• Title/Summary/Keyword: serial communication protocol

Search Result 128, Processing Time 0.032 seconds

Implementation of Global Position Location System using X.400 Protocol (X.400을 이용한 글로벌 위치확인 시스템 구현)

  • Lee, Myung-Eui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.178-182
    • /
    • 2005
  • The proposed system in this paper is designed to provide users with a means of global location information using Orbcomm satellite communication and X.400 protocol. The system's two-way data transmission capabilities allow users to track mobile or fixed objects anywhere in the world via Internet. This study utilizes the X.400 protocol, and the SIP(Serial Interface Protocol) and self defined control protocol to implement data communication link in this paper. Data processor board connected to SC(Subscriber Communicator) is also designed and implemented to interface with GPS receiver. The experimental results of the proposed global position location system is evaluated through real-time experiments, and we have confirmed it works well according to the protocol designed in this paper.

  • PDF

Implementation of Modular Multiplication and Communication Adaptor for Public Key Crytosystem (공개키 암호체계를 위한 Modular 곱셈개선과 통신회로 구현에 관한 연구)

  • 한선경;이선복;유영갑
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.7
    • /
    • pp.651-662
    • /
    • 1991
  • An improved modular multiplication algorithm for RSA type public key cryptosystem and its application to a serial communication cricuit are presented. Correction on a published fast modular multiplication algorithm is proposed and verified thru simulation. Cryptosystem for RS 232C communication protocol isdesigned and prototyped for low speed data exchange between computers. The system adops the correct algoroithm and operates successfully using a small size key.

  • PDF

Development of Embedded Vessel Monitoring System Using NMEA2000 (NMEA2000을 이용한 임베디드 선박 모니터링 시스템의 개발)

  • Lee, Chang-Ui;Kim, Dal-Yong;Yu, Yung-Ho;Shin, Ok-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.746-755
    • /
    • 2009
  • Recently, NMEA2000 became the de facto standard of the communication protocol for the instrument level network in vessels, and it is anticipated that most of the vessels will be equipped with the sensors and actuators based on this protocol. The conventional serial communication specifications such as RS-232, RS-485, or even NMEA0183 are single-talker/multiple-listener and interconnection among multiple sensors and/or actuators usually results in a bundle of wires. On the other hand, NMEA2000 is a true bus type(multiple-talker/multiple-listener) protocol and theoretically up to 256 instruments can be hot-plugged. With the advent of the protocol, it is necessary to consider a new type of monitoring system for the instruments in vessels: In most traditional serial communication environments, a dedicated monitor or user interface was necessary for each sensor or actuator as it was simply not easy to collect data in a single place. With NMEA2000, the collection of various types of information is simple. An embedded system can be employed to combine, to arrange and to display informations from various types of devices. Assuming that the actuators and sensors on a vessel are interconnected by NMEA2000 standard, we devise a tentative interactive vessel monitoring system in which the following 4 kinds of informations are collected and delivered: the navigation, engine, weather and tanks informations.

Vacuum Gauge Control System Using MSCC for PLS (MSCC를 이용한 가속기 진공장치 감시 시스템 개발)

  • Yoon, J.C.;Lee, T.Y.;Hang, J.Y.;Nam, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2169-2171
    • /
    • 2001
  • The vacuum gauge control system has been designed and implemented using multi-serial communication controllers (MSCC) for the 2.5 Gev storage ring at the Pohang Accelerator Laboratory (PAL). There are 20 Balzers vacuum gauges and 17 Granville-Phillips vacuum gauges at the storage ring. A MSCC have two RS485 (max speed 460.8Kbps) field network port, 8 channel serial communication ports (max speed 460.8Kbps) connected to gauge controller for serial communication control. 12 MSCCs are connected to a personal computer (PC) through the RS485 field network. The PC can automatically control the MSCCs by sending set of commands through the network. The commands specify the duration of the MODBUS protocol. Upon receiving a command from a PC running under Windows2000 through the network, the MSCC communicate through the serial output ports to gauge controller. In this paper, we describe control structure and scheme of the vacuum gauge control system.

