• Title/Summary/Keyword: shape retention

Search Result 93, Processing Time 0.027 seconds

Changes of Shape retention and Total Appearance Value(TAV) After Fusing (접착포의 형태 보형성(shape retention)과 TAV(Total Appearance Value)의 변화)

  • 지주원;유효선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1015-1024
    • /
    • 2000
  • The purpose of this study is 1) to analyse the bending property of the fused fabric and each component of the fused fabrics. 2) to examine the effect of fusing temperature on the bending property of the fused interlining and fused fabrics. 3) to examine the changes of B/W, 2HB/W and TAV of the fused fabrics according to the types of face fabric, interlining, fusing temperature. Five types of wool fabric, four types of shingosen fabric and four types of interlining were used for this study. The fusing condition in this study were the three types of fusing temperature of 10$0^{\circ}C$, 12$0^{\circ}C$, 14$0^{\circ}C$, the pressure of 4 kgㆍf/$cm^2$, and pressing time of 12 seconds. The results obtained from this study were as follows. 1) The bending rigidities and hysteresis of fabrics after fusing were increased. The bending behavior of fused fabrics were governed by the bending behavior of face fabric and interlinings and $\alpha$$_{B}$ values. 2) The KES standardized basic values of B/W and 2HB/W were increased after fusing. The B/Ws of fused fabrics were mainly determined by the $\alpha$$_{B}$ values of interlinings. The 2HB/Ws of fused fabrics seemed to be controlled by the fusing temperature. 3) The changes of TAVs of wool fused fabrics differed from those of shingosen fused fabrics. As the $\alpha$$_{B}$ values of fabric were larger and fusing temperature were increased, the TAVs of wool fused fabrics were smaller though those of shingosen fused fabrics were larger. 4) The TAVs of fused fabrics were highly correlated with the B/Ws of fused fabrics. In the case of wool fused fabrics, the TAVs of fused fabrics were negativly correlated with the 2HB/Ws of wool fabrics and used interlinings.nings.

  • PDF

Effect of Heat Treatment on Properties of Tungsten Embolization Coils (텅스텐 색전코일의 특성에 미치는 열처리 효과)

  • Son, Ung-Hui;Hong, Sun-Hyeong;Sin, Gyeong-Min;Lee, Yun-Sin;Park, Jae-Hyeong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.333-339
    • /
    • 1998
  • The effect of heat treatment conditions on the properties of tungsten(W) embolization coils has been evaluated. The W embolization coils were fabricated by coiling the primary W coil with a diameter of 30.mm on a alumina rod mandrel with a diameter of 2.92mm. The secondary coils were then heat treated at 475$^{\circ}C$and 600$^{\circ}C$ for various heat treatment time ranging from 5 minutes to 36hours. The pitch distance, diameter and shape retention capability of the W embolization coils were characterized after the heat treatment. The pitch distance of the W embolization coils increased with the heat treatment time. The diameter of W emboliazation coils decreased continuously with heat treatment time. The shape retention capability of the W embolization coils increased with the heat treatment time due to an increase in elasticity by formation of tungsten oxide film on W coil surface during the heat treatment. The heat treatment condition of W embolization Col at 600$^{\circ}C$ for 20 minute was considered desirable based on the optimization of the shape retention capability, pitch distance and secondary coil diameter after heat treatment.

  • PDF

A COMPARATIVE OF RETENTIVE FORCE OF VARIOUS OVERDENTURES USING SEVERAL MAGNETS (수종의 Magnet를 이용한 Overdenture의 유지력에 관한 비교연구)

  • Hur, Kyoung-Sook;Hur, Song-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.49-57
    • /
    • 1991
  • The magnets were widely used to increase the retention of overdentures. The purpose of this study was to compare the break load between overdentures and edentulous models. For this study, Model former(U-402) was used for model fabrication and four different magnets were used for evaluation of break load. The artificial saliva was used between overdenture and model. Breakaway loads were tested with an Instron 1122 at a speed of 2mm/min. The results were as follows. 1. The retentivee forces complete dentures with artificial saliva were than the retentive forces of complete detures without artificial saliva. 2. Magnetic overdenture with artificial saliva showed best retentive force, magnetic overdenture without artificial saliva showed the next retentive force, and the complete denture without artificial saliva showed the worst retention. 3. As the magnetic sizes increased, the retentive forces of magnetics were increased. 4. The retentive force of nipple shape magnet is greater than the retentive force of flate shape magnet in the same size.

  • PDF

Chiral Separation of Ibuprofen by Supercritical Fluid Chromatography (초임계유체 크로마토그래피를 이용한 Ibuprofen의 키랄분리)

  • 한순구;노경호
    • KSBB Journal
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • The separation method using chiral stationary phase in preparation of chiral compound was wildly used, but in this work, supercritical fluid chromatography was suggested in the stability to resolve the chiral mixtures. To determine the optimum operating condition of the racemic ibuprofen, the retention factor and resolution with change in pressures, temperatures and the contents of IPA % (vol.) in CO$_2$ were investigated. The retention factor was decreased with increase in pressure and decrease in temperature. The factor was also influenced by the content of IPA in mobile phase, while the resolution was worse with a increase in IPA %. From the experimental results, the desirable separation condition was 130 bar, 311.15 K and 4% IPA in CO$_2$. Compared to the asymmetric peak shape by liquid chromatography, that of supercritical fluid chromatography was symmetric which was a favorable condition for preparative separation.

