• 제목/요약/키워드: shape of electrodes

검색결과 196건 처리시간 0.032초

심전도와 심음을 측정하기 위한 무선 전자 심전도-심음 청진기 개발 (Development of Wireless Electronic Cardiogram and Stethoscope (ECGS) to Measure ECG Signal and Heart Sound)

  • 조한석;강영환;박재순;최진규;정연호;구치완
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권2호
    • /
    • pp.124-130
    • /
    • 2022
  • In this paper, we proposed a portable electronic cardiogram and stethoscope (ECGS) that can simultaneously perform the electrocardiogram (ECG) and auscultation tests to increase the reliability of diagnosis of heart disease. To measure the ECG and heart sound (HS) at the same time, three ECG electrodes and a microphone sensor were combined into a triangular shape with a width of 90 mm and a height of 97 mm that can be held in one hand. In order to prevent skin problems when they contact the patient's skin, a capacitive coupled electrode was selected as the ECG electrode and a silicone material was used in a chest piece with the microphone sensor. For the signals measured from the electrodes and the chest piece, filters were respectively configured to pass only the signals of 0.01-100 Hz and 20-250 Hz, which are frequency bands for ECG and HS. The filtered ECG and HS analog signals were converted into digital signals and transmitted to a PC using wireless communication for monitoring them. The HS could be auscultated simultaneously using an earphone. The monitored ECG had an SNR of about 34 dB and a P-QRS-T waveform is clearly visible. In addition, the HS had an SNR of about 28 dB and both S1 and S2 are clearly visible. It is expected that it can aid doctors' inexperience in analyzing the ECG and HS.

PNN-PZT 세라믹스의 저온 소결 및 전기적 특성 평가 (Low Temperature Sintering of PNN-PZT Ceramics and Its Electrical Properties)

  • 이명우;김성진;윤만순;류성림;권순용
    • 한국전기전자재료학회논문지
    • /
    • 제21권12호
    • /
    • pp.1077-1082
    • /
    • 2008
  • To fabricate a multi-layered piezoelectrics/electrodes structure, the piezoelectrics should be sintered at the temperature lower than $950^{\circ}C$ to use the silver electrode, which is cheaper than the electrodes containing noble metals such as Pd and Pt. Therefore, in this study, we modified the composition of $Pb(Zr,Ti)O_3$-based material as $(Pb_{0.98}Cd_{0.02})(Ni_{1/3}Nb_{2/3})_{0.25}Zr_{0.35}Ti_{0.4}O_3$ to lower the sintering temperature and to improve the piezoelectric properties. Small amount of $MnCO_3$, $SiO_2$, and $Pb_3O_4$ were also added to lower the sintering temperature of the ceramic. The prepared raw powders were mixed by using a ball mill for 24 hours. And then the mixed powders were calcinated for 2 hours at $800^{\circ}C$. The calcinated powders were again crushed with the ball mill for 72 hours. The final powders were pressed for making the shape of ${\emptyset}15\;mm$ disk. The disk-type samples were sintered at temperature range of $850{\sim}950^{\circ}C$. The crystal phases of the sintered specimens were perovskite structure without secondary phases. All of the measured electrical properties such as electromechanical coupling coefficients ($k_p$), mechanical quality factors ($Q_m$), and piezoelectric charge constants ($d_{33}$) were decreased with decreasing the sintering temperatures. The electrical properties measured at the sample sintered at $950^{\circ}C$ were 54% of $k_p$, 503 of $Q_m$, and 390 pC/N of $d_{33}$, respectively. These properties were considered to be fairly good for the application of multi-layered piezoelectric generators or actuators.

환상형상 전극구조를 갖는 저압 RF plasma를 이용한 CF4 제거 (Abatement of CF4 Using RF Plasma with Annular Shape Electrodes Operating at Low Pressure)

  • 이재옥;허민;김관태;이대훈;송영훈;이상윤;노명근
    • 한국대기환경학회지
    • /
    • 제26권6호
    • /
    • pp.690-696
    • /
    • 2010
  • Abatement of perfluorocompounds (PFCs) used in semiconductor and display industries has received an attention due to the increasingly stricter regulation on their emission. In order to meet this circumstance, we have developed a radio frequency (RF) driven plasma reactor with multiple annular shaped electrodes, characterized by an easy installment between a processing chamber and a vacuum pump. Abatement experiment has been performed with respect to $CF_4$, a representative PFCs widely used in the plasma etching process, by varying the power, $CF_4$ and $O_2$ flow rates, $CF_4$ concentration, and pressure. The influence of these variables on the $CF_4$ abatement was analyzed and discussed in terms of the destruction & removal efficiency (DRE), measured with a Fourier transform infrared (FTIR) spectrometer. The results revealed that DRE was enhanced with the increase in the discharge power and pressure, but dropped with the $CF_4$ flow rate and concentration. The addition of small quantity of $O_2$ lead to the improvement of DRE, which, however, leveled off and then decreased with $O_2$ flow rate.

