• Title/Summary/Keyword: sewerage facilities

Search Result 55, Processing Time 0.026 seconds

A Study on the Evaluation for Operations of Public Sewage Treatment Plants Using Statistics Technique (통계기법을 이용한 공공하수처리시설의 운영실태 평가방법 연구)

  • Choi, In-Cheol;Ahn, Tae-Ung;Yu, Soon-Ju;Chung, Hyen-Mi;Kwon, Oh-Sang;Kim, Won-Ky;Yeom, Ick-Tae;Son, Dae-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.524-531
    • /
    • 2014
  • Korea has been trying to manage water quality of rivers and lakes in many ways. Ministry of Environment is making continuous efforts of operation control improvement such as strengthening effluent standards in sewage treatment plants and expanding Tele-Monitoring System (TMS). However, evaluation method for operations of sewage treatment plants and establishment system of effluent standards are inadequate. The objective of this study is to evaluate for operations of sewage treatment plants using statistics technique such as frequency analysis, percentile, normal distribution analysis. We used the effluent data (BOD, COD, SS) collected at 299 plants in 2012. The values were very low by comparison with standards. The Data followed a normal distribution. We think that distribution characteristics are closely related with effluent standards, especially T-P and BOD. Statistics technique attempted in this study can be used to evaluate for operations of sewage treatment plants and assess the appropriateness of effluent standards based on TBEL(Technology-based effluent limitation). And, this technique can be used to figure out the overall level of plants, the status of each plant and the favorable treatment process for each item (BOD, COD etc.). Data acquired through this method can be used to improve facilities and operation techniques and decide on a sewerage policy.

Analysis on the Settlement Conditions in the Troubled Reclaimed Areas Under State Control (III) - Living Conditions in Rural communities - (未完工干拓地의 定住生活 實態分析 (III) - 部落의 生活環境 -)

  • Choi, Soo-Myung;Hwang, Han-Cheol
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.3
    • /
    • pp.73-80
    • /
    • 1991
  • In Korea, small-scale reclaimed areas have been suffering from many problems because of the lack of comprehensive developing strategy although considerable investments have been inputed by the public sector since 1970's. For 3 reclaimed sites in Chonnam Province chosen as case study areas, the analysis, the third attempt of widely-spanned studies on areal conditions, concentrated on their living conditions. Its results were as follows : 1. Although rural residents have increased their concern on health and medical services, the public sector can only serve basic and emergent level of them, and therefore, the private sector, which is mostly placed in urban areas and costed much higher than public one, has the dominant share of those services. So, because those costs are a great expense to rural residents, their supplying system should be planned with special reference to lightening the economic burden of them. 2. By the development of locally fitted programs and innovative systems, the rural education should be qualitatively improved to deal successfully with its small scale. That will result in increasing the schooling rate to schools in rural communities, lightening the economic burden of rural residents on education services and finally activating them to contribute the betterment of rural education. 3. Servicing level of water supply, sewerage and garbage disposal in the reclaimed areas has been remaining at the lower order even in other rural areas. In the design of rural water supply, average daily consumption per capita should be changed according to the composition rate of fishing households and variety of the source of water supply. 4. Most of rural residents in the reclaimed areas want to establish the welfare facilites for the infant, youth, aged and public bath However in the long-term basis, the cooperative production and processing facilities should be considered for modernized efficient farming.

  • PDF

A fundamental study on the sulphate-resistant mortar using waste glass fine powder and meta-kaolin according to various fine aggregates (잔골재 종류에 따른 폐유리 미분말 및 메타카올린을 사용한 내황산염 모르타르에 관한 기초적 연구)

  • Jeong, Dongwhan;Park, Junhui;Ahn, Taeho;Park, Yeongsik;Sho, Kwangho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.3
    • /
    • pp.115-121
    • /
    • 2017
  • The degradation of the concrete due to deterioration factors, such as corrosion of steel bars, cracks and structural strength of reinforced concrete structures, is a social problem. Especially, concrete structures constructed in seawater, underground water, waste water treatment facilities and sewerage are subject to chemical attack by acid and sulphate. Therefore, this study was conducted to compare sulfated glass and fine aggregate of slag using waste glass fine powder and meta kaolin. The results showed that the slag fine aggregate showed better sulfate resistance than the river sand, and the fine powder of waste glass showed the best performance at 3 % displacement.

Daily influent variation for dynamic modeling of wastewater treatment plants

  • Dzubur, Alma;Serdarevic, Amra
    • Coupled systems mechanics
    • /
    • v.9 no.2
    • /
    • pp.111-123
    • /
    • 2020
  • Wastewater treatment plants (WWTPs) with activated sludge system are widely used throughout the most common technologies in the world. Most treatment plants require optimization of certain treatment processes using dynamic modeling. A lot of examples of dynamic simulations require reliable data base of diurnal variation of the inflow and typical concentrations of parameters such as Chemical Oxygen Demand (COD), Total Kjeldahl Nitrogen (TKN), etc. Such detailed data are not available, which leads to problemsin the application of dynamic simulations. In many examples of plants, continuous flow measurements are only performed after the primary clarifier, whereas measurements from influent to the plant are missing, as is the case with the examples in this paper. In some cases, a simpler, faster and cheaper way can be applied to determine influent variations, such as the "HSG-Sim" method ("Hochschulgruppe Simulation"). "Hochschulgruppe Simulation" is a group of researchers from Germany, Austria, Switzerland, Luxembourg, Netherlands and Poland (see http://www.hsgsim.org). This paper presents a model for generating daily variations of inflow and concentration of municipal wastewater quality parameters, applied to several existing WWTPs in Bosnia and Herzegovina (B&H). The main goal of the applied method is to generate realistic influent data of the existing plants in B&H, in terms of flow and quality, without any prior comprehensive survey and measurements at the site. The examples of plants show the influence of overflow facilities on the dynamics of input flow and quality of wastewater, and a strong influence of the problems of the sewerage systems.

