• Title/Summary/Keyword: serpentine

Search Result 224, Processing Time 0.02 seconds

Study on Revision of Minerals HSK Code of Korea (한국의 광산물 HSK Code 개정방안 연구)

  • Lee, Hwa Suk;Kim, Yu Jeong
    • Mineral and Industry
    • /
    • v.27
    • /
    • pp.8-15
    • /
    • 2014
  • In this study, a proposal for revision of HSK Code was established on legally designated minerals and national stockpile minerals. It is difficult to exactly identify trade balances of minerals, such as lithium ore, rare earth ore, serpentine, kidney stone in legally designated minerals and ingot of indium, ferro-tungsten, ingot of antimony, granule of selenium, gallium, lanthanum oxide, cerium carbonate in national stockpile minerals because HSK Codes of them were not allocated separately. Furthermore, specific use, standard, component, type of products cannot be exactly identified in current HSK Code system. Therefore, it is makes rule to separately manage minerals which were managed by government such as legally designated minerals and national stockpile minerals. However, a proposal for revision of HSK Code system was established to comply with international standard(HS Code) and the items over a certain size(amounts : over 50 mil.$, volumes : over 5000 ton) were selected as revised subjects. Moreover hierarchies between HSK Codes were considered.

  • PDF

Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance (냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구)

  • Cho, Kee-Hyeon;Ahn, Ho-Seon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this study, we investigated the hydrodynamic and thermal performance of constructal architectures on the basis of the mass flow rates for a given pressure drop, and we determined the thermal resistance and flow uniformity. The five flow configuration used in this study were the first construct with optimized hydraulic diameter, the second construct with optimized hydraulic diameter, the first construct with non-optimized hydraulic diameter, second construct with non-optimized hydraulic diameter, and a serpentine configuration. The results of our study suggest that the best fluid-flow structure is the second constructal structure with optimized constructal configurations. We also found that in the case of the optimized structure of cooling plates, the heat transfer was remarkably higher and the pumping power was significantly lower than those of traditional channels.

Anatomical Observation of Leaf of Gerbera hybrida Hort. Injured by Liriomyza trifolii (아메리카잎굴파리에 의한 거베라 피해잎의 조직학적 관찰)

  • Chung, Yong Mo;Kim, Jin Ki;An, Dong Chun;Been, Chul Gu;Lee, Dong Woo;Sohn, Hung Dae;Kwon, Oh Chang
    • Horticultural Science & Technology
    • /
    • v.17 no.4
    • /
    • pp.485-488
    • /
    • 1999
  • This study was conducted to obtain a basic information on the structural and histological characteristics of Gerbera hybrida Hort. leaf injured by american serpentine leafminer (ASL), Liriomyza trifolii, by using light and scanning electron microscope (SEM). Based on the anatomical observation of leaf blade injured by L. trifolii, the injury process could be divided into three stages. In the initial stage, the punctured tiny holes where ASL layed eggs after suction in the upperside of leaf were observed in the palisade parenchyma. In the middle stage, the hatched larvae made mines in the palisade parenchyma only. In the final stage, the mature larvae grew up making the mines bigger, and just before going out from the epidermis, it injured the inside of leaf containing one layer palisade parenchyma and two layers of spongy parenchyma.

  • PDF

Study on Microbiochip for Buccal Cell Lysis and DNA Purification (상피세포 시료 전처리용 마이크로바이오칩에 관한 연구)

  • Ha, Seung-Mo;Cho, Woong;Ahn, Yoo-Min;Hwang, Seung-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1785-1791
    • /
    • 2010
  • This paper describes a separable microfluidic device fabricated with PDMS (polydimethylsiloxane) and glass. The device is used for sample preparation involving cell lysis and the DNA purification process. The cell lysis was performed for 2 min at $80^{\circ}C$ in a serpentine-type microreactor ($20 {\mu}l$) using a Au microheater that was integrated with a thermal microsensor on a glass substrate. The DNA that was mixed with other residual products during the cell lysis process was then filtered through a new filtration system composed of microbeads (diameter: $50 {\mu}m$) and PDMS pillars. Since the entire process (sample loading, cell lysis reaction, DNA purification, and sample extraction) was performed within 5 min in a microchip, we could reduce the sample preparation time in comparison with that for the conventional methods used in biochemistry laboratories. Finally, we verified the performance of the sample preparation chip by conducting PCR (polymerase chain reaction) analysis of the chip product.

