• Title/Summary/Keyword: settling efficiency

Search Result 172, Processing Time 0.025 seconds

Effect of Hydraulic Property and Mixing Intensity of Flocculation Basin on Flocculation Efficiency in Water Treatment Plant (정수장 플록형성지의 수리학적 특성과 교반강도가 플록형성 효율에 미치는 영향)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.230-235
    • /
    • 2005
  • The main purpose of the flocculation process is to make flocs bigger to be removed easily in the following processes. The flow pattern and mixing intensity have a great influence on flocculation. In this study, the flow pattern was examined by a hydraulic tracer-test, where 3 water treatment plants having $800,000m^3/d$, $44,000m^3/d$ and $40,000m^3/d$ were employed. Also, the settling test was conducted to find out the relationship between the mixing intensity and the settling ability of flocs. The hydraulic tracer-test was conducted for the various flocculation processes that have different structures of flocculation basins. In the result, the retention time distribution (RTD) curves for the flocculation processes were quite different. In case of the inappropriate structure of the flocculation basin, the flow is not even so that the floc does not grow enough. To find out the relationship between mixing intensity and settleability of flocs, G-values were calculated and the settling test was conducted for two flocculation basins which have the same conditions except the G-value. For the flocculation basin with uneven G-value, the floc settleability was revealed poor. On the other hand, the flocculation basin with even G-value, the settleability was better than the previous one. From these experimental results, it is confirmed that the flow pattern is closely related to the structure of the flocculation basin and the settleability is affected by mixing intensity. Therefore the flow pattern and the strength of the mixing intensity should be examined sufficiently to design and operate flocculation basin.

Evaluation of Hydrodynamic Behavior in Horizontal Settling Basin with Archimedes number (Archimedes number를 이용한 장방형 침전지내 수리흐름 평가에 관한 연구)

  • Park, No-Suk;Lee, Sanguk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.865-870
    • /
    • 2009
  • In this study, the adequacy of Reynolds numbers and Froude numbers derived from about sixty domestic water treatment plants (WTPs) were analyzed in order to estimate the characteristics of hydraulic behavior within the rectangular shaped sedimentation basins used widely. From the results of analysis, most of domestic WTPs have satisfied the criteria regulated as that Reynolds number should less than 1,000(dimensionless). On the other hand, they have not been able to satisfy the Froude number criteria, which should be higher than $1.0{\times}10^{-6}$. The reasons why most of domestic WTPs could not satisfy the criteria are that its criteria basis has been not only inadequate, but also the concept of external flow occurred around a settling particle has been ignored. Accordingly, this study proved the feasibility of Archimedes number, which indicates the ratio between particle Reynolds number and Froude number, to evaluate the hydraulic efficiency and its function of scale factor.

Shape and Formation of Aerobic Granulation in SBR (SBR에서 호기성 입상슬러지의 형성)

  • Yun, Zuwhan;Jang, Heeran;Han, Jonghun;Han, Hyejung
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.534-538
    • /
    • 2004
  • Granulation characteristics have been studied with an aerobic sequencing batch reactor(SBR). Organic loading of 2.46kg COD/$m^3$/day followed by 4.14kg COD/$m^3$/day had been applied to the lab-scale SBR with a very short settling time during the operating cycle. The granulation proceeded to the diameter range of 3 to 5 mm with MLSS concentration of 12,000mg/L at 45th days of operation while COD removal efficiency remained almost consistent after the granule formation. It has been noticed that aerobic granulation under the higher loading with a very short settling time seemed to be due to the microbial selection of better flocculating species.

Characteristics of water quality at Han stream retention ponds in Jeju City (제주시 한천 저류지의 수질 특성)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.207-214
    • /
    • 2013
  • To evaluate characteristics of water quality in Jeju, a study was implemented for Han stream and retention ponds. Inflow water quality of retention ponds was heavily dependent on precedent rainfall, and no pesticide was detected due to the little artificial pollution sources. A smooth settling efficiency curve was noticed because heavy particles were already settled down in front of the retention pond. There were weak relationships between retention time and water quality, and this can be attributable to high concentration of pollutants influx at peak inflow. In addition, as Han stream retention pond has a role of groundwater recharge, inflow control based on water quality as well as quantity is needed to maximize pollutant removal at the retention ponds.

Soft-Switching Auxiliary Current Control for Improving Load Transient Response of Buck Converter

  • Kim, Doogwook;Shin, Joonho;Shin, Jong-Won
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.160-162
    • /
    • 2020
  • A control technique for the auxiliary buck/boost converter is proposed herein to improve the load transient response of the buck converter. The proposed technique improves the system efficiency by enabling the soft switching operation of the auxiliary converter. The design guidelines for achieving capacitor charge balance for the output capacitor during the transient are also presented herein. The experimental results revealed that the output voltage undershoot and settling time during the load step-up transient were 40 mV and 14 ㎲, respectively, and the output voltage overshoot and settling time during the load step-down transient were 35 mV and 21 ㎲, respectively. The performance and effectiveness of the proposed technique were experimentally verified using a prototype buck converter with a 15-V input, 3.3-V output, and 200-kHz switching frequency.

