to CP-Ti was compatible to that of heatpolymerized acrylic resin to cast gold alloy.

One-bottle 상아질 접착제의 전단결합강도와 접착성에 관한 부식시간의 효과 (THE EFFECT OF ETCHING TIME ON SHEAR BOND STRENGTH AND ADAPTIBILITY OF ONE-BOTTLE DENTIN ADHESIVE)

  • 박광수;박일윤;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.240-250
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of different etching time on the shear bond strength and adaptibility of composite to enamel and dentin when used one-bottle adhesive Prime & Bond$^{TM}$ 2.0. The proximal and occlusal surfaces of 88 extracted human molars were ground to expose enamel(n=44) and dentin (=44) using diamond wheel saw. Teeth were randomly assigned to four test groups(n=11) and received the following treatments : Control group were conditioned with 36% phosphoric acid for 20 sec. according to the manufacturer's directions. Experimental 10 sec. group, 30 sec. group and 60 sec. group were conditioned with 36% phosphoric acid for 10 sec., 30 sec. and 60 sec., respectively. Teeth were rinsed and dried for 2 sec. Prime & Bond$^{TM}$ 2.0 were applied according to the manufacturer's directions and Spectrum$^{TM}$ TPH composite resins were bonded to enamel and dentin surfaces. All specimens were stored in distilled water for 24 hours. Eighty specimens were sheared in a Universal Testing Machine with a crosshead speed of 5mm/minute. One way ANOVA and LSD test were used for statistical analysis of the data. Failure modes of all specimens after shear bond strength test were examined and listed. Also, representive postfracture modes and eight specimens were examined under scanning electron microscope. The results of this study were as follows: 1. The shear bond strength to enamel was the highest value in 30 sec. group (20.68${\pm}$8.54MPa) and the lowest value in 10 sec. group (14.92${\pm}$6.07MPa), so there was significant difference of shear bond strength between two groups (p<0.05). But there was no significant difference among other groups (p>0.05). With longer etching time to enamel from 10 sec. to 30 sec., higher the shear bond strength was obtained, but the shear bond strength was decreased at 60 sec. etching time. 2. The shear bond strength to dentin was the highest value in control group (13.08${\pm}$6.25MPa) and the lowest value in 60 sec. group (9.47${\pm}$3.35MPa), but there was no significant difference among the all groups (p>0.05). The eching time over 20 sec. decreased the shear bond strength to dentin. 3. In SEM observation, the enamel and resin interfaces were showed close adaptation with no relation to etching time of enamel. And the dentin and resin interfaces were showed close adaptation at 20 sec. and 30 sec. etching time, but showed some gaps at 10 sec. and 60 sec. etching time. Accordingly, these results indicated that a appropriate etching time in Prime & Bond$^{TM}$ 2.0 was required to be 30 sec. in enamel and 20 sec. in dentin for the high shear bond strength and good adaptation between the composite resin and tooth substance.

  • PDF

Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer

  • Koodaryan, Roodabeh;Hafezeqoran, Ali
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.504-510
    • /
    • 2016
  • PURPOSE. Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. MATERIALS AND METHODS. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (${\alpha}=.05$). RESULTS. The bond strength values of A and S were significantly higher than those of N (P<.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG (P<.001). CONCLUSION. The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

상아질의 경도, 위치 및 잔존 상아질 후경이 상아질에 대한 부위별 미세 전단결합강도에 미치는 영향 (REGIONAL MICRO-SHEAR BOND STRENGTH TO DENTIN:EFFECTS OF DENTINAL HARDNESS, POSITION, AND REMAINING DENTIN THICKNESS)