Burden of Disease Attributable to Inadequate Drinking Water, Sanitation, and Hygiene in Korea

  • Kim, Jong-Hun;Cheong, Hae-Kwan;Jeon, Byoung-Hak
    • Journal of Korean Medical Science
    • /
    • v.33 no.46
    • /
    • pp.288.1-288.12
    • /
    • 2018
  • Background: Diarrheal and intestinal infectious disease caused by inadequate drinking water, sanitation, and hygiene (WASH) is not only a great concern in developing countries but also a problem in low-income populations and rural areas in developed countries. In this study, we assessed the exposure to inadequate WASH in Korea and estimated the burden of disease attributable to inadequate WASH. Methods: We used observational data on water supply, drinking water, sewage treatment rate, and hand washing to assess inadequate WASH conditions in Korea, and estimated the level of exposure in the entire population. The disease burden was estimated by applying the cause of death data from death registry and the morbidity data from the national health insurance to the population attributable fraction (PAF) for the disease caused by inappropriate WASH. Results: In 2013, 1.4% of the population were exposed to inadequate drinking water, and 1.0% were living in areas where sewerage was not connected. The frequency of handwashing with soap after contact with excreta was 23.5%. The PAF due to inadequate WASH as a cluster of risk factors was 0.353 (95% confidence interval [CI], 0.275-0.417), among which over 90% were attributable to hand hygiene factors that were significantly worse than those in American and European high-income countries. Conclusion: The level of hand hygiene in Korea has yet to be improved to the extent that it shows a significant difference compared to other high-income countries. Therefore, improving the current situation in Korea requires a continuous hand washing campaign and a program aimed at all people. In addition, continuous policy intervention for improvement of sewage treatment facilities in rural areas is required, and water quality control monitoring should be continuously carried out.

Introduction to Image Processing Technology for Precise Positioning of Underground Buried Lifelines (영상정보 기반 지하매설관 정밀 위치조사 기술 소개)

  • Ryu, Byunghyun;Cheon, Jangwoo;Lee, Chulhee;Lee, Impyeong;Lee, Jangguen;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.51-57
    • /
    • 2021
  • Underground lifelines such as water supply/sewer pipe, power cable and gas pipe are indispensable facilities to the life of urban society. These lifelines have been constructed long time ago and buried positioning information is not precisely recorded. Moreover, they have been concentrated on the narrow area and are complicatedly entangled in 3-dimension. In the fourth industrial revolution, a 3-dimensional visualization for underground lifelines is strongly required, and a database (D/B) with precise positioning information should be preceded. In this study, image processing technology for precise positioning of underground buried lifelines is introduced, which is able to build the database more accurately, efficiently and practically.

Monitoring Method Using Moving CCTV in Common Duct (이동형 CCTV 장치를 이용한 공동구 모니터링 방법)

  • Kang, Jin-A;Kim, Tae-Hoon;Oh, Yoon-Seuk;Choi, Hyun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.1-12
    • /
    • 2011
  • There has been the increasing concern with the safety of seven major urban infrastructure such as road, electricity, water supply, sewerage and so on due to urban expansion and new town development. However, high technology development for the common duct which can be an alternative for the safety issue has not been completed due to the law of the national security area. Existing management method of the common duct by people could not respond to the urgent accidents adequately and immediately since it is impossible for us to get access to that in case of fire or gas leak. This study suggests to the method of installing monitoring devices and processing CCTV images with a water supply in a TestLab(a variety of the USN(Ubiquitous Sensor Network) equipment was tested in the TestLab in KICT). The suggested management method of common duct facilities make it possible to do real-time monitoring and prompt access and response to an accident inside the common duct.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.

A Strategy for Improving the Sewerage Systems of Two Rural Areas in Gyeonggi Province (경기도의 2개 시.군 사례를 통한 농어촌지역 하수도 정비 추진 방안)

  • Moon, Chul-Hwan;Ahn, Ji-Hoon;Jang, Mi-Jeong;Lee, Sang-Hyup;Cho, Young-Moo;Kim, Yun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.563-580
    • /
    • 2010
  • In 2009 the Korea Ministry of Environment announced 'A Comprehensive Plan for the Improvement of Sewer Service in Rural Area' aiming at reduction of the sewer service gap between urban and rural areas as well as improvement in the residential environment of the rural area. According to the plan, the sewer system supply rate for the rural area is expected to reach up to 75% until 2015 with the budget of 4.7 trillion won (Korean currency). It is not certain, however, that the increase in the sewer system supply rate will accompany improvement of water quality in receiving water because several veiled problems that can occur in small-scale sewer treatment plants are poorly addressed in the plan. In this study, those issues for the small-scale sewer treatment plants and their solutions were discussed based on a case study in which we investigated 19 treatment facilities at two rural regions in Gyeonggi province. This study also included strategies useful for the plan. From the results of investigation, some problems, e.g., high hourly variations but low in flowrates and low mass loading were commonly identified. Although operation parameters in sewer treatment plants require to be modified depending on the mass loading, most of the plants were operated with the initial design parameters which causes the decrease of removal efficiency. In the intensive diagnosis, we arranged and applied solutions (e.g., flow equalization, air on/off time control, etc) to the two selected plants and found out improvement of effluent water quality, especially organic matters (COD and SS) and T-N with better denitrification performance.