Survey on sewerage operation/management planning for flooding (I) (하수관거시설의 침수대응 운영·관리 실태 연구 (I))

  • Ryu, Jaena;Hwang, Sung-Hwan;Oh, Jeill;Hyun, In Hwan;Kim, Young-Ran;Kim, Chan-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.265-270
    • /
    • 2009
  • A nationwide questionnaire survey was conducted to investigate the actual conditions of local authorities in operating and maintaining sewerage systems especially for urban flooding. The questionnaire includes the incidences of flooding since 1980, the existence of any guidance for preventing flood damage and the design frequency currently used for sewers in each local authority. Among 160 local authorities responded to the survey, 95(59.3%) has experienced flooding more than once since 1980 while only 36(37.9%) of the 95 has prepared operation/maintenance guidelines for flooding. Most of the respondents have applied the 10 year design frequency for sewer design and 57(35.6%) of them agreed to adjust the 10 year design frequency regulation.

Economies of Scale in the Sewerage Treatment Sectors of Cheonla Province Area (전라남북도 하수처리시설 운영에 대한 규모의 경제성 분석)

  • Kim, Kyunghag;Yoo, Seung-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2013
  • This Study includes the information of integrated discussion and economies of scale on local governments' sewerage treatment plant through translog function based on the reality reports of sewerage treatment plant operation published by Ministry of Environment and sewerage statistics data from 2005 to 2010. Based on analysis results from the data of 35 local governments in Jeollanamdo and Jeollabukdo, which are selected as pilot project areas of sewerage facility integration by Ministry of Environment and have low percent of sewered population, it shows the existence of economies of scale. The economies of scale on sewerage treatment show the loss of approximately 22,211 thousand ton/day in sewage treatment, it is 1.7 times compared to the average treatment amount of 35 local governments as of 2010. It means the economies of scale can be achieved by lowering operation cost along with large scale integration in installation, operation and maintenance due to the features of sewerage industry as one of network industry.

Development of a System Dynamics Model for the Efficient Operation and Maintenance of Sewerage Systems (하수도 시스템의 효율적인 운영 및 유지관리를 위한 시스템다이내믹스 모형의 개발)

  • Park, Su-Wan;Lee, Tae-Geun;Kim, Bong-Jae;Kim, Tae-Young
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.101-111
    • /
    • 2012
  • In this paper, the feedback loop mechanisms among the operational indices and exogenous variables of a sewerage system that are inherent in the operation and maintenance of a sewerage system were identified using the System Dynamics (SD) modeling methodology. The identified feedback loops were used to develop a SD computer simulation model that can be used to predict future operational conditions of a sewerage system and identified the efficient ways of operation. The data of Busan metropolitan city sewerage system was applied to verify the developed SD model and predict future operational conditions of the system. As a result, it was predicted that sewage treatment efficiency, volume of sewage treatment and cost recovery rate will be gradually increased, whereas service rate which was already very close to the target will remain almost the same as the current value. Furthermore, sensitivity analysis concerning some operational indices was performed in order to discover the policy leverage. As a result, it was found that the exogenous variables related to the pipe maintenance had a great effect on facility using rate, volume of sewage treatment as well as sewage treatment efficiency.

State of Swerage Systems and Prospects in Korea (우리 나라의 하수도현황과 전망)

