• 제목/요약/키워드: sequential separation

검색결과 71건 처리시간 0.028초

Sequential Separation of Main Components from Chicken Egg Yolk

  • Ahn, Dong-Uk;Lee, Sang-Hyun;Singam, Haribabu;Lee, Eun-Joo;Kim, Jae-Cherl
    • Food Science and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.189-195
    • /
    • 2006
  • A study was conducted to develop optimal conditions for a large-scale, sequential separation method for value-added components from egg yolk. Starting with liquid egg yolk, immunoglobulin Y (IgY), phospholipids, and neutral lipids were extracted sequentially using water, ethanol, and n-hexane. The remainder was yolk proteins. Adjusting the pH of diluted egg yolk to pH 5.0-5.2 decreased phospholipids content in the supernatant after centrifugation, which was very important for preventing clogging problem of ultrafiltration filters during the subsequent concentration step for IgY separation. Extraction of precipitants after centrifugation with four volumes of 100% ethanol once removed most of the phospholipids and the purity of phospholipids was more than 85% (wt.) after drying. The subsequent extraction of precipitant from ethanol extraction with four volumes of hexane 3 times removed neutral lipids almost completely and resulted in a high protein product with minimal lipids. The sequential separation method is considered to be advantageous for large-scale separations of many valuable components from egg yolk.

Thermodynamic Study of Sequential Chlorination for Spent Fuel Partitioning

  • Jinmok Hur;Yung-Zun Cho;Chang Hwa Lee
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.397-410
    • /
    • 2023
  • This study examined the efficacy of various chlorinating agents in partitioning light water reactor spent fuel, with the aim of optimizing the chlorination process. Through thermodynamic equilibrium calculations, we assessed the outcomes of employing MgCl2, NH4Cl, and Cl2 as chlorinating agents. A comparison was drawn between using a single agent and a sequential approach involving all three agents (MgCl2, NH4Cl, and Cl2). Following heat treatment, the utilization of MgCl2 as the sole chlorinating agent resulted in a moderate separation. Specifically, this method yielded a solid separation with 96.9% mass retention, 31.7% radioactivity, and 44.2% decay heat, relative to the initial spent fuel. In contrast, the sequential application of the chlorinating agents following heat treatment led to a final solid separation characterized by 93.1% mass retention, 5.1% radioactivity, and 15.4% decay heat, relative to the original spent fuel. The findings underscore the potential effectiveness of a sequential chlorination strategy for partitioning spent fuel. This approach holds promise as a standalone technique or as a complementary process alongside other partitioning processes such as pyroprocessing. Overall, our findings contribute to the advancement of spent fuel management strategies.

블라인드 동채널 신호 분리를 위한 순차적인 Joint Maximum Likelihood 알고리듬 (A Sequential Joint Maximum Likelihood Algorithm for Blind Co-Channel Signal Separation)

  • Inseon Jang;Park, Seungjin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2001
  • In this paper we consider a problem of blind co-channel signal separation, the goal of which is to estimate multiple co-channel digitally modulated signals using an antenna array. We employ the joint maximum likelihood estimation and present a sequential algorithm, which is referred to as sequential joint maximum likelihood (SJML) algorithm. It separates multiple co-channel signal on-line and converges fast in overdetermined noisy communication environment. And the computational complexity of SJML for M-QAM (M=8, 16, 64,...) signals is less expensive compared to the SLSP. Useful behavior of this algorithm are confirmed by simulations.

  • PDF

병렬화된 Chimera 격자 기법을 이용한 다단 로켓의 단분리 운동 해석 (Numerical Analysis on Separation Dynamics of Multi-stage Rocket System Using Parallelized Chimera Grid Scheme)

  • 고순흠;최성진;김종암;노오현;박정주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.47-52
    • /
    • 2002
  • The supersonic flow around multi-stage rocket system is analyzed using 3-D compressible unsteady flow solver. A Chimera overset grid technique is used for the calculation of present configuration and grid around the core rocket is composed of 3 zones to represent fins in the core rocket. Flow solver is parallelized to reduce the computation time, and an efficient parallelization algorithm for Chimera grid technique is proposed. AUSMPW+ scheme is used for the spatial discretization and LU-SGS for the time integration. The flow field around multi-stage rocket was analyzed using this developed solver, and the results were compared with that of a sequential solver The speed-up ratio and the efficiency were measured in several processors. As a result, the computing speed with 12 processors was about 10 times faster than that of a sequential solver. Developed flow solver is used to predict the trajectory of booster in separation stage. From the analyses, booster collides against core rocket in free separation case. So, additional jettisoning forces and moments needed for a safe separation are examined.

