• Title/Summary/Keyword: setpoint

Search Result 102, Processing Time 0.023 seconds

Development of an Algorithm for Searching Optimal Temperature Setpoint for Lettuce in Greenhouse Using Crop Growth Model (작물생장모델을 이용한 상추의 온실 최적설정온도 탐색 알고리즘의 개발)

  • 류관희;김기영;김희구;채희연
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.445-452
    • /
    • 1999
  • This study was conducted to develop a searching algorithm for optimal daily temperature setpoint greenhouse. An algorithm using crop growth and energy models was developed to determine optimum crop growth environment. The results of this study were as follows: 1. Mathematical models for crop growth and energy consumption were derived to define optimal daily temperature setpoint. 2. Optimum temperature setpoint, which could maximize performance criterion, was determined by using Pontryagin maximum principle. 3. Dynamic control of daily temperature using the developed algorithm showed higher performance criterion than static control with fixed temperature setpoint. Performance criteria for dynamic control models were with simulated periodic weather data and with real weather data, increased by 48% and 60%, respectively.

  • PDF

Control Methods of the VAV Air Handling Unit for the Required Outdoor Air Demand (변풍량 공조시스템의 요구외기량 확보를 위한 제어방식)

  • Han, Do-Young;Joo, Young-Duk;Kim, Jin;Lee, Jun-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.203-209
    • /
    • 2003
  • Control algorithms of an air handling unit by using the mixing box plenum pressures were developed and verified by experiments. Control algorithms developed for this study were the setpoint algorithms for the outdoor damper position, the outdoor/fixed plenum pressure, and the return/exhaust plenum pressure. The outdoor/fixed plenum pressure setpoint was used to control the bypass damper position, and the return/exhaust plenum pressure setpoint was used to control the return fan speed. Experimental results showed the good control of the required outdoor air demand. Therefore, setpoint algorithms developed for this study may effectively be applied for the control of the VAV air handling unit.

Control Algorithms of a Condensing Gas Boiler (응축형가스보일러의 제어알고리즘)

  • Han, Do-Young;Kim, Sung-Hak
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.399-404
    • /
    • 2008
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, the effective control of the system is necessary. In this study, control algorithms of a condensing gas boiler were developed. Control algorithms are composed of the setpoint algorithm and the control algorithm. The setpoint algorithm consists of the supply water temperature setpoint algorithm and the pump setpoint algorithm. The control algorithm consists of the gas valve control algorithm and the blower control algorithm. In order to analyse the performance of control algorithms, dynamic models of a condensing gas boiler system were used. Simulation results showed that control algorithms developed for this study may be practically applied to the condensing gas boiler.

  • PDF

The High-side Pressure Algorithm by using a Least Square Method and a Proportional Logic (최소제곱법과 비례로직을 이용한 시스템고압 알고리즘)

  • Han, Do-Young;Noh, Hee-Jeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.16-21
    • /
    • 2008
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of $CO_2$'s unique properties as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. High-side pressure algorithms, which were composed of the pressure setpoint algorithm and the pressure setpoint reset algorithm, were developed. Pressure setpoint algorithms, by using a neural network and by using a least square method, were developed and compared. Pressure setpoint reset algorithms, by using a fuzzy logic and by using a proportional logic, were also developed and compared. Simulation results showed that a least square method was more useful than a neural network for the pressure setpoint algorithm. And a proportional logic was more practical than a fuzzy logic for the pressure setpoint reset algorithm.

  • PDF

Reducing Peak Cooling Demand Using Building Precooling and Modified Linear Rise of Indoor Space Temperature (건물예냉과 실내온도의 선형상승에 의한 피크냉방수요 저감)

  • Lee, Kyoung-Ho;Yang, Seung-Kwon;Han, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.86-96
    • /
    • 2010
  • The paper describes development and evaluation of a simple method for determining gradient of modified linear setpoint variation to reduce peak electrical cooling demand in buildings using building precooling and setpoint adjustment. The method is an approximated approach for minimizing electrical cooling demand during occupied period in buildings and involves modified linear adjustment of cooling setpoint temperature between $26^{\circ}C$ and $28^{\circ}C$. The gradient of linear variation or final time of linear increase is determined based on the cooling load shape in conventional cooling control having a constant setpoint temperature. The potential to reduce peak cooling demand using the simple method was evaluated through building simulation for a calibrated office building model considering four different weather conditions. The simple method showed about 30% and 20% in terms of reducing peak cooling demand and chiller power consumption, respectively, compared to the conventional control.