  • 황선성;임미경;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.401-412
    • /
    • 1998
  • The aim of this study was to measure the regional micro-shear bond strength of dentin bonding agents to dentin, and to investigate the relationship between the micro-shear bond strength and two dentinal characteristics ; Vickers hardness and remaining dentin thickness. Twenty-four freshly extracted, noncarious human molars were selected for this study. The materials tested in this study consisted of two commercially available dentin bonding agents (MAC-BOND, ONE-STEP) and two restorative light-cured composite resins (AELITEFIL, Z100). The occlusal or side surface of tooth crown was sectioned to expose dentin, and the exposed surface was finally polished with # 600 sandpaper. Four groups of application methods were used combining the filling materials and the dentin bonding agents. The composite resin-attached tooth specimens were embeded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of 1mm $\times$ 1mm. Nine specimens were obtained from each tooth. The cut specimens were divided into three groups depending on the position of the dentin bonding surface. The micro-shear bond strength, remaining dentin thickness, and dentinal hardness were measured. Experimental results were then statistically analyzed with ANOVA. t-test, Scheffe test, and regression analysis. From this experiment, the following results were obtained : 1. In the case of occlusal surface bonding, the pooled micro-shear bond strength of ONST-AELIT group (16.62 MPa) was significantly higher than that of MACB-AELIT group (9.91 MPa) (p<0.05). However, there was no significant difference in the micro-shear bond strength depending on the dentin position (p>0.05). 2. In the case of side surface bonding of crown, the pooled micro-shear bond strength of four different bonding groups was not significantly different among each other (p>0.05). However, in three of the test groups (ONST-AELIT, MACB-Z100, ONST-Z100), the micro-shear bond strength to the lower 1/3(III) position was significantly lower than that to middle 1/3(II) position of surface (p<0.05). 3. In the ONST-AELIT bonding group, the pooled micro-shear bond strength to the occlusal surface was significantly lower than that to the side surface of crown (p<0.05). 4. There was no significant correlation between the micro-shear bond strength and dentin hardness / remaining dentin thickness (p>0.05).

  • PDF

동결토 전단강도를 활용한 동착강도 산정에 관한 연구 (A Study for Predicting Adfreeze Bond Strength from Shear Strength of Frozen Soil)

  • 최창호;고성규
    • 한국지반공학회논문집
    • /
    • 제27권10호
    • /
    • pp.13-23
    • /
    • 2011
  • 동토기반 말뚝기초의 지지력은 말뚝구조물 표면과 주변 토사의 접촉면에서 발현되는 동착강도에 의해 산정되며, 이는 동착-강도가 동토지반 기초설계를 위한 가장 주요한 설계정수임을 의미한다. 동착강도는 토사종류, 동결온도, 말뚝표면에 수직방향으로 작용하는 지중응력, 재하속도, 말뚝구조물의 표면 거칠기 등 다양한 인자들에 동시다발적인 영향을 받는 것으로 보고되고 있다. 1960년대부터 동토지반 기초설계를 위한 동착강도 산정방법들이 제안되어 왔으나, 대부분 동결온도와 말뚝구조물 표면특성에 대한 영향은 고려하고 있는 반면 동착강도의 주요 영향인자 중 하나인 지중응력에 의한 영향을 고려하지 않고 있어 소정깊이 이상의 말뚝기초 설계를 위한 동착강도 산정방법으로 활용되기에는 한계가 있는 것으로 판단된다. 본 연구에서는 동결온도뿐 아니라 지중응력이 동착강도에 미치는 영향을 파악하기 위하여 직접전단시험기를 활용한 동결토 전단강도 및 동착강도 측정실험을 각각 수행하였다. 실험결과 전단강도와 동착강도는 모두 동결온도 조건이 낮아질수록, 혹은 수직응력 조건이 커질수록 증가하는 경향을 보였다. 전단강도와 동착강도의 정량적 관계분석을 위해 정의된 전단강도와 동착강도의 비 $r_s$는 초기 동결온도에서는 급격하게 감소하는 경향을 나타냈으나, 동결온도가 낮아질수록 증가하며 수렴구간을 형성해가는 경향을 보였다. 본 연구에서는 최종적인 연구결과로서 동결온도 및 수직응력 조건을 바탕으로 결정된 $r_s$값을 이용하여 동결토의 전단강도로부터 동착강도를 예측할 수 있는 방법을 제안하고 있다.