회전구동 정전형 마이크로 액추에이터를 이용한 고트랙밀도 HDD용 이단 구동 시스템 (Dual Stage Actuator System for High Density Magnetic Disk Drives Using a Rotary-type Electrostatic Microatuator)

  • 정성환;최재준;박지황;이창호;김철순;민동기;김영훈;이승희;전종업
    • 한국정밀공학회지
    • /
    • 제22권10호
    • /
    • pp.174-185
    • /
    • 2005
  • This paper presents the design, fabrication, and testing results of a dual stage actuator system for a fine positioning of magnetic heads in magnetic disk drives. A novel rotary microactuator which is electrostatically driven and utilized as a secondary actuator was designed. The stator and rotor electrodes in the microactuator was revised to have the optimal shapes and hence produces much higher rotational torque compared with the conventional comb-shape electrodes. The microactuators were successfully fabricated using SoG(silicon on glass) processing technology, which is known as being cost-effective. The fabricated microactuator has the structural thickness of $45{\mu}m$ with the gap width of approximately $3{\mu}m$. The dynamic characteristic of microactuator/slider assembly was investigated, and its natural frequency and DC gain were measured to be 3.4kHz and 32nm/V, respectively. The microactuator/slider assembly was integrated into a HDD model V10 of Samsung Electronics Co. and a dual servo algorithm was tested to explore the tracking performance of dual stage actuator system where the LDV signals instead of magnetic head signals were used. Experimental results indicate that this system achieves the tracking accuracy of 30nm. This value corresponds to a track density of 85,000 track per inch(TPI), which is about 3 times greater than that of current hard disk drives.

전처리를 이용한 탄소 나노 섬유의 균일한 SnO2 코팅막 형성 (Formation of Uniform SnO2 Coating Layer on Carbon Nanofiber by Pretreatment in Atomic Layer Deposition)

  • 김동하;류도형;최병준
    • 한국분말재료학회지
    • /
    • 제25권1호
    • /
    • pp.43-47
    • /
    • 2018
  • Carbon nanofibers (CNF) are widely used as active agents for electrodes in Li-ion secondary battery cells, supercapacitors, and fuel cells. Nanoscale coatings on CNF electrodes can increase the output and lifespan of battery devices. Atomic layer deposition (ALD) can control the coating thickness at the nanoscale regardless of the shape, suitable for coating CNFs. However, because the CNF surface comprises stable C-C bonds, initiating homogeneous nuclear formation is difficult because of the lack of initial nucleation sites. This study introduces uniform nucleation site formation on CNF surfaces to promote a uniform $SnO_2$ layer. We pretreat the CNF surface by introducing $H_2O$ or $Al_2O_3$ (trimethylaluminum + $H_2O$) before the $SnO_2$ ALD process to form active sites on the CNF surface. Transmission electron microscopy and energy-dispersive spectroscopy both identify the $SnO_2$ layer morphology on the CNF. The $Al_2O_3$-pretreated sample shows a uniform $SnO_2$ layer, while island-type $SnO_x$ layers grow sparsely on the $H_2O$-pretreated or untreated CNF.

전도성 다공성 구조 압력감지소자 (Pressure Sensitive Device Using Conductive and Porous Structures)

  • 소혜미;박철민;장원석
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.601-605
    • /
    • 2014
  • 일반적으로 표면적/부피비가 큰 전도성 다공체는 수퍼캐패시터의 전극이나 흡수제, 유연히터 등의 다양한 분야에 적용되어 왔다. 본 논문에서는 이러한 전도성 다공성 구조의 역학적 전기적 특성을 이용하여 고감도 압력센서를 구현하였다. 탄소나노튜브 용액에 스펀지를 적셔 다공체에 전도성을 부여하였으며, 압력에 따른 전도성 다공체의 저항 변화를 측정하였다. 전도성 스펀지에 압력이 가해졌을때, 각각의 탄소나노튜브들은 서로 맞붙게 되어 저항이 최대 20%까지 줄어듦을 확인하였다. 부드럽고 탄성력이 뛰어난 탄소나노튜브 스폰지는 반복적인 압축실험에도 모양의 변형 없이 매우 빠르게 안정화되고 일정한 저항변화를 확인할 수 있었다. 또한 스펀지 압력소자를 유연소자에 적용하기 위하여 탄소나노튜브 트랜지스터와 연결하여 외부압력에 따른 전기적 특성변화를 측정하였다.