Performance Analysis of the High-side Pressure Reset Algorithm for a $CO_2$ Air-conditioning System ($CO_2$ 에어컨 시스템을 위한 고압재설정알고리즘의 성능분석)

  • Han, Do-Young;Noh, Hee-Jeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.393-398
    • /
    • 2008
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of the unique property of a $CO_2$ as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the efficient operation. The high-side pressure algorithm being composed of the pressure setpoint algorithm and the pressure setpoint reset algorithm was developed. The pressure setpoint algorithm, by using a least square method, was developed. The pressure setpoint reset algorithm, by using a fuzzy logic and by using a proportional logic, was also developed and compared. Simulation results showed that a proportional logic was more practical than a fuzzy logic for the pressure setpoint reset algorithm.

  • PDF

The EEV Control of the Multi-type Air-conditioning System by using a Fuzzy Logic Superheat Temperature Setpoint Reset Algorithm (퍼지로직 과열도 재설정 알고리즘을 사용한 멀티형 냉방시스템의 전자팽창밸브 제어)

  • 한도영;이상원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.382-388
    • /
    • 2003
  • Refrigerant flow rates of the multi-type air-conditioning system can be regulated by electronic expansion valves (EEV). The performance of the multi-type air-conditioning system may be improved by lowering the superheat at the compressor suction side. In this study, a superheat temperature setpoint reset algorithm was developed by using fuzzy logics, and a PI algorithm was applied to control the superheat temperature near setpoints. Experimental results showed energy savings and stable operations at a multi-type air-conditioning system. Therefore, the developed setpoint reset algorithm may be effectively used for the EEV superheat temperature control of the multi-type air-conditioning system.

OPΔT and OTΔT Trip Setpoint Generation Methodology (OPΔT 및 OTΔT트립설정치의 생산방법)

  • Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.106-115
    • /
    • 1984
  • Core safety limits define reactor operating conditions and parameters that will assure fuel rod and reactor system's integrity. Limiting safety system settings (LSSS) programmed into reactor protection system (RPS) then ensure a rapid reactor trip to prevent or suppress conditions which might violate the core safety limits. Generation of the LSSS must properly take into account uncertainties in both calculated and measured parameters in order to assure, with an appropriate degree of confidence, that the RPS will protect the core safety limits. Reviewed in this report are Westinghouse RPS setpoint generation philosophy, methodology of safety limit development and LSSS generation procedure. The Westinghouse RPS trip setpoint generation methodology has been established based on the calculation of core safety limits and the selection of LSSS allowing appropriate uncertainties in a conservative manner. Such conservative values of setpoint assure a high degree of core protection against fuel melting and occurrence of DNB.

  • PDF

Local Anodization on Si surface Using Scanning Probe Microscope; Effects of Tip Voltage, Deflection Setpoint, and Tip Velocity on Line Height (주사탐침현미경을 이용한 Si 표면 국부 산화피막 형성시 선 높이에 대한 탐침 전위, 편향 셋포인트, 탐침 속도의 영향)

  • Kim Chang-Hwan;Choi Jeong-Woo;Shin Woon-Sup
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.2
    • /
    • pp.84-88
    • /
    • 2006
  • The effects of tip voltage, deflection setpoint, and tip velocity on height of $SiO_2$ line drawn by local anodization on Si wafer using scanning probe microscope were investigated. No local anodization was detected at smaller than -3 V of tip voltage. The line height increased at rate of 0.47 nm/V when the tip voltage is stronger than -3 V at $1{\mu}m/s$ tip velocity. From deflection setpoint, mechanical force between tip and substrate could be calculated and the threshold farce was $12\sim18nN$. The height of anodized $SiO_2$ lines is independent of the magnitude of force above the threshold force. The line height decreased as increasing the tip velocity and limited to 0.7 nm at -5 V tip voltage.

Boiler Supply Water Temperature Setting by Outside Air Temperature and Return Water Temperature (외기온도와 환수온도를 이용한 보일러의 공급수온도설정)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.161-166
    • /
    • 2009
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a boiler unit, the effective operation is necessary. In this study, the supply water temperature algorithm of a condensing gas boiler was developed. This includes the setpoint algorithm and the control algorithm of the supply water temperature. The setpoint algorithm was developed by the fuzzy logic and the control algorithm was developed by the proportional integral algorithm. In order to analyse the performance of the supply water temperature algorithm, the dynamic model of a condensing gas boiler system was used. Simulation results showed that the supply water temperature algorithm developed for this study may be practically applied for the control of the condensing gas boiler.

  • PDF