불소가 유리되는 교정용 전색제가 광중합형 및 화학중합형 교정용 접착제의 전단결합강도에 미치는 영향 (THE EFFECTS OF FLUORIDE RELEASING ORTHODONTIC SEALANT ON THE SHEAR BOND STRENGTH Of LIGHT-AND CHEMICAL-CURED ORTHODONTIC RESINS)

  • 김봉현;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제27권5호
    • /
    • pp.781-789
    • /
    • 1997
  • 본 연구는 교정치료를 위해 최근에 발거된 소구치 65개를 대상으로 발거직후 부착된 이물질을 제거하고 생리식염수에 담구어 보관한 후 법랑질을 퍼미스 및 $38\%$ 인산으로 표면 처리하고 불소가 유리되는 교정용 전색제로는 광중합형 FluoroBond, 광중합 접착제로는 Transbond, 화학중합 접착제로는 Mono-Lok 2를 선정하여 1차 부착 및 재부착시의 전단결합강도를 만능강도시험기로 측정함으로서, 치아우식 예방 및 진행 억제효과를 지닌 불소가 유리되는 교정용 전색제가 광중합형 및 화학중합형 교정용 접착제의 전단결합강도에 미치는 영향과 재부착에 의한 전단결합강도의 변화를 규명하고, 광중합형 접착제와 화학중합형 접착제 사이의 전단결합강도를 비교하여 다음의 결론을 얻었다. 1. 1차부착에 의한 전단결합강도의 크기는 Mono-Lok2군(11.84MPa), Trans bond군(10.75MPa), Light cured FluoroBond+Mono-Lok 2군(9.69MPa), Light cured FluoroBond+Transbond군(9.39MPa)순이었다. 2. 재부착에 의한 전단결합강도의 크기는 Transbond군(7.40MPa), Light cured FluoroBond+Transbond군(6.48MPa), Mono-Lok 2군(5.89MPa), Light cured FluoroBond+Mono-Lok 2군(5.15MPa)순이었다. 3. 불소가 유리되는 교정용 전색제를 적용한군과 적용하지 않은 군 모두에서 화학중합형 접착제가 광중합형 접착제보다 높은 전단결합강도를 보였으나 통계학적으로 유의한 차이는 없었다(p>0.05). 4. 불소가 유리되는 교정용 전색제를 적용한군과 적용하지 않은 군 모두에서 재부착된 광중합형 접착제가 재부착된 화학중합형 접착제보다 높은 전단결합강도를 보였으나 통계학적으로 유의한 차이는없었다(p>0.05). 5. 1차 부착된 군에 비해 재부착된 모든 군에서 전단결합강도가 현저하게 감소되었으며, 통계학적으로 유의한 차이를 보였다(p<0.05 p<0.001). 이상의 결론을 종합해볼 때 임상적으로 브라켓의 전단결합강도에 경향을 미치지 않는 불소가 유리되는 교정용 전색제를 치아 협면에 적용하여 불소의 유리에 의한 치아우식 예방 및 억제효과를 기대하는 것이 필요할 것으로 생각된다.

  • PDF

직접 전단 실험을 통한 배수성포장용 택코트 특성 평가 (Evaluation of Characteristics of Tack Coat for Porous Pavement using Direct Shear Test)

  • 김낙석;홍은철;조신행
    • 한국방재학회 논문집
    • /
    • 제9권1호
    • /
    • pp.27-32
    • /
    • 2009
  • 본 연구의 주목적은 아스팔트 포장층간의 접착전단강도를 측정하는 실험법과 평가 방법을 개발하고 배수성 포장에 사용되는 택코트 재료의 특성과 적정 살포량을 평가하고자 하였다. 실험에는 두 종류(RSC-4, 개질유화)의 유화아스팔트와 가열 아스팔트바인더 타입(HM-1) 한 종류로 실시하였으며, HM-1은 배수성 포장에 사용하기 위해 새로 개발된 제품이다. 접착전단강도를 측정하기 위해 직접전단실험을 다양한 실험 조건에서 수행하였다. 실험을 통해 얻은 접착전단강도 값은 결과의 변별력이 떨어 졌으며 하중-변위 곡선의 면적인 터프니스가 접착전단강도를 평가하는데 보다 유용한 것을 확인 할 수 있었다. 배수성 포장의 경우 RSC-4의 경우는 $0.8l/m^2$ 이상, 개질유화아스팔트의 경우는 $0.5{\sim}0.6l/m^2$의 살포량이 적당한 것으로 나타났다. Trackless 성능이 우수한 HM-1은 유화 아스팔트 택코트에 비해 월등히 좋은 접착전단성능을 발휘하는 것으로 나타났다.