• Title/Summary/Keyword: sequential difference images

Search Result 26, Processing Time 0.02 seconds

Automatic Extraction of the Facial Feature Points Using Moving Color (색상 움직임을 이용한 얼굴 특징점 자동 추출)

  • Kim, Nam-Ho;Kim, Hyoung-Gon;Ko, Sung-Jea
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.55-67
    • /
    • 1998
  • This paper presents an automatic facial feature point extraction algorithm in sequential color images. To extract facial region in the video sequence, a moving color detection technique is proposed that emphasize moving skin color region by applying motion detection algorithm on the skin-color transformed images. The threshold value for the pixel difference detection is also decided according to the transformed pixel value that represents the probability of the desired color information. Eye candidate regions are selected using both of the black/white color information inside the skin-color region and the valley information of the moving skin region detected using morphological operators. Eye region is finally decided by the geometrical relationship of the eyes and color histogram. To decide the exact feature points, the PCA(Principal Component Analysis) is used on each eye and mouth regions. Experimental results show that the feature points of eye and mouth can be obtained correctly irrespective of background, direction and size of face.

  • PDF

Natural Course of Initially Non-Operated Cases of Acute Subdural Hematoma : The Risk Factors of Hematoma Progression

  • Son, Seong;Yoo, Chan Jong;Lee, Sang Gu;Kim, Eun Young;Park, Chan Woo;Kim, Woo Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.211-219
    • /
    • 2013
  • Objective : The objectives of the present study were to characterize the natural course of initially non-operated traumatic acute subdural hematoma (ASDH) and to identify the risk factors of hematoma progression. Methods : Retrospective analysis was performed using sequential computed tomography (CT) images maintained in a prospective observational database containing 177 ASDH cases treated from 2005 to 2011. Patients were allocated to four groups as followings; 136 (76.8%) patients to the spontaneous resolution group, 12 (6.8%) who underwent operation between 4 hours and 7 days to the rapid worsening group (RWG), 24 (13.6%) who experienced an increase of hematoma and that underwent operation between 7 and 28 days to the subacute worsening group (SWG), and 5 (2.8%) who developed delayed aggravation requiring surgery from one month after onset to the delayed worsening group (DWG). Groups were compared with respect to various factors. Results : No significant intergroup difference was found with respect to age, mechanism of injury, or initial Glasgow Coma Scale. The presence of combined cerebral contusion or subarachnoid hemorrhage was found to be a significant prognostic factor. Regarding CT findings, mixed density was common in the RWG and the SWG. Midline shifting, hematoma thickness, and numbers of CT slices containing hematoma were significant prognostic factors of the RWG and the SWG. Brain atrophy was more severe in the SWG and the DWG. Conclusion : A large proportion of initially non-operated ASDHs worsen in the acute or subacute phase. Patients with risk factors should be monitored carefully for progression by repeat CT imaging.

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

Application of Automated Microscopy Equipment for Rock Analog Material Experiments: Static Grain Growth and Simple Shear Deformation Experiments Using Norcamphor (유사물질 실험을 위한 자동화 현미경 실험 기기의 적용과 노캠퍼를 이용한 입자 성장 및 단순 전단 변형 실험의 예)

  • Ha, Changsu;Kim, Sungshil
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.233-245
    • /
    • 2021
  • Many studies on the microstructures in rocks have been conducted using experimental methods with various equipment as well as natural rock studies to see the development of microstructures and understand their mechanisms. Grain boundary migration of mineral aggregates in rocks could cause grain growth or grain size changes during metamorphism or deformation as one of the main recrystallization mechanisms. This study suggests improved ways regarding the analog material experiments with reformed equipment to see sequential observations of these grain boundary migration. It can be more efficient than the existing techniques and carry out an appropriate microstructure analysis. This reformed equipment was implemented to enable optical manipulation by mounting polarizing plates capable of rotating operation on a stereoscopic microscope and a deformation rig capable of experimenting with analog materials. The equipment can automatically control the temperature and strain rate of the deformation rig by microcontrollers and programming and can take digital photomicrographs with constant time intervals during the experiment to observe any microstructure changes. The composite images synthesized using images by rotated polarizing plates enable us to see more accurate grain boundaries. As a rock analog material, norcamphor(C7H10O) was used, which has similar birefringence to quartz. Static grain growth and simple shear deformation experiments were performed using the norcamphor to verify the effectiveness of the equipment. The static grain growth experiments showed the characteristics of typical grain growth behavior. The number of grains decreases and the average grain size increases over time. These case experiments also showed a clear difference between the growth curves with three temperature conditions. The result of the simple shear deformation experiment under the medium temperature-low strain rate showed no significant change in the average grain size but presented the increased elongation of grain shapes in the direction of about 53° regarding the direction perpendicular to the shearing direction as the shear strain increases over time. These microstructures are interpreted as both the plastic deformation and the internal recovery process in grains are balanced by the deformation under the given experimental conditions. These experiments using the reformed equipment represent the ability to sequentially observe changing the microstructure during experiments as desired in the tests with the analog material during the entire process.

Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease (관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성)

  • Lee, Duk-Young;Bae, Jin-Ho;Lee, Sang-Woo;Chun, Kyung-Ah;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Ha, Jeoung-Hee;Chae, Shung-Chull;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.473-480
    • /
    • 2005
  • Purpose: Adenosine myocardial perfusion SPECT has proven to be useful in the detection of coronary artery disease, in the follow up the success of various therapeutic regimens and in assessing the prognosis of coronary artery disease. The purpose of this study is to define the reproducibility of myocardial perfusion SPECT using adenosine stress testing between two consecutive Tc-99m sestaMIBI (MIBI) SPECT studies in the same subjects. Methods: Thirty patients suspected of coronary artery disease in stable condition underwent sequential Tc-99m MIBI SPECT studies using intravenous adenosine. Gamma camera, acquisition and processing protocols used for the two tests were identical and no invasive procedures were performed between two tests. Mean interval between two tests were 4.1 days (range: 2-11 days). The left ventricular wall was divided into na segments and the degree of myocardial tracer uptake was graded with four-point scoring system by visual analysis. Images were interpretated by two independent nuclear medicine physicians and consensus was taken for final decision, if segmental score was not agreeable. Results: Hemodynamic responses to adenosine were not different between two consecutive studies. There were no serious side effects to stop infusion of adenosine and side effects profile was not different. When myocardial uptake was divided into normal and abnormal uptake, 481 of 540 segments were concordant (agreement rate 89%, Kappa index 0.74). With four-grade storing system, exact agreement was 81.3% (439 of 540 segments, tau b=0.73). One and two-grade differences were observed in 97 segments (18%) and 4 segments (0.7%) respectively, but three-grade difference was not observed in any segment. Extent and severity scores were not different between two studios. The extent and severity scores of the perfusion defect revealed excellent positive correlation between two test (r value for percentage extent and severity score is 0.982 and 0.965, p<0.001) Conclusion: Hemodynamic responses and side effects profile were not different between two consecutive adenosine stress tests in the same subjects. Adenosine Tc-99m sestaMIBI SPECT is highly reproducible, and could be used to assess temporal changes in myocardial perfusion in individual patients.