  • PDF

Implementation of RS232C and TCP/IP Connection Device Using ARM Processor (ARM프로세서를 이용한 RS232C와 TCP/IP 접속장치의 구현)

  • Lee, Young-Jun;Han, Kyong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.635-638
    • /
    • 2002
  • In this paper, the connection device of RS232C and TCP/IP implementation using ARM processor and LINUX is proposed. Data interaction flash memory the multiple serial ports are transferred to ARM processor and the data are processed and formed into data packet for transfer via internet protocol. Packet flash memory Internet is decoded to extract the serial port data. The serial ports supports RS232C asynchronous protocol communication and control program is developed in GNU-C and installed in the on-board memory for packet conversion and control. The research result can be applied to terminal server, printer server and multiple serial ports equipments.

  • PDF

Fault Detection of BLDC Motor Using Serial Communication Based Parameter Estimation (시리얼 통신 기반 파라미터 추정에 의한 BLDC모터의 고장검출)

  • 서석훈;유정봉;우광준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.45-52
    • /
    • 2002
  • This paper presents fault detection scheme of Brushless DC(BLDC) motor drive system by estimating BLDC motor resistance using motor input and output data which is transmitted from data acquisition board to host computer over serial communication channel. Since communication time delay has a serious effect on performance, we use periodic and fixed communication protocol. Hence, the delay time is priory known. Simplified BLDC motor model and recursive least square algorithm is used for estimating motor resistance. By experiment result, we confirm the proposed scheme.

Development of the Serial Data Transmission System for Pneumatic Valve System Control

  • Kim, Dong-Soo;Choi, Byung-Oh;Seo, Hyun-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1152-1156
    • /
    • 2003
  • For pneumatic valve system control, we need a serial data transmission system with high speed and reliability for information interchange between main computer and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic valve system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid control valves. in addition, we developed a communication protocol for construction of rs-485 based multi-drop network and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. the field test results show that, even under high noise environment, the data transmission of 375kbps rate is possible up to 1,500meter without using repeater. In addition, the system developed in this research is easily to be extended for a communication network because of its modular structure.

  • PDF

Diagnosis and Improvement of mode transition delay in Linux 9bit serial communications (리눅스 9비트 시리얼통신에서 모드전환 지연원인의 분석과 개선)

  • Jeong, Seungho;Kim, Sangmin;Ahn, Heejune
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.6
    • /
    • pp.21-27
    • /
    • 2015
  • We analyze the problem that is occurring when using parity mode transformation required for 9 bit serial communication under Linux environment and propose the solution. The parity mode change is used for 9 bit serial communication in the Linux that by nature supports only 8 bit serial communication. delay (around OS tick) arises. Our analysis shows that the cause is minimum length of waiting time to transmit data remained in Tx FIFO buffers. A modified Linux serial driver proposed in this paper decreases the delay less than 1ms by using accurate time delaying. Despite various system communication interfaces, enormous existing standards and system have adopted RS-232 serial communication, and the part of them have communicated by 9bit serial.

Design and Implementation of an Interface Unit for Analysis of a CAN-Based Control System (CAN 기반 제어 시스템 분석을 위한 인터페이스 유닛 설계 및 구현)

  • Park, Byung-Ryuel;Jeong, Gu-Min;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.195-197
    • /
    • 2006
  • In this paper, an interface unit is designed to efficiently monitor transmission data in Controller Area Network(CAN)-based control systems. The CAN uses a serial multi master communication protocol that efficiently supports distributed real-time control with a very high level of data integrity, and communication speeds of up to 1Mbps. The interface unit is composed of a DSP controller which collects data on the CAN bus and transfers data to a personal computer via serial communication to save and display of interesting signals. The experimental system consists of three DSP controllers which represent electronic control units of a vehicle, an interface unit for analysing the data on the bus, and a graphic monitoring program coded on the Windows platform. The validity and the effectiveness of the proposed simple type of CAN interface unit are shown through the experimental results.

  • PDF

Industrial Communication Gateway Design of Communications Module Additive layer type (통신 모듈 적층형 산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Nam, Jae Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.133-136
    • /
    • 2019
  • Recently, many industrial devices are facing protocol compatibility problems with external monitoring and control systems. This paper designed an industrial communication gateway that can support the transformation of industrial communication protocol using multi-layered communication module. Industrial communication gateways have a structure that connects individual communication modules using rs485 serial communication to multiple layers. Each communication module consisted of analog data card, a digital data card LAN, and a CAN-enabled card. The main board processor used Atmega micro-processor, and the rs485 serial slot was placed to have a multi-layer communication module structure. These additive layer type communication modules support analog and digital I/O functions and LAN and CAN for wide use in industrial communication control and monitoring.

  • PDF