  • 김갑수
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.65-84
    • /
    • 1993
  • This study reviewed the current status and problems of sewerage system in Korea and then proposed possible methods to correct the problems. Also, evaluation of future development in sewerage system is included. It can be summarized as follows : 1. Investment in sewerage system is relatively low . 0.23% of GNP, Considering that the investment portion is 0.35% in OECD and 0.63% in Japan, it should be increased further. 2. The reasons wily the investment in sewerage system is low can be ' (1) Low priority is given to the investment in sewerage system. Local government builds and operates its own wastewater treatment plant. Local government as well as residents prefer to invest their money in roadwork, housing and parks to in wastewater treatment facilities because of greater investment effects. (2) Besides capital investment, more maintenance cost is needed for sewerage system. Proper operation of wastewater treatment facilities requires a well-trained operator. Because of public conception that operation of wastewater treatment facility is a dirty job, it is difficult to find a well-trained operator. (3) It is difficult to estimate the effect of sewerage system (4) Cost required to build and maintain wastewater treatment facility should be paid by people, who benefit from the facility. People to benefit are sometimes different from people to pay. 3. Advanced treatment is necessary to protect the bay aura and raw water source as well as to prevent eutrophication of lakes and ponds. 4. Wastewater treatment facility were mainly build in big cities during the decade of 1980. Followings should be solved first to expand the facilities. (1) Rapid repair and construction of sewer. (2) Technical development of wastewater treatment . Prevention of efficient and economical wastewater . Development of efficient and economical wastewater treatment techniques . Development of high-efficiency treatment using bioreactor . Reuse of wastewater treatment plant effluent (3) Sludge treatment and disposal . Composting of sludge cakes . Development of techniques to reduce the volume of sludge cake : incineration and reuse of sludge ash and slag. (4) Utilization of wastewater treatment facilities . Construction of community parks or sports families(ie, on the tops of the covered aeration tanks and sedimention tanks) Construction of wastewater treatment facilities under ground and of parking facilities and community parks above ground. (5) Education of wastewater treatment personal.

  • PDF

Appropriate Sewerage Systems for Korea (우리나라 적합 하수도시설 및 관리방안)

  • 이상은
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.37-52
    • /
    • 1992
  • Since the first sewage treatment plant was constructed in 1976, the sewerage systems of Korea have been rapidly expanded. As of the end of 1991, 22 sewage treatment plants with total capacity of 5.4 million tons/day are in operation which is equivalent of 3395 total daily sewage generation. Total extension of sewer 39.534 km in 1990 which is 55% of the target extension for the year 2001. However, the most sewage treatment plants employ activated sludge process which may not be suitable for medium and/or small scale plants. The poor existing sewer systems do not effectively collect and transport sewage to adversely affect the function of sewage treatment plant. To select the appropriate treatment system, the cities are classified into 3 categories such as large and medium size inland cities, small size cities and coastal cities. Considering the criteria suggested during this study, appropriate treatment processes were selected for each category. Conventional activated sludge process and step aeration process were found to be the most appropriate for big inland cities while biological nutrient removal processes should be considered for the cities discharge the effluent to lakes or reservoirs. RBC or Oxidation Ditch process might be appropriate for the medium size cities while several processes which do not require skilled operation and maintenance were suggested for the small cities. Ocean discharge after primary treatment can be considered for some east coast cities, Appropriate methodology to rehabilitate the existing sewers and strategy to convert combined sewer system to separate sewer system were proposed. This paper also include the appropriate management system for industrial wastewater, sludge and nightsoil.

  • PDF

Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

A review on vibration-based structural pipeline health monitoring method for seismic response (지진 재해 대응을 위한 진동 기반 구조적 관로 상태 감시 시스템에 대한 고찰)

  • Shin, Dong-Hyup;Lee, Jeung-Hoon;Jang, Yongsun;Jung, Donghwi;Park, Hee-Deung;Ahn, Chang-Hoon;Byun, Yuck-Kun;Kim, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.335-349
    • /
    • 2021
  • As the frequency of seismic disasters in Korea has increased rapidly since 2016, interest in systematic maintenance and crisis response technologies for structures has been increasing. A data-based leading management system of Lifeline facilities is important for rapid disaster response. In particular, the water supply network, one of the major Lifeline facilities, must be operated by a systematic maintenance and emergency response system for stable water supply. As one of the methods for this, the importance of the structural health monitoring(SHM) technology has emerged as the recent continuous development of sensor and signal processing technology. Among the various types of SHM, because all machines generate vibration, research and application on the efficiency of a vibration-based SHM are expanding. This paper reviews a vibration-based pipeline SHM system for seismic disaster response of water supply pipelines including types of vibration sensors, the current status of vibration signal processing technology and domestic major research on structural pipeline health monitoring, additionally with application plan for existing pipeline operation system.

