• Title/Summary/Keyword: sequence images

Search Result 580, Processing Time 0.028 seconds

T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence

  • E-K. Jeong;Lee, S-H.;J-S. Suh;Y-Y wak;S-A. Shin;Y-K. Kwon;Y. Huh
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.1
    • /
    • pp.7-20
    • /
    • 1997
  • The mapping of the spin-spin relaxation time T2 in pixed-by-pixel was suggested as a quantitative diagnostic tool in medicine. Although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any misregistration of each pixel's signal for the fitting T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17∼20 msec can give the reliable T2 map.

  • PDF

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

Adaptive Enhancement Method for Robot Sequence Motion Images

  • Yu Zhang;Guan Yang
    • Journal of Information Processing Systems
    • /
    • v.19 no.3
    • /
    • pp.370-376
    • /
    • 2023
  • Aiming at the problems of low image enhancement accuracy, long enhancement time and poor image quality in the traditional robot sequence motion image enhancement methods, an adaptive enhancement method for robot sequence motion image is proposed. The feature representation of the image was obtained by Karhunen-Loeve (K-L) transformation, and the nonlinear relationship between the robot joint angle and the image feature was established. The trajectory planning was carried out in the robot joint space to generate the robot sequence motion image, and an adaptive homomorphic filter was constructed to process the noise of the robot sequence motion image. According to the noise processing results, the brightness of robot sequence motion image was enhanced by using the multi-scale Retinex algorithm. The simulation results showed that the proposed method had higher accuracy and consumed shorter time for enhancement of robot sequence motion images. The simulation results showed that the image enhancement accuracy of the proposed method could reach 100%. The proposed method has important research significance and economic value in intelligent monitoring, automatic driving, and military fields.

Robust Digital Watermarking Using Chaotic Sequence (카오스 시퀀스를 이용한 견고한 디지털 워터마킹)

  • 김현환;정기룡
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.630-637
    • /
    • 2003
  • This paper proposed a new watermarking algorithm using chaotic sequence instead of conventional M-sequence for protecting copyright to the author. Robustness and security is very important for watermarking process. We use multi-threshold value according to the human visual system for improving robustness of watermarking to each subband images coefficient differently after wavelet transform. And then, we embedded watermark image to original image by multi-watermark weights which are made by random sequence generator. We detect watermark image from the difference data which is made from each wavelet subband images. We also simulate the efficiency from the various possible attacks. Chaotic sequence is better than M-sequence, because the one is very easy to make sequence and the chaotic sequence is changed easy according to the initial value. So, the chaotic sequence has the better security than the conventional M-sequence.

Study on 2D Sprite *3.Generation Using the Impersonator Network

  • Yongjun Choi;Beomjoo Seo;Shinjin Kang;Jongin Choi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.7
    • /
    • pp.1794-1806
    • /
    • 2023
  • This study presents a method for capturing photographs of users as input and converting them into 2D character animation sprites using a generative adversarial network-based artificial intelligence network. Traditionally, 2D character animations have been created by manually creating an entire sequence of sprite images, which incurs high development costs. To address this issue, this study proposes a technique that combines motion videos and sample 2D images. In the 2D sprite generation process that uses the proposed technique, a sequence of images is extracted from real-life images captured by the user, and these are combined with character images from within the game. Our research aims to leverage cutting-edge deep learning-based image manipulation techniques, such as the GAN-based motion transfer network (impersonator) and background noise removal (U2 -Net), to generate a sequence of animation sprites from a single image. The proposed technique enables the creation of diverse animations and motions just one image. By utilizing these advancements, we focus on enhancing productivity in the game and animation industry through improved efficiency and streamlined production processes. By employing state-of-the-art techniques, our research enables the generation of 2D sprite images with various motions, offering significant potential for boosting productivity and creativity in the industry.

Three-Dimensional Reconselction using the Dense Correspondences from Sequence Images (연속된 영상으로부터 조밀한 대응점을 이용한 3차원 재구성)

  • Seo Yung-Ho;Kim Sang-Hoon;Choi Jong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.8C
    • /
    • pp.775-782
    • /
    • 2005
  • In case of 3D reconstruction from dense data in uncalibrated sequence images, we encounter with the problem for searching many correspondences and the computational costs. In this paper, we propose a key frame selection method from uncalibrated images and the effective 3D reconstruction method using the key frames. Namely, it can be performed on smaller number of views in the image sequence. We extract correspondences from selected key frames in image sequences. From the extracted correspondences, camera calibration process will be done. We use the edge image to fed dense correspondences between selected key frames. The method we propose to find dense correspondences can be used for recovering the 3D structure of the scene more efficiently.