직류 전류 이용 종양세포치료의 특성 연구 (Characterization Analyses for Direct Current Tumor Ablation)

  • 양태건;김재홍
    • 한국진공학회지
    • /
    • 제20권4호
    • /
    • pp.307-312
    • /
    • 2011
  • 정상 세포로부터 암과 같은 종양세포를 제거하는 방법으로 라디오주파수의 전자파를 이용하여 세포가 사멸되는 임계온도보다 높은 온도로 국소 가열하는 발열 치료법이 임상에서 시술되고 있다. 그러나 이 기술은 임상에서 활발히 사용되기에는 여러 가지 제약 요인이 존재한다. 본 연구에서는 교류파 대신에 미소 직류전원을 사용하여 국소부위에 열을 발생하는 안전성이 증가된 방법의 실효성을 이론적으로 입증하고자 한다. 종양세포의 형태에 따라 적당한 모양의 전극을 종양조직에 삽입하고 종양조직의 형태와 유사한 열분포를 갖도록 제어하는 기술을 개발한다. 열원은 조직 내에 삽입된 전극과 매질에 형성되는 전기장에 의한 저항열이다. 종양 조직 내에 삽입된 전극에 10 V, 20 V, 30 V를 각각 인가하고 시간에 따른 열분포를 전산모의 하였다. 결과적으로, 20 V를 전극에 인가하면 1~2 분 이내에 버섯모양의 등온도 분포를 갖으며 세포를 고사시키는 온도 이상의 치료영역이 형성됨을 보였다. 4개의 전극에 대칭적인 전위를 인가하고 $50^{\circ}C$ 이상의 온도 분포를 암 조직의 모양과 유사하게 분포하도록 조절하여 효과적인 치료를 수행 할 수 있는 가능성을 제시하고자 한다.

PdCu를 전기 도금한 레이저 유도 그래핀 전극 기반의 과산화수소 측정 센서 개발 (Development of a Hydrogen Peroxide Sensor Based on Palladium and Copper Electroplated Laser Induced Graphene Electrode)

  • 박대한;한지훈;김태헌;박정호
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1626-1632
    • /
    • 2018
  • In this paper, we describe the fabrication and characterization of a hydrogen peroxide ($H_2O_2$) sensor based on palladium and copper (PdCu) electroplated laser induced graphene (LIG) electrodes. $CO_2$ laser was used to form LIG electrodes on a PI film. This fabrication method allows simple control of the LIG electrode size and shape. The PdCu was electrochemically deposited on the LIG electrodes to improve the electrocatalytic reaction with $H_2O_2$. The electrochemical performance of this sensor was evaluated in terms of selectivity, sensitivity, and linearity. The physical characterization of this sensor was conducted using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), which confirmed that PdCu was formed on the laser induced graphene electrode. In order to increase the sensor sensitivity, the Pd:Cu ratio of the electroplated PdCu was varied to five different values and the condition of highest amperometric current at an identical of $H_2O_2$ concentration was chosen among them. The resulting amperometric current was highest when the ratio of Pd:Cu was 7:3 and this Pd;Cu ratio was employed in the sensor fabrication. The fabricated PdCu/LIG electrode based $H_2O_2$ sensor exhibited a sensitivity of $139.4{\mu}A/mM{\cdot}cm^2$, a broad linear range between 0 mM and 16 mM of $H_2O_2$ concentrations at applied potential of -0.15 V, and high reproducibility (RSD = 2.6%). The selectivity of the fabricated sensors was also evaluated by applying ascorbic acid, glucose, and lactose separately onto the sensor in order to see if the sensor ourput is affected by one of them and the sensor output was not affected. In conclusion, the proposed PdCu/LIG electrode based $H_2O_2$ sensor seems to be suitable $H_2O_2$ sensor in various applications.

수직배향액정셀에서의 광학특성향상을 위한 전극설계 (Design of electrodes in the Patterned Vertical Aligned Liquid Crystal Cell for high optical performance)

  • 이와룡;김경미;이기동
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.344-348
    • /
    • 2007
  • 본 논문에서 높은 투과율을 가질 수 있는 PVA (Patterned Vertical Aligned) 액정 셀의 전극 구조를 제안하였다. 제안한 전극 구조의 결과를 확인하기 위해서 광학적 특성과 그리고 디렉터 모양의 계산은 'TechWiz LCD'라는 상용 시뮬레이터를 사용하였다. 보통 PVA 액정 셀의 투과율은 전극의 모양과 셀갭에 의해 크게 영향을 받는다. 본 논문에서 제안한 전극 구조의 게이트 라인과 데이터 라인 사이의 거리는 기존의 PVA 셀과 같다. 대신 전극의 끝단 (edge) 지역에서의 광손실을 줄이기 위하여 상층부 전극과 하층부 전극의 모양을 수정하였다. 결과를 비교하기 위하여 기존의 PVA 액정 셀과 제안한 PVA 액정 셀의 투과율을 비교하였다. 그 결과, 제안된 구조에 의해서 전극부근에서 발생하는 광학적 손실이 감소되는 것을 확인 할 수 있었다.

직류전기장에 의한 기포의 변형과 이탈에 관한 연구 (A Study on the Bubble Deformation and Departure Under DC Electric Field)

  • 권영철;김무환;강인석;김석준
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.