Improvements in the Physical Properties of Hanji by Using Red Algae Pulp

  • Seo, Yung-Bum;Kim, Young-Wook;Lee, Min-Woo;Jung, Sun-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.5
    • /
    • pp.33-37
    • /
    • 2009
  • Hanji is a traditional Korean handmade paper, made of bast fibers of the paper mulberry. Its fiber furnish is much more expensive than wood fiber furnish. Hanji with a low basis weight requires additional opacity and smoothness for better writing and printing. Filler such as calcium carbonate can not be used to raise the opacity of Hanji because of its low retention in low basis weight paper and the high freeness of the Hanji fiber furnish. Addition of red algae pulp, which is prepared from marine red algae to the Hanji fiber furnish negated retention problems happening in the case of mineral filler addition, and produced a substantial improvement in the opacity and smoothness of Hanji. The higher retention was due to the much larger size of the red algae fibers compared to the mineral fillers. The improvement in opacity and smoothness were also due to the shape of the red algae fibers: that red algae fibers are narrower in widths and shorter in lengths than wood fibers results in increased surface area and smoothness.

Problem-solving approach for salbutamol analysis by HPLC during pharmaceutical assay

  • Gholizadeh-Hashjin, Aiesheh;Hamishehkar, Hamed;Monajjemzadeh, Farnaz
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.189-196
    • /
    • 2022
  • When cationic basic compounds are chromatographed using hydro-organic mobile phase, the presence of anionic free silanols in the silica-based stationary phases results in broad and asymmetrical peaks. The addition of an ionic reagent to the mobile phase prevents analytes from accessing free silanols, improving peak shape. In this study, the chromatographic behavior of salbutamol sulfate as a basic compound was investigated under various conditions, including the use of different columns, mobile phases, and ion-pair reagents such as triethanolamine (TEA) and sodium heptane sulfonate (SHS). The retention and peak shape of chromatograms were both evaluated. The results show that pre-conditioning the column with TEA and including it in the mobile phase can prevent cationic analytes from accessing anionic silanols, resulting in improved peak shape. Furthermore, buffering the mobile phase is an important factor in keeping the pH constant throughout the process. The chosen method was validated in part. This study could be helpful for researchers and analyst to solve such problems with cationic basic components.

The Behavior of Retention Wall By 3-D Finite Element Method (3차원 유한요소해석에 의한 흙막이 벽체의 거동특성)

  • 이진구;장서만;전성곤;이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.347-354
    • /
    • 2001
  • In this study, 3-D FEM analysis are carried out to investigate the effect of the corners and re-entrant corners which can't be analysed by 2-D analysis. The excavation shape is re-entrant type conditions. The wall displacement, earth pressure and effectiveness of the corner struts are investigated in the re-entrant case, The 3D analysis are peformed to evaluate the effect of various factors, such as re-entrant corner size, excavation depth, and presence of struts. The wall displacement and earth pressures are influenced the size of re-entrant corner. Therefore, the effect of re-entrant corner should be considered in the evaluation of the earth pressure and displacement of the corners. Finally, strut-support systems are not effective at the re-entrant corner.

  • PDF

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

Occlusal and Periodontal Status of Teeth with Non-carious Cervical lesions (비우식성 치경부병소를 가진 구치부 치아의 교합 및 치주상태에 관한 연구)

  • Son, Min-Ook;Seo, Sung-Chan;Jeong, Dong-Keun;Lee, Eun-Suk;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.647-657
    • /
    • 2004
  • A non-carious cervical lesion(NCCL) is the loss of tooth structure at the cementoenamel junction level that is unrelated to dental caries. This study was to evaluate the occlusal and periodontal status of teeth with non-carious cervical lesions. We evaluated 105 teeth with non-carious cervical lesions in 35 subjects aged 38-75 years and characterized them based on the shape and dimension, plaque retention, bleeding on probing(BOP), probing pocket depth(PPD), occlusal status, brushing type, hypersensitivity and wear facet. The results of this study were as follows 1. No significant association was observed between cervical lesions and occlusal contact in lateral excursions. 2. No significant difference occurred in plaque retention, PPD, BOP between teeth with and without cervical lesions. 3. Test teeth had a significantly higher percentage of hypersensitivity and occlusal wear facet than teeth without cervical lesions. 4. Wedge shaped lesions had a significantly higher percentage of plaque than saucer shaped lesions. 5. Teeth with plaque were found to have significantly deeper PPD than teeth without plaque retention in cervical regions. 6. Teeth with occlusal contacts were found to have significantly deeper PPD than teeth without occlusal contacts. 7. No significant association was observed between cervical lesions and PPD independent of plaque retention and occlusal contacts Although more knowledge is necessary, our results suggest that occlusal contact and bacterial plaque may influence on periodontal tissue, but NCCL is not directly associated with periodontal health

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report (CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례)

  • Lee, Han-na;Shim, Ji-Suk;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.374-381
    • /
    • 2022
  • This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.