• Title/Summary/Keyword: sewer data

Search Result 184, Processing Time 0.027 seconds

Data complement algorithm of a complex sewerage pipe system for urban inundation modeling

  • Lee, Seungsoo;An, Hyunuk;Kim, Yeonsu;Hur, Young-Teck;Lee, Daeeop
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.509-517
    • /
    • 2020
  • Geographic information system (GIS) sewer network data are a fundamental input material for urban inundation modeling, which is important to reduce the increasing damages from urban inundation due to climate change. However, the essential attributes of the data built by a local government are often missing because the purpose of building the data is the maintenance of the sewer system. Inconsistent simplification and supplementation of the sewer network data made by individual researchers may increase the uncertainty of flood simulations and influence the inundation analysis results. Therefore, it is necessary to develop a basic algorithm to convert the GIS-based sewage network data into input data that can be used for inundation simulations in consistent way. In this study, the format of GIS-based sewer network data for a watershed near the Sadang Station in Seoul and the Oncheon River Basin in Busan was investigated, and a missing data supplementing algorithm was developed. The missing data such as diameter, location, elevation of pipes and manholes were assumed following a consistent rule, which was developed referring to government documents, previous studies, and average data. The developed algorithm will contribute to minimizing the uncertainty of sewer network data in an urban inundation analysis by excluding the subjective judgment of individual researchers.

A Study for Particle use of Sewer Flow Data by using ToSS (ToSS를 이용한 하수관거내 유량데이터 활용방안에 관한 연구)

  • Choi, Gye-Woon;Lee, So-Young;Lee, Ho-Sun;Kim, Jung-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1410-1414
    • /
    • 2006
  • Infiltration and Inflow(I/I) through the old or broken sewer are caused falling efficiency of sewage treatment plants. Recently, to solve these problems maintenance work of sewer pipes is progressing and sewer flow is metered for I/I survey. In this paper, metered sewer data at GyeongGi-Do H city for two years are analyzed by ToSS program. And this paper suggest particle use of sewer flow much data for many years.

  • PDF

Estimation of sewer deterioration by Weibull distribution function (와이블 분포함수를 이용한 하수관로 노후도 추정)

  • Kang, Byongjun;Yoo, Soonyu;Park, Kyoohong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.251-258
    • /
    • 2020
  • Sewer deterioration models are needed to forecast the remaining life expectancy of sewer networks by assessing their conditions. In this study, the serious defect (or condition state 3) occurrence probability, at which sewer rehabilitation program should be implemented, was evaluated using four probability distribution functions such as normal, lognormal, exponential, and Weibull distribution. A sample of 252 km of CCTV-inspected sewer pipe data in city Z was collected in the first place. Then the effective data (284 sewer sections of 8.15 km) with reliable information were extracted and classified into 3 groups considering the sub-catchment area, sewer material, and sewer pipe size. Anderson-Darling test was conducted to select the most fitted probability distribution of sewer defect occurrence as Weibull distribution. The shape parameters (β) and scale parameters (η) of Weibull distribution were estimated from the data set of 3 classified groups, including standard errors, 95% confidence intervals, and log-likelihood values. The plot of probability density function and cumulative distribution function were obtained using the estimated parameter values, which could be used to indicate the quantitative level of risk on occurrence of CS3. It was estimated that sewer data group 1, group 2, and group 3 has CS3 occurrence probability exceeding 50% at 13th-year, 11th-year, and 16th-year after the installation, respectively. For every data groups, the time exceeding the CS3 occurrence probability of 90% was also predicted to be 27th- to 30th-year after the installation.

Development and Application of Sewer Facility Management System (하수도 시설 관리 시스템의 개발 및 적용)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.279-285
    • /
    • 1999
  • An integrated sewer management system was developed for the analysis of sewer flow and for optimal operation of sewer works using ArcView and SWMM. SWMM and ArcView were dynamically linked together using Avenue in order to construct user-friendly management system. The developed system was applied to a residential area in Choonchun city to verify its utilities. All the relevant field data were analyzed on the basis of developed system, and the modeling of sewer flow was implemented using RUNOFF, EXTRAN, TRANSPORT in SWMM. This system is now in the process of connection to the management system of watershed and surface environment in order to develope an integrated environmental management system. Futhermore, this system will be a critical part of overall control system of sewer works including sewer line and wastewater treatment plant. As this system can provide comprehensive prediction of flow and pollution profiles, it could serve as a tool not only for optimal management, but also for decision support system to examine the efficiency of planning and implementation of sewer projects.

