Discharged pollution load is varied as rainfall changes in the area with combined sewer system. Changes in discharged pollution load are directly related with those of sewer transfer flow. Therefore, it is important to identify the pattern of sewer transfer flow for the analysis of changes in discharged pollution load. This study reviewed the type of distribution of sewer transfer flow for 17 sewage treatment plants and developed simple formular to estimate sewer transfer flow as rainfall changes. 11 facilities showed to have some relation with rainfall in the change of sewer transfer flow but 6 facilities to have no relation. Relationships between rainfall amount and sewer transfer flow showed that 6 facilities out of 11 had relatively strong relationships above R2=0.5, which were considered to be affected directly by rainfall changes. The formular which explain the relationship between rainfall and sewer transfer flow can be applied in the analysis of rainfall effects on discharged pollution load, therefore, the more appropriate evaluation will be done.
The purpose of this dissertation is to build a development density control model and estimate optimum developmental density level for a sustainable urban growth management. To develop the model, system dynamics modeling approach was used. The model was developed to analyze how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. The model was applied to Anyang city to estimate optimum density level. Extensive computer simulation was conducted to find out the maximum numbers of population, industry structure, houses, and cars that can be adequately sustained with the current Anyang city's infrastructure capacity. The computer simulation result shows that the city is overpopulated by some 90,000 people. It nab analyzed that 20% increase of existing capacity of urban infrastructure is necessary to support current population of Anyang city. To reduce the population to the adequate level whereby the current urban infrastructure can sustain, the current city regulation on floor area ratio needs be strengthened at least 20% to 35%.
대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
/
pp.443-447
/
2001
A laboratory-scale electrodewatering system for enhancing conventional filter pressure dewatering by an electric field has been developed to decrease the water content of sludge generated in the wastewater treatment. It consists of a piston-typed filter press, a power supply and data acquisition system. The offset of electrodewatering is investigated as a function of applied pressure, applied voltage, sludge type and filtration time. Also the optimal conditions for maximizing the dewatering efficiency in the eletrodewatering system are investigated. Electric field strength and mechanical pressure are in the range of from 0 to 120 V/cm and from 98.1 to 392.4 kPa. The dewatering rates increased with increasing electric strength. These experiments produced a final sludge cake with water content of 60 wt% using electrodewatering technology, compared with a 80 wt% using pressure filtration alone. The conventional filtration system using the electrodewatering shows the potential to be effective method for improving dewatering Sludge.
본 연구에서는 용수재이용을 위해 생활하수를 지하흐름형 인공습지로 처리한 후 연못시스템에 연결시켜 미생물과 각 수질인자들의 처리효과를 분석하였으며, 그 결과를 요약하면 다음과 같다. SS의 농도는 얼음이 녹은 3월 초순에서 4월 초순까지는 10 mg $L^{-1}$ 이하의 매우 낮은 농도로 우리 나라 방류수 수질기준보다 낮은 농도를 유지할 수 있었으나 겨울이나 여름 특정기간에 농도가 높아서, 용수 재이용시 보건 ${\cdot}$ 위생적인 측면과 더불어 이용자에게 심미적인 불편함이 없어야 하므로 유출부에 여과시설 등 관리대책을 검토할 필요가 있을 것으로 생각된다. $BOD_5$는 식물의 생장과 미생물의 성장이 저조한 동절기의 농도 증가현상과 이들의 활동이 활발한 성장기의 감소현상을 뚜렷히 나타내었으나, 전체적으로는 국제적인 농업용수 재이용 수질기준보다 낮은 수준으로서 우려할 사항이 아닐 것으로 판단된다. 영양물질의 경우 DO가 상승한 호기성상태에서 T-N, T-P 농도가 감소하는 것을 확인할 수 있었다. 수질개선을 목적으로 연못시스템을 이용할 경우 3월중에 상층부를 유출시키고 3월 이후에는 수심을 낮게 유지하여 심수층까지 호기성상태를 유지하는 것이 수질관리에 유리할 것으로 판단된다. 지하흐름형 인공습지에서의 미생물 처리효율은 TC, FC, E. coli 모두 평균 92 ${\sim}$ 96% 이상 높은 처리 효율을 보였으며, 인공습지 유출수가 연못시스템을 거치면서 추가로 평글 83 ${\sim}$ 90% 이상 제거되어 평균 대장균농도가 1,200MPN 100 $mL^{-1}$ 로써 인공습지와 연못시스템을 연계 ${\cdot}$ 적용한 후 농업용수로 재이용하거나 수계로 방류할경우 보건 ${\cdot}$ 위생상의 문제를 크게 줄일 수 있을 것으로 판단된다. 미생물의 소독은 대부분 태양광에 의해서 이루어지기 때문에 본 연구와 같이 연못 상층부에서 유출시킬 경우 높은 처리효율을 기대할 수 있을 것으로 생각하며, 대장균과 연못 내에 존재하는 생물들 사이의 상호작용을 정확히 이해하여 적절한 관리대책을 마련 할 경우 안정적인 방류수 농도를 확보할 수 있을 것으로 판단된다. 자연정화로서 하수처리수를 고도 처리할 수 있는 인공습지와 연못시스템을 연계처리 하면 높은 미생물 소독효율을 나타내어 보건 ${\cdot}$ 위생상의 문제를 크게 줄일 수 있을 것으로 기대된다. 인공습지와 연계한 연못시스템의 하수처리방식은 간단한 구조, 큰 완충능력, 적은 슬러지 발생, 간소한 유지 ${\cdot}$ 관리의 장점을 가지고 있어서, 소규모하수처리와 농업용수 재이용 기술로서 적용가능성이 클것으로 판단된다.