A Study on Nitrification and Denitrification in Biofilter & Sulfur- Limestone Single Stream Process (바이오필터와 황-석회석을 이용한 단일흐름 공정에서의 질산화와 탈질 연구)

  • Kim, Tae-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.469-477
    • /
    • 2006
  • When denitrification was connected with a single stream process by using biofilter and sulfur-limestone, it was found that such connection enabled highly efficient nitrification without special unit operation of microorganisms or injection of external carbon sources which is being shown in general biological treatment processes. It was observed that in the trickling filter bed, decomposition of organic substances and highly efficient nitrification by both the forced pressure feed trickling and the air fan were simultaneously done. In the denitrification tank where sulfur-limestone was mixed at a certain ratio, limestone was used by autotrophic microorganisms as a source of supply for alkalinity, and nitrate $NO_{3}^{-}$-N was denitrified into nitrogen gas. And in the sulfur-limestone autotrophic denitrification, $NO_{3}^{-}-N\;or\;NO_{2}^{-}-N$ was denitrified as a sulfur compound in reduction state was oxidized into a final output of $SO_{4}^{-2}$. The mean concentration of the discharge water was 8.6 mg/l for T-N and 0.8 mg/l for T-P, respectively, and their mean treatment efficiency was 79.2% and 80.8%, respectively. Implementing highly efficient denitrification without injection of an external organic carbon source or internal return, it is concluded that the proposed process is suitable for a sewerage in a small village with the merits of low power consumption and easy maintenance.

The Effect of Sewer Pipe Retrofit on The Operation of Sewage Treatment Plant in Rural Area (농촌 지역의 하수관거 정비사업이 하수처리장 운영에 미치는 영향)

  • Kim, Seongjung;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • Recently, rural areas are rapidly developing, while existing infrastructure is inadequate and aging compared to developing rural areas. The most representative of these is the sewer system. Therefore, in this study, the rural area of Gyeonggi A city was selected as the study area and analyzed the effect of the sewer maintenance business on the operation of the sewage treatment plant. The analysis items were pollutant treatment efficiencies, the changes of inflow sewage amount, sewage concentration, influnet load, and C / N ratio by comparing before and after the development. As a result of the analysis, the sewage amount increased significantly after the development, and the sewage concentration increased after the development and the load of the sewage in the wastewater treatment plant also increased after the development. And improvement and management of inflow of unidentified water such as infiltration water and influent water in the sewage pipe was improved due to improvement of sewage pipe, which is considered to have affected the increase of C / N ratio and the improvement of TN and TP removal efficiency. The results of this study can be used as a representative example of the sewerage maintenance project in the rural area that positively influenced the operation of the sewage.

A Study on the Development of Long-term Self Powered Underground Pipeline Remote Monitoring System (자가 발전형 장기 지하매설배관 원격감시 장치 개발에 관한 연구)

  • Kim, Youngsear;Chae, Hyun-Byung;Seo, Jae-Soon;Chae, Soo-Kwon
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.576-585
    • /
    • 2018
  • Systematic management during the whole life cycle from construction to operation and maintenance is very important for the seven underground pipelines (waterworks, sewerage, electricity, telecommunications, gas, heating, oil including waterworks and sewerage). Especially, it is the construction process that affects the whole life cycle of underground buried pipeline. In order to construct a new city or to maintain different underground pipes, it is always necessary to dig the ground and carry out construction and related work. There is a possibility that secondary and tertiary breaks frequently occur in the pipeline construction process after the piping constructed first in this process. To solve this problem, a system is needed which can monitor damage in real time. However, the supply of electric power for continuous operation of the system is limited according to the environment of underground buried pipelines, so it is necessary to develop a stable electric power supply system using natural energy rather than existing electric power. In this study, we developed a system that can operate the pipeline monitoring system for long time (24 hours and 15 days) using natural energy using wind and solar light.