  • PDF

Comparison of infiltation rate for separate sewer system and combined sewer system in sewer maintenance areas (하수관로정비 지역의 분류식과 합류식 하수관로의 침입율 비교)

  • Gu, Gwangmo;Chu, Shaoxiong;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.191-200
    • /
    • 2020
  • This study is to improve the efficiency of BTL (Build Transfer Lease) project operation by comparing the infiltration rate based on the data of 5 years of infiltration of the separate sewer system and combined sewer system. In the survey site, the separate sewer system area consists of eight flowmeters in seven treatment basins, and the combined sewer system area consists of eight flowmeters in five treatment basins. The infillration rate was analyzed by night-time domestic flow evaluation method, and the average infiltration rates of the separate sewer system and combined sewer system were 13% and 16%, respectively. Combined sewer system was about 1.3 times higher than the separate sewer system. The average BOD of separate sewer system was 233 mg/L, which was about 2.4 times higher than the combined sewer system was 107 mg/L. In the comparison of the average pipe diameter-length infiltration of separate sewer system and combined sewer system, the separate sewer system and the combined sewer system were about 0.150 ㎥/d/mm/km and about 0.109 ㎥/d/mm/km, respectively. The floating population in mixed residential and commercial areas has been identified as the cause. Therefore, we propose a method to calculate the infiltration rate in consideration of the margin ratio in the area where the night active population is concentrated.

A Study on the Automatic Inspection of Sewer Facility Map (하수도시설물도 자동 검수 방안 연구)

  • Kim, Chang-Hwan;Ohk, Won-Soo;Yoo, Jae-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.2
    • /
    • pp.67-78
    • /
    • 2006
  • Local governments began to construct geographic information system to improve government productivity and performance. In support, central government organized a national commission for GIS. The master plan by NGIS has been the base for local government to participate in the construction of GIS at the local level in the under ground facilities management including water and sewers. The challenge faced by sewer facility managers includes controlling 'data accuracy'. The input for sewer data handling for efficient performance in local government requires accurate data. However data manipulation to get the 'good quality' data can be burdensome. Thus, the aim of this research is to provide the appropriate tool to guarantee the high quality of digital data in sewer facility management. It is helpful to pass the data examination by government as well as to insure confidence of decision and data analysis works in local government. In this research, error types of sewer data were classified and pointed the limitation of traditional examination methods. Thus this research suggested more improved method for finding and correcting errors in data input using sewer volume analysis and prediction model as immigrating sewer facility management work to Geographic Information System.

  • PDF

An Integrated Sewer Management System using Web Based Predictive Spatial Information System (웹 기반의 공간정보예측시스템을 이용한 통합적 하수도 관리 시스템의 개발 및 적용)

  • Kim, Joon-Hyun;Han, Young-Han
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2001
  • Web based integrated sewer management system was developed for the analysis of sewer flow and for the optimal operation of sewer works using ArcView and SWMM. SWMM and ArcView were dynamically linked together using Avenue in order to construct user-friendly information management system. The developed system was applied to the residential area in Choonchun city to verify its utilities. All the relevant field data were analyzed on the basis of the developed system, and the modeling of sewer flow was implemented using RUNOFF, EXTRAN, TRANSPORT in SWMM. This system is now in the process of connection to the management system of stormwater, surface and subsurface environment in order to develop an integrated environmental management system. Futhermore, this system will be a critical part of overall control system of sewer works including sewer network and wastewater treatment plant. As this system can provide comprehensive prediction of flow and pollution profiles, it could serve as a tool not only for the optimal management, but also for the decision support system to examine the efficiency of planning and implementation of sewer projects.