Thermal managing effects by cooling channels on performance of a PEMFC (냉각채널 열관리에 따른 고분자연료전지의 성능영향 연구)

  • Sohn, Young-Jun;Kim, Min-Jin;Park, Gu-Gon;Kim, Kyoung-Youn;Lee, Won-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.373-373
    • /
    • 2009
  • Relative humidity, membrane conductivity and water activity are critical parameters of polymer electrolyte membrane fuel cells (PEMFC) for high performance and reliability. These parameters are closely related with temperature. Moreover, the ideal values of these parameters are not always identical along the channels. Therefore, the cooling channel design and its operating condition should be well optimized along the all location of the channels. In the present study, we have performed a numerical investigation on the effects of cooling channels on performance of a PEMFC. Three-dimensional Navier-Stokes equations are solved with the energy equation including heat generated by the electrochemical reactions in the fuel cell. The present numerical model includes the gas diffusion layers (GDL) and serpentine channels for both anode and cathode gas flows, as well as cooling channels. To accurately predict the water transport across the membrane, the distribution of water content in the membrane is calculated by solving a nonlinear differential equation with a nonlinear coefficient, i.e., the water diffusivity which is a function of water content as well as temperature. Main emphasis is placed on the heat transfer between the solid bipolar plate and coolant flow. The present results show that local current density is affected by cooling channels due to the change of the oxygen concentration and the membrane conductivity as well as the water content. It is also found that the relative humidity is influenced by the generated water and the gas temperature and thus it affects the distribution of fuel concentration and the conductivity of the membrane, ultimately fuel cell performance. Unit-cell experiments are also carried out to validate the numerical models. The performance curves between the models and experiments show reasonable results.

  • PDF

Ore Minerals, Fluid Inclusions and Stable Isotopes of the Yucheon Bismuth Deposits, Korea (류천(柳川) 창연광상(蒼鉛鑛床) 광석광물(鑛石鑛物), 유체포유물(流體包有物) 및 안정동위원소(安定同位元素))

  • Lee, Hyun Koo;Yoo, Bong-Cheal;Kim, Sang Jung
    • Economic and Environmental Geology
    • /
    • v.29 no.2
    • /
    • pp.139-150
    • /
    • 1996
  • The Yucheon Bi deposits at Cheongha, Gyeongsangbugdo, is of a middle Paleogene (49 Ma) vein type, and is hosted in sandstone and shale of Banyawal formation in Cretaceous age. Based on mineral paragenesis, vein structure and mineral assemblages, two minera1ization stages were distinguished. The stage I consists of quartz with small amount of chlorite, pyrite, epidote, hal1oysite, vermiculite, serpentine and rutile associated with sericitization. The stage II is characterized by Bi minera1ization such as bismuthinite, Bi-Cu-Pb-S mineral, tetradymite, native gold, pyrite, pyrrhotite, arsenopyrite, wolframite, rutile, hematite, sphalerite, chalcopyrite, galena with alteration of sericite, chlorite, K-feldspar, albite and epidote. Fluid inclusion data indicate that fluid temperature and NaCl equivalent wt.% salinity range from 431 to $150^{\circ}C$ and from 19.2 to 0.18wt.% in the stage II. Evidence of boiling during the base-metal minera1ization indicates pressures 241 to 260 bars. Sulfur fugacity($-log\;f_{S2}$) deduced by mineral assemblages and compositions ranges from 5.1 to 5.7atm in early stage, from > 8.4 atm in middle stage and from 13.5 to 19.3 atm in late stage. It suggests that complex histories of progressive coo1ing, dilution and boiling were occurred by the mixing of the fluids. The ${\delta}^{34}S$, ${\delta}^{18}O$ and ${\delta}D$ data range from 2.5 to 3.9%, -0.5 to -4.1% and -29.7 to -47%, respectively. It indicated that hydrothermal fluids may be magmatic origin with boiling and mixing of meteoric water increasing paragenetic time.

