• Title/Summary/Keyword: servo drive

Search Result 407, Processing Time 0.028 seconds

Current Equation Loop Design of Muti-channel Direct Drive Valve Actuation (다중채널 직접구동 엑츄에이터의 구동전류 동일화 루프 설계)

  • Nam, Yoonsu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.162-169
    • /
    • 2000
  • A Direct Drive Valve(DDV) hydraulic actuation system which is commonly used as an aircraft's control surface driving actuator has multi-loop control structure to ensure its safety operation. However, because of not perfect matching of one self channel characteristics with the others, the servo valve driving current of each channel can be widely different. Therefore, the long-time use of DDV actuator without any correction of these channel current offsets will cause the problem of performance or life expectancy degradation due to unwanted heats in the linear motor. A current equalization loop structure which can minimizes current offsets between channels is introduced and designed. The performance of the current equalization loop is investigated and verified through the analytic and experimental ways.

  • PDF

Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method (해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계)

  • Lee, S.R.;Choi, H.Y.;Moon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.507-514
    • /
    • 2001
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.

  • PDF

TMR Contribution Analysis of Spindle-Disk System Vibration for the High-Density Hard Disk Drive of 80GB/Platter (80GB/PLATTER 하드 디스크 드라이브 설계를 위한 스핀들-디스크 시스템 진동의 TMR 기여도 분석)

  • 강성우;한윤식;오동호;황태연;김명업
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.58-64
    • /
    • 2001
  • An investigation of the TMR(Track Misregistration) requirements to achieve the capacity of 80GBytes/Platter in 7200rpm disk drive system is reported. This paper also gives an overview of the PES(Position Error Signal) characteristics in the 57,500TPI disk drive to estimate the required 95,000TPI-system PES. The TMR measured by PES are presented and decomposed in order to identify the portions and their contributions of the spindle-disk system vibration and HSA(Head-Stack-Assembly) system vibration respectively. A comprehensive review on the servo system is also presented to provide the practical limits of the modem servo architecture into TMR budget design. The decomposed PES energy distribution shows that the spindle-disk pack vibration is one of the top-ranking sources of the total TMR budget and its percentage contribution is about 50% considering all the other TMR sources.

  • PDF

Pull-in Behavior Analysis in an Optical Disk Drive using Phase Plane and the Evaluations of Effecting Parameters for it (위상평면을 이용한 광디스크 트랙 끌어들임의 동적 해석 및 영향인자의 평가)

  • 최진영;박태욱;양현석;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.894-899
    • /
    • 2004
  • In this paper, the track pull-in behavior analyses in an optical disk drive (ODD) using plane phase is treated and the parameters affecting it are discussed. Track pull-in is the track capture procedure to do track following control and it is key factor to increase data transfer rate. Simulation method, Runge-Kutta method to solve nonlinear equation, is used to evaluate the track pull-in conditions, and the real servo loop parameters are applied in this process to get the more real condition. Finally, the comments for the acquired results are discussed briefly.

  • PDF

Robust Tracking Control of Optical Disk Drive Using QFT (QFT를 이용한 광디스크 드라이브의 강건 트랙킹 제어)

  • Jun, Hong-Gul;Choi, Jin-Young;Kim, Dae-Hyun;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.440-445
    • /
    • 2000
  • Robust tracking controller of optical disk drive(ODD) is designed using quantitative feedback theory(QFT). Nominal plant model is identified from real system through modal test. Uncertainties and control performance of tracking servo are specified, and robust controller satisfying these specifications is designed in the QFT framework. To verify the performances of designed controller, experiment are performed in a digital signal processor(DSP) environment, and experimental results are compared with simulations.

  • PDF

Force Control of Electro-Hydraulic Servo System using Direct Drive Valve for Pressure Control (압력제어용 직동 밸브를 이용한 전기.유압 서보시스템의 힘 제어)

  • Lee C.D.;Lee J.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.3
    • /
    • pp.14-19
    • /
    • 2004
  • The Direct Drive Valve used in this study contains a pressure-feedback-loop in itself, then it can eliminate nonlinearity such as the square-root-term in flow rate calculation and the change of bulk modulus of hydraulic oil. In this study, assuming that the dynamic characteristic of the DDV is modelled as a first order lag system, an parameter identification method using the input data and the output data is applied to obtain DDV's mathematical model. Then, a state feedback controller was designed to implement the force control of hydraulic system, and the control performance was evaluated.

  • PDF

Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method (컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method (컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계)

  • Lee, Seong-Rae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1719-1726
    • /
    • 2004
  • Direct drive servovalve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the DC motor. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

Microprocessor-Based Vector Control System for Induction Motor Servo- Drive (유도전동기 서보운전을 위한 마이크로프로세서-벡터 제어 시스템)

  • 김광헌;김영렬;원충연;원종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1218-1229
    • /
    • 1991
  • The time optimal position control design can be repeatedly taken from the initial state of a dynamic system to a desired one as fast as possible in the industrial drives. In this case, an induction machine parameters will vary due to temperature, frequency, and saturation effects. In particular, the rotor resistance changes critically with temperature and frequency. These changes affect the command values of the stator current components and slip speed. There is a mismatch between the commanded variables and actual ones of the induction motor drive, and this situation leads to coupling of the vector controller from the plant, i.e. the induction motor . Consequences of such a coupling include the initiation of oscillations of the rotor flux and unsuitable switching of electromagnetic torque for the induction motor servo drive. Therefore, this paper describes a rotor resistance parameter compensating method for the induction motor, And the validity of the proposed design method is confirmed by simulation studies and experiment results.

  • PDF

Classical Controller Design of Direct Drive Servo Valve Using Analytical Bode Method (해석적 Bode 방법에 의한 직접구동형서보밸브의 고전적 제어기 설계)

  • Lee, Seong-Rae;Choe, Hyeon-Yeong;Mun, Ui-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.754-763
    • /
    • 2002
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the classical controller is designed using the analytical Bode method.