  • PDF

Development of Web based Watershed and Sewer Management System using Computational Model and GIS (전산모형과 지리정보시스템을 결합한 Web 기반의 유역 및 하수도 관리시스템의 개발)

  • Kim, Joon Hyun;Park, Hyung Choon;Han, Yung Han
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.63-71
    • /
    • 2000
  • A web based watershed and sewer management system was developed for the analysis of stormwater runoff and sewer flow, and for optimal operation of sewer works using ArcView and SWMM. SWMM and ArcView were dynamically linked together using Avenue and Visual Basic in order to construct user-friendly management system. The developed system was applied to Choonchun city to verify its utilities. All the relevant field data were analyzed on the basis of developed system, and the modeling of runoff and sewer flow was implemented using RUNOFF and TRANSPORT blocks in SWMM. This system was connected to the management system of surface and subsurface environment management system in order to develop an integrated environmental management system. Futhermore, this system will be a critical part of overall control system of sewer works including sewer line and wastewater treatment plant. As this system can provide comprehensive prediction of flow and pollution profiles and analytical tool equipped with Web-GIS, it could serve widely as a tool not only for optimal management, but also for decision support system to examine the efficiency of planning and implementation of sewer projects.

  • PDF

Analysis of the Effects of Sewer System on Urban Stream using SWMM based on GIS (GIS 기반의 SWMM 모형을 이용한 하수도시스템 선정에 따른 도시하천 수질개선효과의 정량적 분석)

  • Jang, Ju-Hyoung;Park, Hae-Sik;Park, Chung-Kil
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.982-990
    • /
    • 2006
  • Generally CSOs (Combined Sewer Overflows) are regarded as one of the most serious nonpoint pollution source in the urban watershed, Particularly, the water quality of the Oncheon stream is seriously affected by CSOs because the capacity of interception sewer system connected to the Suyoung wastewater treatment plant is too small to intercept most storm water discharges. The objective of this study is to evaluate the effect of nonpoint source on an urban stream with regards to combined sewer system and separate sewer system using GIS (Geographic Information System) and SWMM (Storm Water Management Model), and to provide an insight for the management of urban stream water quality. In order to consider the effect of CSOs on the receiving water quality, the flow divider element in SWMM was applied. The model calibration and verification were performed by the measured data of quantity and quality on the Oncheon stream. The quantity data acquired from the Suyoung wastewater treatment plant were also used for this procedure. In case of separate sewer system, the modeling results showed the increased tendency in streamflow compared with the combined system in dry weather, In addition, the water quality is remarkably improved in rainfall events at the separate condition. The results imply that the construction of separate sewer system should be taken into first consideration to restore the quality and quantity of water in urban streams.

Conservative Adjustment of the Standard Calculation Method of Inflow Water Into a Separated Sewer System (분류식 하수관로에서 유입수 표준매뉴얼 산정방법의 보수적 수정 결과)

  • Chu, Minkyeong;Bae, Hyokwan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.423-430
    • /
    • 2020
  • To improve the low treatment efficiency of sewage treatment plants, the separated sewer system must be maintained to provide an adequate flow rate and quality of the sewage under the effect of inflow. In this study, data from five locations of Namsuk, Dukgok1, Dukgok2, Kanggu, and Opo were used to conservatively calculate the inflow water volume. The sewer flow and rainfall data were collected in 2017. The factors in the standard method used to calculate the inflow of the combined sewer pipes including "rainy days", "rainfall impact period", and "period for basal sewer" were defined as 3 mm/day, continuous rain for two days, and two weeks prior to the inflow generation, respectively. "Rainy days", "rainfall impact period", and "period for basal sewer" were conservatively adjusted to 5 mm/day, continuous rain for five days, and three weeks prior to the inflow generation, respectively. As a results of the adjustment, the linearity (r2) was improved except for in Dukgok1. This implies that the conservative adjustment made in this study could improve the management quality of sewer pipes. Also, the linear correlation coefficient (ai) between inflow and rainfall showed a large difference between the target locations, which can be another monitoring factor affecting the quality of sewer pipes. To improve the correlation based on the individual characteristics of the locations in Korea, the automatic algorithm for the inflow calculation should be developed by innovative intellectual technologies for application to the entire national area.