  • PDF

Design and Fabrication of Mold Insert for Injection Molding of Microfluidic tab-on-a-chip for Detection of Agglutination (응집반응 검출을 위한 미세 유체 Lab on a chip의 사출성형 금형 인서트의 디자인 및 제작)

  • Choi, Sung-Hwan;Kim, Dong-Sung;Kwon, Tai-Hun
    • Transactions of Materials Processing
    • /
    • v.15 no.9 s.90
    • /
    • pp.667-672
    • /
    • 2006
  • Agglutination is one of the most commonly employed reactions in clinical diagnosis. In this paper, we have designed and fabricated nickel mold insert for injection molding of a microfluidic lab-on-a-chip for the purpose of the efficient detection of agglutination. In the presented microfluidic lab-on-a-chip, two inlets for sample blood and reagent, flow guiding microchannels, improved serpentine laminating micromixer(ISLM) and reaction microwells are fully integrated. The ISLM, recently developed by our group, can highly improve mixing of the sample blood and reagent in the microchannel, thereby enhancing reaction of agglutinogens and agglutinins. The reaction microwell was designed to contain large volume of about $25{\mu}l$ of the mixture of sample blood and reagent. The result of agglutination in the reaction microwell could be determined by means of the level of the light transmission. To achieve the cost-effectiveness, the microfluidic lab-on-a-chip was realized by the injection molding of COC(cyclic olefin copolymer) and thermal bonding of two injection molded COC substrates. To define microfeatures in the microfluidic lab-on-a-chip precisely, the nickel mold inserts of lab-on-a-chip for the injection molding were fabricated by combining the UV photolithography with a negative photoresist SU-8 and the nickel electroplating process. The microfluidic lab-on-a-chip developed in this study could be applied to various clinical diagnosis based on agglutination.

Effect of Applied Voltage Bias on Electrochemical Migration in Eutectic SnPb Solder Alloy

  • Lee, Shin-Bok;Jung, Ja-Young;Yoo, Young-Ran;Park, Young-Bae;Kim, Young-Sik;Joo, Young-Chang
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.282-285
    • /
    • 2007
  • Smaller size and higher integration of electronic systems make narrower interconnect pitch not only in chip-level but also in package-level. Moreover electronic systems are required to operate in harsher conditions, that is, higher current / voltage, elevated temperature / humidity, and complex chemical contaminants. Under these severe circumstances, electronic components respond to applied voltages by electrochemically ionization of metals and conducting filament forms between anode and cathode across a nonmetallic medium. This phenomenon is called as the electrochemical migration. Many kinds of metal (Cu, Ag, SnPb, Sn etc) using in electronic packages are failed by ECM. Eutectic SnPb which is used in various electronic packaging structures, that is, printed circuit boards, plastic-encapsulated packages, organic display panels, and tape chip carriers, chip-on-films etc. And the material for soldering (eutectic SnPb) using in electronic package easily makes insulation failure by ECM. In real PCB system, not only metals but also many chemical species are included. And these chemical species act as resources of contamination. Model test systems were developed to characterize the migration phenomena without contamination effect. The serpentine-shape pattern was developed for analyzing relationship of applied voltage bias and failure lifetime by the temperature / humidity biased(THB) test.

Original Rocks of the Talc Ore Deposits and their Steatitization in the Yesan Area, Choongnam, Korea (충남 예산지구 활석광상의 기원암과 활석화작용)

  • Woo, Young-Kyun;Lee, Dong-Woo
    • Journal of the Korean earth science society
    • /
    • v.22 no.6
    • /
    • pp.548-557
    • /
    • 2001
  • Ultramafic rocks in the Yesan talc ore deposits area are unknown age plutonic rocks which intruded PreCambrian Yoogoo gneiss, and were intruded by Jurassic biotite granite, and Cretaceous acidic and mafic dykes. The ultramafic rocks consist mainly of serpentinite with some amphibolite and talc ore body. The serpentinites are divided 5 rock types (S1${\sim}$S5) on the basis of the developed degree of serpentine phenocrysts and layerings. It seems that the original rocks of the serpentinites were co-magmatic peridotites (dunite and pyroxene peridotite). Main serpentinization from the original rocks was occurred during amphibolite facies regional metamorphism in Choongnam area which Yoogoo gneiss was affected. Main steatitization from the serpentinites was hydrothermal alteration by ascended hydrothermal fluid through crush zones.

  • PDF

Comparison between CFD Analysis and Experiments According to Various PEMFC Flow-field Designs

  • Lee, Kang-In;Lee, Se-Won;Park, Min-Soo;Cho, Yong-Hun;Cho, Yoon-Hwan;Chu, Chong-Nam;Sung, Yung-Eun
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in five kinds of flow-field designs, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, a single cell test was carried out to obtain the performance values. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. The single serpentine configuration gave the highest performance because of the high pressure difference magnitudes of the inlet/outlet. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.