• Title/Summary/Keyword: serial test

Search Result 343, Processing Time 0.025 seconds

Full-Custom Design of a Serial Peripheral Interface Circuit for CMOS RFIC Testing (CMOS RF 집적회로 검증을 위한 직렬 주변 인터페이스 회로의 풀커스텀 설계)

  • Uhm, Jun-Whon;Lee, Un-Bong;Shin, Jae-Wook;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.68-73
    • /
    • 2009
  • This paper presents an easily modifiable structure of a serial peripheral interface (SPI) that is suitable for efficient testing of CMOS RF integrated circuits. The proposed SPI Is designed so that the address size and the accompanying software can be easily adjusted and modified according to the requirements and complexity of RF IC's under development. The hardware architecture and software algorithm to achieve the flexibility are described. The proposed SPI is fabricated in $0.13{\mu}m$ CMOS and successfully verified experimentally with a 2.7GHz fractional-N delta-sigma frequency synthesizer as a device under test.

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

Ground Test and Evaluation of a Flight Control Systemfor Unmanned Aerial Vehicles

  • Suk, Jin-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.57-63
    • /
    • 2004
  • UAV(Unmanned Aerial Vehicle) has become one of the most popularmilitary/commercial aerial robots in the new millennium. In spite of all theadvantages that UAVs inherently have, it is not an easv job to develop a UAVbecause it requires very systematic and complete approaches in full developmentenvelop. The ground test and evaluation phase has the utmost importance in thesense that a well-developed system can be best verified on the ground. In addition,many of the aircraft crashes in the flight tests were resulted from the incompletedevelopment procedure. In this research, a verification procedure of the wholeairbome integrated system was conducted including the flight management system.An airbome flight control computer(FCC) senses the extemal environment from thepehpheral devices and sends the control signal to the actuating system using theassigned control logic and flight test strategy. A ground test station controls themission during the test while the downlink data are transferred from the flightmanagement computer using the serial communication interface. The pilot controlbox also applies additional manual actuating commands. The whole system wastested/verified on the wind-tunnel system, which gave a good pitch controlperformance with a preUspecified flight test procedure. The ground test systemguarantees the performance of fundamental functions of airbome electronic systemfor the future flight tests.

Near optimal production scheduling for multi-unit batch process

  • Kim, Kyeong-Sook;Cho, Young-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1718-1723
    • /
    • 1991
  • The determination of a production sequence is an important problem in a batch process operation. In this paper a new algorithm for a near optimal production sequence of N product in an M unit serial multiproduct batch process is proposed. The basic principle is the same as that of Johnson's algorithm for two-unit UIS system. Test results on a number of selected examples exhibit the superiority over previously reported results. In addition, a tabulation technique is presented to calculate the makespan of a given sequence of production for all processing units under UIS mode.

  • PDF

Modeling of The Ni-MH Battery Source and Development of The Charger.Discharger System (Ni-MH 전지전원의 모델링과 충.방전 장치 개발)

  • 김광헌;허민호;박영수;안재영;양승학;이일기
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.433-437
    • /
    • 1998
  • Equalize SOC of the cell which effect on the charge.discharge ability and the efficiency of the battery, through the charge.discharge characteristic test of the battery source, and develope the high efficiency charge.discharge system in the series HEV have a constant engine-generator output. For this, in this paper, establish the electrical model and the condition of high efficiency charge.discharge, and proposed the improvement method of charge.discharge characteristic in the battery source that consist of twenty Ni-MH cells connected serial/parallel

  • PDF

A hardware implementation of neural network with modified HANNIBAL architecture (수정된 하니발 구조를 이용한 신경회로망의 하드웨어 구현)

  • 이범엽;정덕진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.444-450
    • /
    • 1996
  • A digital hardware architecture for artificial neural network with learning capability is described in this paper. It is a modified hardware architecture known as HANNIBAL(Hardware Architecture for Neural Networks Implementing Back propagation Algorithm Learning). For implementing an efficient neural network hardware, we analyzed various type of multiplier which is major function block of neuro-processor cell. With this result, we design a efficient digital neural network hardware using serial/parallel multiplier, and test the operation. We also analyze the hardware efficiency with logic level simulation. (author). refs., figs., tabs.

  • PDF

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.1
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

A Study on the Test Strategy Based on SSA Technique for the Digital Circuit Boards in Production Line (SSA 기법에 기반한 생산조립라인의 디지털 부품 실장 PCB의 검사전략에 대한 연구)

  • Jung Yong-Chae;Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.4
    • /
    • pp.243-250
    • /
    • 2005
  • Test methodology is diversity by devices and the number of test pattern is tremendous because the digital circuit includes TTL and CMOS family ICs as well as high density devices such as ROM and RAM. Accordingly, the quick and effective test strategy is required to enhance the test productivity. This paper proposes the test strategy which is able to be applied efficiently to the diversity devices on the digital circuit board by analyzing the structure and characteristic of the digital device. Especially, this test strategy detects the faulted digital device or the faulted digital circuit on the digital board using SSA(Serial Signature Analysis) technique based on the polynomial division theory The SSA technique identifies the faults by comparing the reminder from good device with reminder from the tested device. At this time, the reminder is obtained by enforcing the data stream obtained from output pins of the tested device on the LFSR(Linear Feedback Shift Register) representing the characteristic equation. Also, the method to obtain the optimal signature analysis circuit is explained by furnishing the short bit input streams to the long bit input streams to the LFSR having 8, 12, 16, 20bit input/output pins and by analyzing the occurring probability of error which is impossible to detect. Finally, the effectiveness of the proposed test strategy is verified by simulating the stuck at 1 errors or stuck at 0 errors for several devices on typical 8051 digital board.

Cargo Inspection System Design and Boundary-Scan Test (화물 검색시스템 구현 및 Boundary_Scan Test)

  • Kim, Bong-Su;Kim, In-Su;Yoo, Sun-Won;Kim, Sung-Won;Lee, Sun-Wha;Yi, Yun;Han, Bum-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.197-200
    • /
    • 2002
  • We newly developed the procedures of X-ray Cargo inspection system with acquisition of multi-channel data, analog to digital converter and post logic circuit which is controlled by the FPGA. The IEEE1149.1 standard defines a four-wire serial interface(a fifth wire is optional)to access complex integrated circuits(ICs) such as PLD. This paper describes that Boundary_Scan test method applied to our home made cargo inspection system.

  • PDF

Development of UFC/DC Data Communication method for XKO-1 using RS-422 Bus (RS422 버스를 이용한 저속통제기 UFC/DC 데이터 통신 기법 개발)

  • 양승열;김영택
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • ASC(Avionics System Computer) was developed to control weapon delivery and navigation sensors, and to perform man-machine interface with pilots for XKO-1 aircraft. The data communications between ASC and UFC(Up Front Controller), DC(Data Concentrator) were implemented by RS422 serial data bus. Also, SCIL(Standard Computer Interface Library) was designed to facilitate control and management of the computer hardware resources and is embedded in the ASC. These structures have a merit of noise immunity and a reduction of wire harness for signal lines, and enable OFP(Operational Flight Program) programmers to use the SCIL easily without knowing hardware details. Manufactured system was on installed on XKO-1, and peformed for BIT(Built In Test) and interface test with UFC and DC. The test results show that it meets the system requirements.