A prototype surface flow constructed wetland was built in the upstream area of Sihwa reclaimed tidal lands to improve the water quality of Lake Sihwa by treating severely polluted stream water. In this study, we monitored hydrology, macrophyte (Phragmites communis Trin,) growth, and water quality in the Banwol and Donghwa wetlands to evaluate their performance during the initial period after the completion of wetland construction, The average removal efficiency($\%$) in each wetland was relatively low compared with the performance data from the North America Wetland Treatment System Database (NADB), which mainly includes urban sewage-treatment wetlands. However, the average removal rates per unit area ($g/m^{2}/day$) were 0.72, 0.72 and 0.51 (BOD), 2,04, 2.46 and 0.70 (SS), 0.89, 0.43 and 1.09 (TN) and 0.02, 0.02 and 0.02 (TP) in the Banwol and Donghwa wetlands and NADB, respectively. The overall performance of the Banwol and Donghwa wetlands was within the expected range of the wetland system processes contributing the reduction of the pollutant load to Lake Sihwa during the initial period of wetland operation. Considering the low influent concentration, high hydraulic loading rate, and insufficient macrophyte growth since the wetland was constructed, better performance is expected if an improved operational scheme is adopted.
Feasibility of simultaneous removal of organic materials and nitrogen in the wastewater from fisheries processing plant was evaluated using entrapped mixed microbial cell (EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were conducted from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kg\;T-N/m^3/d$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kg\;T-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate was removed efficiently at the anoxic tank. whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand (COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.
정수장, 하수처리장, 폐수처리장의 배출수 처리공정에서 고 농도의 슬러지 선별, 이송 및 약품 투입량 조절을 위한 기준으로 슬러지 농도계가 사용되고 있다. 그러나 슬러지에 함유된 이물질이 혼입될 경우 감쇄량이 증가하거나 초음파가 수신부에 전달되지 않아 실제 농도값 보다 높은 값을 출력하거나 헌팅현상이 발생한다. 또한 단일 센서에 슬러지 포착 또는 고장 등의 문제로 배출수 공정 자동화에 어려움이 많았다. 이러한 문제점을 개선하기 위해 초음파 다중빔 농도계를 개발하여 사용하고 있으나 특정 초음파 빔의 농도 측정값에 오류가 발생할 경우 전체 농도시스템의 성능이 떨어지는 단점이 있다. 따라서 본 논문에서는 초음파 다중빔 농도계 간의 신뢰성을 판단하고, 신뢰성이 높은 다중빔 농도계만을 사용하여 슬러지 농도 예측값의 성능 향상방안을 제시하였다. 예측 알고리즘으로는 뉴로-퍼지모델을 적용하였으며 다양한 실험을 통하여 제안된 방법의 타당성을 검증하였다.
수위는 하수장, 정수장, 하천, 댐, 공장의 저장탱크 등 다양한 분야에서 측정된다. 수위측정을 위한 초음파 기기가 판매중이나 산업용으로 실험에서 사용하기는 가격이 너무 비싸다. 전자 기술의 급속한 진보로 인해 다양한 종류의 측정, 모니터링 및 제어 기능이 저렴하게 구축하는 것이 가능해졌다. 저렴한 가격으로 초음파 수위 측정시스템을 만들기 위하여 본 연구가 시작되었다. 실험용으로 사용하기 위하여 아두이노, 초음파 센서 및 온도 센서로 시스템을 구성하였다. 초음파 센서는 센서에서 수위 표면까지의 시간을 측정한다. 온도 센서는 대기 온도를 측정하며 온도 변화로 인한 소리의 속도를 보정하여 초음파 거리 측정의 정확성을 높인다. 아두이노는 측정 전반을 관리하고 수위를 계산한다. 시스템의 모든 구성 요소는 장치거치대에 조립되었다. 제안된 시스템을 가지고 실험한 결과 수위가 실측치와 매우 가까웠다. 이 시스템은 또한 저렴하며 설치 및 유지하기가 쉬워 실험용으로 적절하다.
2012년부터 신재생에너지 의무공급제도가 국내에 도입되고, 전 세계적인 에너지 절약과 환경보존 측면에서 미활용 및 신재생에너지원에 대한 관심이 날로 증가하고 있다. 특히, 중저온 열원의 활용방안에 대하여 많은 관심과 연구가 활발하게 진행되면서 고부가가치의 전력생산이 가능한 유기랭킨사이클이 그 대안으로 떠오르고 있다. 따라서 본 연구에서는 유기랭킨사이클 발전시스템을 하수 처리장 1,500 kW 바이오가스엔진 배기열을 열원으로 하부 사이클을 구성하여 성능해석 상용 프로그램으로 성능특성을 예측하였다. 바이오가스엔진 배열의 실제 운전조건은 $460^{\circ}C$의 온도와 매 초당 2.7 kg의 유량으로 운전되고 있었다. 이러한 열원 온도에 적합한 작동유체를 다수 선정하여 작동유체 종류별 성능해석을 수행하였으며, 최고의 성능이 나타나는 이소펜탄의 경우 163.1 kW의 발전출력과 13.66%의 효율을 얻을 수 있었다.
The aims of this study were to investigate and confirm the occurrence and distribution patterns of iodinated X-ray contrast media (iopromide) in Nakdong river basin (mainstream and its tributaries). Iopromide was detected in 16 sampling sites. The concentration levels of iopromide on February 2011 and on October 2011 in surface water samples ranged from not detected (ND) to 1481.1 ng/L and ND to 1168.2 ng/L, respectively. The highest concentration level of iopromide in the mainstream and tributaries in Nakdong river were Goryeong and Jincheon-cheon, respectively. The sewage treatment plants (STPs) along the river affect the iopromide levels in river and the iopromide levels decreased with downstream because of dilution effects.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.