  • PDF

EUTECTIC(LiCl-KCl) WASTE SALT TREATMENT BY SEQUENCIAL SEPARATION PROCESS

  • Cho, Yung-Zun;Lee, Tae-Kyo;Choi, Jung-Hun;Eun, Hee-Chul;Park, Hwan-Seo;Park, Geun-Il
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.675-682
    • /
    • 2013
  • The sequential separation process, composed of an oxygen sparging process for separating lanthanides and a zone freezing process for separating Group I and II fission products, was evaluated and tested with a surrogate eutectic waste salt generated from pyroprocessing of used metal nuclear fuel. During the oxygen sparging process, the used lanthanide chlorides (Y, Ce, Pr and Nd) were converted into their sat-insoluble precipitates, over 99.5% at $800^{\circ}C$; however, Group I (Cs) and II (Sr) chlorides were not converted but remained within the eutectic salt bed. In the next process, zone freezing, both precipitation of lanthanide precipitates and concentration of Group I/II elements were preformed. The separation efficiency of Cs and Sr increased with a decrease in the crucible moving speed, and there was little effect of crucible moving speed on the separation efficiency of Cs and Sr in the range of a 3.7 - 4.8 mm/hr. When assuming a 60% eutectic salt reuse rate, over 90% separation efficiency of Cs and Sr is possible, but when increasing the eutectic salt reuse rate to 80%, a separation efficiency of about 82 - 86 % for Cs and Sr was estimated.

Sequential determination of $^{239,240}Pu,\;^{238}Pu,\;^{90}Sr$ and $^{241}Am$ Isotopes in Environmental Samples

  • Lee, Myung-Ho;Jo, Mi-Hyun;Park, Jong-Ho;Ahn, Hong-Joo;Lee, Chang-Heon;Song, Kyu-Seok
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2009년도 학술논문요약집
    • /
    • pp.407-408
    • /
    • 2009
  • In this work, a quantitative method of the sequential separation of $^{90}Pu,\;^{90}Sr$ and $^{241}Am$ nuclides was developed in environmental soil samples using by an anion exchange resin connected with a Sr Spec resin. The sequential methods of Pu, $^{90}Sr$ and $^{241}Am$ nuclides can reduce analysis cost and time. With the sequential methodupdated in this study, the activity concentrations of $^{239,240}Pu,\;^{90}Sr$ and $^{241}Am$ in the IAEA reference materials were close to the reference values reported by the IAEA.

  • PDF

Ergonomic Evaluation of Color Breakup in Field-Sequential Color Projection System

  • Shibate, Takashi;Kawai, Takashi;Kim, Sang-Hyun;Ukai, Kazuhiko
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.121-124
    • /
    • 2005
  • A field-sequential color projection system can display color images using panel. However, it suffers from a characteristic trichromatic separation known as "color breakup". The viewing of images exhibiting color breakup may cause visual fatigue and mental stress. In this study, the authors examine, from the standpoint of human factors, the objective and subjective symptoms that can result from the viewing of images with color breakup.

  • PDF

방사능 분석기술을 이용한 90Sr, 239,240Pu, 238Pu, 241Am 축차분리 (Sequential separation of 90Sr, 241Am, 239,240Pu and 238Pu by radioanalytical techniques)

  • 이명호;박경균;김종윤;박영재;김원호
    • 분석과학
    • /
    • 제18권6호
    • /
    • pp.469-474
    • /
    • 2005
  • 본 연구에서는 음이온 교환수지와 Sr-Spec 수지를 사용하여 토양중 $^{90}Sr$, $^{241}Am$ 및 Pu 동위원소들에 대하여 축차적으로 분리하는 정량법을 제시하였다. 플루토늄은 음이온 교환수지를 이용하여 분리하였고, 아메리슘 및 스트론튬은 옥살산 공침법 및 Sr-Spec 수지를 사용하여 순수 분리하였다. Pu 및 Am 동위원소는 알파 스펙트로메트리법으로 정량하였고, Sr-90은 액체섬광계수기를 사용하여 정량하였다. 본 연구에서 고찰된 $^{90}Sr$, $^{241}Am$ 및 Pu 동위원소 분석법을 IAEA 기준시료에 적용하여 분석법의 타당성을 검증하였다.

Interference-filter-based stereoscopic 3D LCD

  • Simon, Arnold;Prager, M. G.;Schwarz, S.;Fritz, M.;Jorke, H.
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.24-27
    • /
    • 2010
  • A novel stereo 3D LCD for passive interference filter glasses is presented. A demonstrator based on a standard 120Hz LCD was set up. Stereoscopic image separation was realized in a time-sequential mode using a LED-based scanning backlight with two complementary spectra. A stereo brightness of 3 cd/$m^2$ and a channel separation of 30:1 were achieved.