  • PDF

Characteristics of Mixing and Coagulation in an Inline Coagulant Mixing System (인라인 응집제 혼화시스템의 혼화 및 응집특성)

  • Yang, Hei-Cheon;Park, Sang-Kyoo;Wang, Seung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3139-3143
    • /
    • 2007
  • The objective of this paper was to investigate the mixing characteristics of an three-stage inline coagulant mixing system experimentally. Wastewater samples of pH 8.5 and initial turbidity 1,000NTU were taken from a site of tunneling work. At the constant dosage, 0.36mL/L, of polymer as coagulant aids, the coagulation efficiency with the dosage of PAC as coagulant was about 4${\sim}$6% at 10 minutes after sampling. In the case of 2 different velocity gradient conditions, the efficiency of turbidity removal was increased about 6.5${\sim}$8% with increasing the dosage of coagulant while, the efficiency was increased about 20${\sim}$21.5% with increasing the dosage of coagulant aids. The efficiency of turbidity removal with the settling time after sampling was about 90% after 1 minute, and the efficiency was about 95% after 5 minutes.

  • PDF

Assessment of the fonction of Retention Pond, A-71 Motorway, France (프랑스 A-71고속도로변 Retention Pond의 기능평가)

  • 이평구;이재영
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.73-81
    • /
    • 1997
  • Retention ponds have been dug along some of the motorways to control water flow during rainstorms and to minmize environmental pollution. A retention pond located at Les Ardilleres about 20km South of Orleans along the A-71 motorway has been selected to evaluate the effectiveness of such a pond as a trap for heavy metals. Based on the "index of geoaccumulation" and the "enrichment factor" normalized to Fe introduced by Muller in 1979 and by Helz in 1976, respectively, the degree of contamination by heavy metals for the roadside soil and the settling particles was evaluated. As expected, the contamination was very severe in the roadside soil, while it was not so great in the settling particles. Using these methods, cadmium anomaly was traced in the settling particles of the retention pond, their occurrence being attributed partly to natural and partly to anthropogenic pollution. The estimated input of heavy metals associated with settling particles to the pond was 0.9 g/day Pb, 2.1 g/day Zn and 6mg/day Cd. A tentative mass balance of Pb and Zn originated by motor vehicles suggested that only 5 to l1% of heavy metals deposited on the surface of the motorway is carried to the retention pond by runoff water ; suggestions are made to improve their efficiency.ve their efficiency.

  • PDF

A Study on Prediction of Sedimentation Efficiency for Sedimentation Basin using Lagrangian Method (침전지의 유동 특성과 Lagrangian Method를 이용한 침전효율 예측에 관한 연구)

  • Choi, Jong-Woong;Hong, Sung-Taek;Kim, Seong-Su;Kim, Youn-Kwon;Park, No-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.229-236
    • /
    • 2017
  • Flow characteristics analysis and tracer test simulations for the rectangular typed sedimentation basins, which have been operated at D_water treatment plant in Korea, were carried out using CFD (Computational Fluid Dynamics) techniques for design ($15,864m^3/day$) and operation flowrate ($33,333m^3/day$). Also, each efficiency of the sedimentation basin was evaluated by application of the Lagrangin technique on the assumption of the particles flowing into the inlet of the sedimentation basin. From the results of simulation, the mean velocity values for making the flow in the settling basin as a plug flow region were derived as 0.00193 m/s and 0.00417 m/s, respectively. In addition, ${\beta}$ (effective contact factor) values were calculated to be 0.51 and 0.46, and the Morrill Index values were 6.05 and 3.21, respectively for both flowrate conditions.

Evaluation of the Effects of the Longitudinal Baffle on Settling Efficiency within Rectangular-shaped Sedimentation Basin (장방형 침전지내 도류벽의 침전효율에 대한 영향 평가)

  • Park, No-Suk;Kim, Seong-Su;Seo, In-Seok;Min, Kyong-En
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.573-581
    • /
    • 2009
  • In the case that the average velocity within rectangular-shaped sedimentation basin is less than 1.5cm/sec, and Froude number less than $10^{-6}$, it can not be expected that the longitudinal baffle improves the sedimentation efficiency. Also, since relatively lower velocity increases the effect of geostrophic body force, asymmetric flow pattern on a plane occurs within the basin. From the results of CFD (Computational Fluid Dynamics) simulation, in the case that the highest velocity within rectangular-shaped sedimentation basin is over 1.5cm/sec, and Froude number over $10^{-6}$, it can be expected that the longitudinal baffle installed within rectangular-shaped sedimentation basin improves the sedimentation efficiency.

On-Site Treatment of Soil Contaminated by Heavy Metals and Petroleum using Relocatable Soil Washing Equipment

  • Kim, Taeeung
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • We studied the on-site treatment of soil contaminated by heavy metals and petroleum was tested using relocatable soil washing equipment for greater remediation efficiency. Different combinations of pH and solid/liquid ratio were tested to determine the optimum balance, settling on values of 5 and 1:2, respectively. Next, soils containing Pb, Hg, and petroleum were further tested to assess the optimum number of washing cycles. The remediation efficiency of Pb and Hg in soil contaminated solely by heavy metals was 90.1% and 86.4% after three and two washings, respectively. The remediation efficiency of petroleum in soil contaminated solely by petroleum was 98.8% after one washing. When soil contaminated by both heavy metals and petroleum was cleaned, up to 91.0% of Pb, 86.9% of Hg, and 96.1% of petroleum was removed after two, one, and one washings, respectively. We conducted all remediation efficiencies and concentration reductions satisfied the standard threshold for soil contamination in South Korea.