FEASIBILITY ON GENERATING STEREO MOSAIC IMAGE

  • Noh, Myoung-Jong;Lee, Sung-Hun;Cho, Woo-Sug
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.201-204
    • /
    • 2005
  • Recently, the generation of panoramic images and high quality mosaic images from video sequences has been attempted by a variety of investigations. Among a matter of investigation, in this paper, left and right stereo mosaic image generation utilizing airborne-video sequence images is focused upon. The stereo mosaic image is generated by creating left and right mosaic image which is generated by front and rear slit having different viewing angle in consecutive video frame images. The generation of stereo mosaic image proposed in this paper consists of several processes: camera parameter estimation for each video frame image, rectification, slicing, motion parallax elimination and image mosaicking. However it is necessary to check the feasibility on generating stereo mosaic image as explained processes. Therefore, in this paper, we performed the feasibility test on generating stereo mosaic image using video frame images. In doing so, anaglyphic image for stereo mosaic images is generated and tested for feasibility check.

  • PDF

Geometric analysis of mobile mapping images sequence

  • Kang, Zhizhong;Zhang, Zuxun
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.183-185
    • /
    • 2003
  • Spatially referenced mobile mapping (MM) images contain rich information of man-made objects , e.g. road centerlines, buildings, light poles, traffic signs ,billboards and line trees etc. Therefore, the applications in transportation, urban 3D reconstruction, utility management are implemented increasingly. It’s a fundamental issue lies in MM image process that how to orient this image in the object space including interior orientation of camera and the exterior orientation of image. In this paper, the algorithm of automatic acquirement of DC (Digital Camera) parameters based on MM images is illustrated. And then, the mapping between image space and object space for MM images is described.

  • PDF

Distance Measurement Using a Single Camera with a Rotating Mirror

  • Kim Hyongsuk;Lin Chun-Shin;Song Jaehong;Chae Heesung
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.4
    • /
    • pp.542-551
    • /
    • 2005
  • A new distance measurement method with the use of a single camera and a rotating mirror is presented. A camera in front of a rotating mirror acquires a sequence of reflected images, from which distance information is extracted. The distance measurement is based on the idea that the corresponding pixel of an object point at a longer distance moves at a higher speed in a sequence of images in this type of system setting. Distance measurement based on such pixel movement is investigated. Like many other image-based techniques, this presented technique requires matching corresponding points in two images. To alleviate such difficulty, two kinds of techniques of image tracking through the sequence of images and the utilization of multiple sets of image frames are described. Precision improvement is possible and is one attractive merit. The presented approach with a rotating mirror is especially suitable for such multiple measurements. The imprecision caused by the physical limit could be improved through making several measurements and taking an average. In this paper, mathematics necessary for implementing the technique is derived and presented. Also, the error sensitivities of related parameters are analyzed. Experimental results using the real camera-mirror setup are reported.

A STUDY ON MAGNETIC RESONANCE IMAGING OF THE TEMPOROMANDIBULAR JOINT (악관절에 대한 자기 공명 영상의 연구)

  • Kim Hyung Sik;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.187-198
    • /
    • 1990
  • Examinations of the temporomandibular joints were performed on a 1.5 Tesla magnetic resonance (MR) system. An MR surface receiver coil 3 inch in diameter was placed on plastic frame, the patient's head being placed in the frame so that the coil was pressed against the temporal region. In taking advantage of the magnetic resonance imaging that has been studied briskly till now, author obtained the images of parasagittal and paracoronal planes about the temporomandibular joint by using MPGR (Multi-Planar Gradient Recalled), GRASS (Gradient Recalled Acquisition in the Steady State), and CSMEMP (Contiguous Slice Multiple Echo, Multi-Planar), that differ from the Spin Echo pulse sequence which the previous authors used. Five subjects with no symptoms of temporomandibular joint pain and dysfunction were studied. The plane images obtained by these methods were compared with those by Spin Echo pulse sequence. The results were as follows: 1. The optimal repetition times (TR) and echo times (TE) for T.M.J. image were; a. 400 msec and 18 msec in PMGR pulse sequence. b. 40 msec and 12 msec in GRASS pulse sequence. c. 700 msec and 30 msec in CSMEMP pulse sequence. d. 500 msec and 20 msec in Spin Echo pulse sequence. 2. When the MPGR pulse sequence was using, T2-weighted image was obtained in very short time. On the image of the paracoronal plane by GRASS pulse sequence, meniscus showed the moderate signal intensity, and the meniscus and its anteromedial, posterolateral attachments were observed definitely with gray color. 4. The signal intensity of Spin Echo pulse sequence was equal to that of CSMEMP pulse sequence, but the image by CSMEMP pulse sequence showed relatively lower level in its resolution.

  • PDF